Publications by authors named "Marcin Gulaj"

Objective: In implantable cardiac defibrillators (ICDs), long-detection times safely reduce unnecessary and inappropriate therapies. We aimed to evaluate ICD treatment of ventricular arrhythmias in women, compared with men, also taking into account ICD detection.

Methods: The Advance III trial randomised patients implanted with an ICD for primary or secondary prevention in two arms-long and nominal ventricular arrhythmias detection times before therapy delivering (number of intervals needed to detect (NID) 30/40 and 18/24, respectively).

View Article and Find Full Text PDF

Background: Implantable cardioverter-defibrillator (ICD) therapy has been proven effective in the prevention of sudden cardiac death, but data on outcomes of ICD therapy in the young and otherwise healthy patients with long QT syndrome (LQTS) are limited.

Aim: We sought to collect data on appropriate and inappropriate ICD discharges, risk factors, and ICD-related complications.

Methods: All LQTS patients implanted with an ICD in 14 centres were investigated.

View Article and Find Full Text PDF

Objectives: This study sought to evaluate the effects of programming a long detection in single-chamber (VVI) implantable cardioverter-defibrillators (ICDs) in the multicenter prospective ADVANCE III (Avoid DeliVering TherApies for Non-sustained Arrhythmias in ICD PatiEnts III) trial.

Background: Programming strategies may reduce unnecessary ICD shocks and their adverse effects but to date have been described only for dual-chamber ICDs.

Methods: A total of 545 subjects (85% male; atrial fibrillation 25%, left ventricular ejection fraction 31%, ischemic etiology 68%, secondary prevention indications 32%) receiving a VVI ICD were randomized to long detection (30 of 40 intervals) or standard programming (18 of 24 intervals) based on device type, atrial fibrillation history, and indication.

View Article and Find Full Text PDF

Aims: A long-detection interval (LDI) (30/40 intervals) has been proved to be superior to a standard-detection interval (SDI) (18/24 intervals) in terms of reducing unnecessary implantable cardioverter defibrillator (ICD) therapies. To better evaluate the different impact of LDI and anti-tachycardia pacing (ATP) on reducing painful shocks, we assessed all treated episodes in the ADVANCE III trial.

Methods And Results: A total of 452 fast (200 ms < cycle length ≤ 320 ms) arrhythmic episodes were recorded: 284 in 138 patients in the SDI arm and 168 in 82 patients in the LDI arm (106/452 inappropriate detections).

View Article and Find Full Text PDF

Background: Three trials demonstrated recently that a long detection window reduces implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. Avoid Delivering Therapies for Nonsustained Arrhythmias in ICD Patients III (ADVANCE III) was the only trial that enrolled both primary and secondary prevention patients.

Methods And Results: Of the 1902 patients enrolled in the ADVANCE III trial, 477 received a defibrillator for secondary prevention; 248 patients were randomly assigned to a long detection setting (30 of 40 intervals) and 229 to the nominal setting (18 of 24 intervals) for ventricular arrhythmias with cycle length ≤ 320 ms.

View Article and Find Full Text PDF

Importance: Using more intervals to detect ventricular tachyarrhythmias has been associated with reducing unnecessary implantable cardioverter-defibrillator (ICD) therapies.

Objective: To determine whether using 30 of 40 intervals to detect ventricular arrhythmias (VT) (long detection) during spontaneous fast VT episodes reduces antitachycardia pacing (ATP) and shock delivery more than 18 of 24 intervals (standard detection).

Design, Setting, And Participants: Randomized, single-blind, parallel-group trial that enrolled 1902 primary and secondary prevention patients (mean [SD] age, 65 [11] years; 84% men; 75% primary prevention ICD) with ischemic and nonischemic etiology undergoing first ICD implant at 1 of 94 international centers (March 2008-December 2010).

View Article and Find Full Text PDF

Background: We studied the acute effect of pacing at the right ventricular outflow tract (RVOT), right ventricular apex (RVA) and simultaneous RVA and RVOT-dual-site right ventricular pacing (DuRV) in random order on systolic function using impedance cardiography.

Methods: Seventy-three patients (46 males), aged 52-89 years (mean 71.4 years) subjected to routine dual chamber pacemaker implantation with symptomatic chronic II or atrioventricular block, were included to the study.

View Article and Find Full Text PDF

Permanent cardiac pacing is nowadays a widespread method for the cure of conduction system diseases, improving quality of life and often saving patients' lives. In the twentieth century, scientific efforts were focused on extending battery life, improving sensitivity and reliability, minimizing the dimensions of the device and restoring atrio-ventricular synchrony and rate response. However, there is more and more evidence for the deleterious influence of chronic right ventricular pacing especially apical (RVA) pacing.

View Article and Find Full Text PDF