Publications by authors named "Marcelo Giannini"

The aim of this study was to assess roughness profile and surface roughness after simulated toothbrushing cycles, as well as the degree of conversion (DC) of bulk-fill resin composites at different depths. Forty nine composite discs were made from three low-viscosity bulk-fill resins (Filtek Bulk-Fill Flowable/3M Oral Care - FBF, Beautifil-Bulk Flowable/Shofu Inc. - BBF and Surefill SDR Flow/Dentsply Caulk - SDR), three high-viscosity bulk-fill resin composites (Filtek Bulk-Fill Restorative/3M Oral Care - FBR, Beautifil-Bulk Restorative/Shofu Inc.

View Article and Find Full Text PDF

This study investigated the effects of nonthermal atmospheric pressure plasma (NAPP) application and dentin rehydration with water (REHY) on bond strength (BS) of adhesives. Three etch-and-rinse adhesives were tested: Scotchbond Multi-Purpose (SBM / water-based primer + adhesive resin), Gluma Bond Universal (GBU / single-bottle containing acetone as organic solvent) and Prime&Bond Universal (PBU / single-bottle containing propanol as organic solvent). Adhesives were applied: 1- to phosphoric acid-etched dentin (Control), 2- after NAPP application for 45 seconds to etched dentin or 3- after REHY with water (10 seconds) of plasma-treated etched dentin.

View Article and Find Full Text PDF

Objectives: To evaluate the effects of the phosphoric acid (PA) etching, self-etching technique (SE) and blasting with AlO particles (BL) on the bonding of a dental adhesive to intact (INT) or abraded (ABR) enamel.

Methods: Enamel surfaces were treated as follows: 1- ABR-PA: INT was abraded with SiC paper and etched with PA (20 s) before Clearfil Universal Bond Quick adhesive application; 2- ABR-SE: ABR was SiC and adhesive applied in SE mode; 3- INT-PA: INT was etched with PA and adhesive applied; 4- INT-SE: the adhesive (SE mode) was applied to INT; 5- INT-BL: INT was BL and the adhesive was applied (SE mode), and 6- INT-BA: INT was BL, etched with PA and adhesive applied (SE mode). The enamel surface treated was examined with scanning electron microscopy (SEM) (n = 3) and AlO particles were characterized using SEM and EDX.

View Article and Find Full Text PDF

To evaluate the effect of adhesive coats application on the enamel microtensile bond strength (µTBS) of universal adhesives, morphological etching pattern and their chemical interaction with hydroxyapatite (HA). Two universal adhesives were investigated: Scotchbond Universal (SBU, 3 M) and Prime&Bond Universal (PBU, Dentsply). The adhesives were applied in self-etching mode on bovine enamel (n = 8) in one (1L), two (2L) or three coats (3L) and light-cured as per manufacturers' instructions.

View Article and Find Full Text PDF

This study examined the effect of high irradiance and short exposure times on the depth of cure of six resin-based composites (RBCs). Bluephase PowerCure and the Valo X light-curing units (LCUs) were used to photocure bulk-fill RBCs for their recommended exposure times: Admira Fusion x-tra (AFX/20s), Aura Bulk Fill (ABF/20s), Filtek One Bulk Fill (FOB/20s), Opus Bulk Fill APS (OBF/30s), Tetric EvoCeram Bulk Fill (TEC/10s) and Tetric PowerFill (TPF/10s). In addition, all bulk-fill RBCs were tested for depth of cure with one short 3 s exposure time from the Bluephase PowerCure or the Valo X in the Xtra Power mode.

View Article and Find Full Text PDF

This study aimed to evaluate volumetric polymerization shrinkage, degree of conversion and Vickers hardness of four bulk-fill resin composites light-activated with their dedicated light curing units (LCUs). Four groups were evaluated, according to the type of composite and curing mode: Tetric EvoCeram Bulk-fill (TEBO) and Tetric EvoFlow Bulk-fill (TEBF) were light-activated with Bluephase Style 20i (20s, in high-mode), while Tetric Powerfill (TEPO) and Tetric Powerflow (TEPF) were light-activated with Bluephase PowerCure (3s). Volumetric polymerization shrinkage test (n = 6) was performed in standardized box-shaped class-I cavities of extracted third molars (4 x 4 x 4 mm).

View Article and Find Full Text PDF

Purpose: This study evaluated the effect of toothbrushing cycles on surface roughness (Ra), gloss (GU), and morphology of two zirconia finishing and polishing protocols.

