Publications by authors named "Marco Capogni"

A national Inter-Laboratory Comparisons (ILCs) programme was organized in Italy in 2022 by the Italian National Institute of Ionizing Radiation Metrology (INMRI), belonging to ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development), under the auspices of the Ministry of Enterprises and Made in Italy (Mimit ex MiSe). Within this ILCs programme, six inter-laboratory comparisons were organized, including the ILC-2 which focused on activity measurements carried out with radionuclide calibrators commonly used in the nuclear medicine departments of the participants. The focus was on three short-lived radionuclides - Tc, F, Lu - commonly employed in nuclear medicine for both diagnostic and therapeutic purposes.

View Article and Find Full Text PDF

Molecular Radiation Therapy (MRT) is a valid therapeutic option for a wide range of malignancies, such as neuroendocrine tumors and liver cancers. In its practice, it is generally acknowledged that there is a need to evaluate the influence of different factors affecting the accuracy of dose estimates and to define the actions necessary to maintain treatment uncertainties at acceptable levels. The present study addresses the problem of uncertainty propagation in Y-PET quantification.

View Article and Find Full Text PDF

The Bureau International des Poids et Mesures (BIPM) is developing a new transfer instrument to extend its centralized services for assessing the international equivalence of radioactive standards to new radionuclides. A liquid scintillation counter using the triple/double coincidence ratio method is being studied and tested in the CCRI(II)-P1.Co-60 pilot study.

View Article and Find Full Text PDF

Interlaboratory exercises are a good tool to compare the response of different systems to the same quantity and to identify possible inconsistencies between them. One of the main goals of the EMPIR 19ENV01 traceRadon project is to harmonize radon flux measurements based on different systems and methodologies. In the framework of the traceRadon Project, two radon flux intercomparison campaigns were carried out in October 2021 at high and at low radon source areas.

View Article and Find Full Text PDF

In the last few years there has been an increasing interest in the measurement of the absorbed dose from radionuclides, with special attention devoted to molecular radiotherapy treatments. In particular, the determination of the absorbed dose from beta emitting radionuclides in liquid solution poses a number of issues when dose measurements are performed using thermoluminescent dosimeters (TLD). Finite volume effect, i.

View Article and Find Full Text PDF

Background: the gamma-emitting radionuclide Technetium-99m (Tc) is still the workhorse of Single Photon Emission Computed Tomography (SPECT) as it is used worldwide for the diagnosis of a variety of phatological conditions. Tc is obtained from Mo/Tc generators as pertechnetate ion, which is the ubiquitous starting material for the preparation of Tc radiopharmaceuticals. Mo in such generators is currently produced in nuclear fission reactors as a by-product of U fission.

View Article and Find Full Text PDF

Background: PET/CT has recently been shown to be a viable alternative to traditional post-infusion imaging methods providing good quality images of Y-laden microspheres after selective internal radiation therapy (SIRT). In the present paper, first we assessed the quantitative accuracy of Y-PET using an anthropomorphic phantom provided with lungs, liver, spine, and a cylindrical homemade lesion located into the hepatic compartment. Then, we explored the accuracy of different computational approaches on dose calculation, including (I) direct Monte Carlo radiation transport using Raydose, (II) Kernel convolution using Philips Stratos, (III) local deposition algorithm, (IV) Monte Carlo technique (MCNP) considering a uniform activity distribution, and (V) MIRD (Medical Internal Radiation Dose) analytical approach.

View Article and Find Full Text PDF

A comparison of calculations of the activity of a HO liquid scintillation source using the same experimental data set collected at the LNE-LNHB with a triple-to-double coincidence ratio (TDCR) counter was completed. A total of 17 laboratories calculated the activity and standard uncertainty of the LS source using the files with experimental data provided by the LNE-LNHB. The results as well as relevant information on the computation techniques are presented and analysed in this paper.

View Article and Find Full Text PDF

A new (18)F primary standardization carried out at ENEA-INMRI by three different absolute techniques, i.e. 4πγNaI(Tl)γ high-efficiency counting, TDCR and 4πβ(LS)-γ[NaI(Tl)] coincidence counting method, allowed the calibration of a fixed well-reentrant IG11 ionization chamber (IC), with an uncertainty lower than 1%, and to check the calibration factor of a portable well-type IC NPL-CRC model, previously calibrated.

View Article and Find Full Text PDF

A prototype of a portable liquid scintillation counting system based on the Triple-to-Double Coincidence Ratio (TDCR) technique was developed at ENEA-INMRI in the framework of the European Metrofission project. The new device equipped with the CAEN digitizers was tested for the activity measurements of pure β-emitters ((99)Tc and (63)Ni). The list-mode data recorded by the digitizers were analyzed by software implemented in the CERN ROOT environment, which allows the application of pulse shape discrimination using the new device.

View Article and Find Full Text PDF

The only commercial TDCR counter from Hidex Oy (Finland), comprising three photomultiplier tubes, was tested at the two National Metrology Institutes (NMIs) PTB and ENEA. To this end, the two NMIs purchased a Hidex 300 SL TDCR counter (METRO version) each and carried out various tests at their laboratories. In addition, the two institutions agreed to organize a bilateral comparison in order to acquire information on the reproducibility of the results obtained with the counters.

View Article and Find Full Text PDF

Current state of the art solutions based on the Triple to Double Coincidence Ratio method are generally large size, heavy-weight and not transportable systems. This is due, on one side, to large detectors and scintillation chambers and, on the other, to bulky analog electronics for data acquisition. CAEN developed a new, full digital approach to TDCR technique based on a portable, stand-alone, high-speed multichannel digitizer, on-board Digital Pulse Processing and dedicated DAQ software that emulates the well-known MAC3 analog board.

View Article and Find Full Text PDF

A new 4π (LS) TDCR system was built at ENEA-INMRI. Three photomultiplier tubes, arranged in a planar 120° geometry around a spherical optical chamber, were directly linked to a CAEN Desktop Digitizer DT5720. This module, based on the Field Programmable Gate Array (FPGA) technology for real time Digital Pulse Processing (DPP), allowed to replace all the classical TDCR electronics by only one device.

View Article and Find Full Text PDF

Background: A new 99mTc national standard has been developed at the Italian National Metrology Institute for Ionizing Radiation quantities of ENEA (ENEA-INMRI).

Methods: The stock radioactive solution was prepared at the Ospedale Pediatrico Bambino Gesù (OPBG) and standardized at the ENEA-INMRI by using the 4pigamma absolute measurement method. The new standard was used to calibrate the dose calibrator of the OPBG Nuclear Medicine Unit (NMU) and the ENEA-INMRI portable ionization chamber which was employed as the secondary standard measurement system to calibrate the dose calibrator of another Italian nuclear medicine unit.

View Article and Find Full Text PDF

A national campaign was carried out in Italy for the application of coincidence-summing correction in gamma-ray spectrometry. Twelve laboratories, belonging to the National Environmental Radioactivity Surveillance Network, took part in the campaign. They are equipped with gamma-ray spectrometry systems based on p- and n-type HPGe detectors with different relative efficiencies.

View Article and Find Full Text PDF