The ultrasonic pulse-echo technique is widely employed to measure the wall thickness reduction due to corrosion in pipelines. Ultrasonic monitoring is noninvasive and can be performed online to evaluate the structural health of pipelines. Although ultrasound is a robust technique, it presents two main difficulties arising from the temperature variation in the medium being monitored: the mechanical assembly must have high stability and the ultrasonic propagation velocity must take into account the temperature variation.
View Article and Find Full Text PDFThere are many causes for the reduction of the thickness in pipelines, tanks and other mechanical structures. Corrosion, erosion, and abrasive wear cause degradation of mechanical structures and decrease their lifespan. These can be very slow processes that are difficult to track over time.