Materials And Methods: An ultra-translucent zirconia disc was sectioned into rectangular plates (12 mm × 7 mm × 3 mm) and divided into two groups according to the polishing and finishing system used (diamond rubber abrasive/DRA or glazing/GLA). Bovine enamel (BEN) plates with the same dimensions were used as a Control.

View Article and Find Full Text PDF

Objective: this study evaluated dentin microtensile bond strength (µTBS) and failure modes (at 24 h and one year), bonding interface regarding hybridization, surface morphology regarding demineralization, in situ metalloproteinase (MMP) activity, and antibacterial effect of three dentin etchants compared to 35% phosphoric acid (PA).

Materials And Methods: The Adper Single Bond 2 adhesive (3 M Oral Care) was applied on moist dentin etched with PA (control) or on air-dried dentin etched with 3% aluminum nitrate + 2% oxalic acid (AN), 6.8% ferric oxalate + 10% citric acid (FO), or 10% citric acid (CA).

View Article and Find Full Text PDF

Objective: The study aims to evaluate the effect of a glass ionomer cement (GIC; Fuji 9 Gold Label, GC) with added calcium orthophosphate particles and a calcium silicate cement (CSC; Biodentine, Septodont) regarding ion release, degradation in water, mineral content, and mechanical properties of demineralized dentin samples.

Methods: GIC, GIC + 5% DCPD (dicalcium phosphate dihydrate), GIC + 15% DCPD, GIC + 5% β-TCP (tricalcium phosphate), GIC + 15% β-TCP (by mass), and CSC were evaluated for Ca/Sr/F release in water for 56 days. Cement mass loss was evaluated after 7-day immersion in water.

View Article and Find Full Text PDF
Article Synopsis
  • This study analyzed how different cementing materials used in dental procedures hold up against toothbrushing.
  • Three types of cementing materials were tested: RelyX Ultimate resin cement, RelyX Unicem 2 self-adhesive resin cement, and heated Z100 restorative composite, with various measurements taken before and after extensive toothbrushing cycles.
  • Results indicated that REXU and Z100 performed better in terms of surface roughness and volume loss compared to REU2, especially after 60,000 brush cycles, highlighting the potential differences in durability among dental materials.
View Article and Find Full Text PDF

This study aimed to evaluate surface roughness (Sa), roughness profile (Rv), and enamel wear after brushing with different whitening toothpastes and charcoal powders. Sixty (n = 10) bovine enamel blocks (6 × 6 × 3 mm) were randomly distributed into six groups according to toothpaste type: regular toothpaste (CONT), toothpaste containing 2% hydrogen peroxide (HP), toothpaste containing titanium dioxide (TiO2), toothpaste containing charcoal (COAL), toothpaste containing charcoal and TiO2 (COAL+TiO2), and activated charcoal powder (COAL_PWD). Each block was subjected to 30,000 reciprocal cycles at a 1:3 proportion slurry.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of toothbrushing on the surface roughness (Sa), roughness profile (Rv), gloss units (GU), and surface morphology of three glazed ceramics.

Materials And Methods: Specimens (n = 7) were made from the following different CAD/CAM materials and evaluated: lithium disilicate-based glass ceramic (EM); zirconia-reinforced lithium silicate glass ceramic (CE); and 6 mol% yttria partially-stabilized zirconia (IN). IPS e.

View Article and Find Full Text PDF

Purpose: To conduct a systematic review and meta-analysis of in-vitro bond strength to glass-ceramics using hydrofluoric acid (HF) at lower (<5%) and higher (>5%) concentrations ([HF]) to treat ceramic surfaces.

Methods: Systematic searches were carried out in PubMed, Scopus, LILACS, and Web of Science for articles published through July 2021, and a meta-analysis was performed to estimate the combined effect by comparing the differences between the standardized means of the bond strengths of the evaluated materials.

Results: In total, 943 articles were found, of which 17 studies were selected for qualitative analysis and 12 for quantitative analysis.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of tooth brushing and dentifrice fluoride (F-) concentration on changes in color and translucency (ΔE00 and ΔT00, respectively), surface gloss (GS), surface roughness (Sa), and microstructure of a glazed CAD/CAM ceramic.

Materials And Methods: Ceramic blocks (e.max/CAD) were sectioned into rectangular plates (14 x 12 x 1 mm), and one surface of each sample was glazed.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess how the orientation of 3D-printed provisional resins affects factors like gloss, surface roughness, and color difference.
  • Various 3D printers and resin types were used to create samples in different orientations, which were subjected to cleaning and testing after simulating wear from toothbrushing.
  • The results indicated that the orientation of the 3D-printed resins did not have a significant impact on gloss, surface roughness, maximum profile valley depth, or color difference.
View Article and Find Full Text PDF

Purpose: To evaluate the effects of etching mode (self-etch and etch-and-rinse) on acid-base resistant zone (ABRZ) formation at the resin cement/enamel interface and enamel etching pattern, as well as the effects of thermocycling (0, 5000, and 10,000 cycles) on the enamel microshear bond strength (μSBS) mediated by dual-cure resin cements (DCRC).

Materials And Methods: Two DCRC were used in 4 groups: Panavia V5 in self-etch (V5NE) and etch-and-rinse mode (V5E); and Estecem II in self-etch (ENE) and etch-and-rinse mode (EE). For ABRZ observation, the bonded interface was subjected to a demineralizing solution.

View Article and Find Full Text PDF

Objective: To analyze simplified adhesive containing pure or silanized bioglass 45S5 (with calcium) or Sr-45S5 (strontium-substituted) fillers applied on dentin and to evaluate the microtensile bond strength (µTBS), interface nanoleakage, degree of conversion of adhesive, collagen degradation and remineralization.

Methods: Ambar Universal adhesive (FGM) was doped with 10 wt% bioactive glasses to form following groups: Control (no bioglass), 45S5 (conventional bioglass 45S5), Sr-45S5 (Sr-substituted bioglass 45S5), Sil-45S5 (silanized bioglass 45S5) and Sil-Sr-45S5 (silanized bioglass Sr-45S5). Adhesives were applied after dentin acid-etching using phosphoric acid at extracted human molars.

View Article and Find Full Text PDF

The influence of different surface treatments and ageing on the shear bond strength (SBS) of computer-aided design/computer-aided manufacturing (CAD/CAM) materials is still contentious. Therefore, this study evaluated the effect of surface treatments and ageing on the SBS of resin cement to polymer-infiltrated ceramic network (PICN) and zirconia-reinforced lithium silicate (ZLS) CAD/CAM materials. Specimens of PICN (n=10) and ZLS (n=10) were submitted to four surface treatment groups: 1) 5% hydrofluoric acid etching (HF) + silanisation (SI); 2) Air abrasion (AB)+HF+SI; 3) HF + universal adhesive (UA); 4) AB+HF+SI+UA.

View Article and Find Full Text PDF

Aim: To avoid root canal recontamination and endodontic treatment failure, endodontic sealers with antibacterial activity could be an alternative. Silver nanoparticles have antibacterial activity and this study aimed to synthesize Ag@SiO nanoparticles, incorporate them into an experimental endodontic resin sealer and evaluate their influence on physicochemical and biological properties.

Methodology: Ag@SiO nanoparticles were produced using the sol-gel process, based on the Stöber method.

View Article and Find Full Text PDF

To evaluate the flexural strength (FS) and flexural modulus (FM) of a commercial 3Y-TZ0P ceramic after artificial aging and either without or with two application times of non-thermal plasma treatments (NTP). In addition, changes in crystalline phase transformation and surface nano-topography after NTP application, during different aging periods, were evaluated. Ninety 3Y-TZP bars (45x4x3 mm) were made for FS and FM testing, and assigned to nine groups (n=10): no NTP/no aging (Control); no NTP/4h aging; no NTP/30h aging; 10s NTP/no aging; 10s NTP/4h aging; 10s NTP/30h aging; 60s NTP/no aging; 60s NTP/4h aging and 60s NTP/30h aging.

View Article and Find Full Text PDF

Purpose: This study evaluated the effects of 3D-printing build orientation on accuracy, flexural modulus (FM), flexural strength (FS), and microhardness of selected, commercial 3D-printed provisional resins (3DRs).

Material And Methods: PMMA CAD/CAM provisional material (Vita Temp/Vita) served as Control. Four 3DRs (Cosmos-SLA/Yller, Cosmos-DLP/Yller, PriZma-Bioprov/Makertech, Nanolab/Wilcos) were used in three printing orientations (0°, 45°, and 90°).

View Article and Find Full Text PDF

Purpose: To evaluate the kinetics of polymerization and shrinkage stress of resin cements, as well as their bond strength to dentin after 24-h or one-year water storage.

Materials And Methods: Three conventional resin cements were evaluated: RelyX Ultimate (RUL), Panavia V5 (PNV), and Multilink N (MLN); and three self-adhesive resin cements: RelyX Unicem 2 (RUN), Panavia SA Cement Plus (PSA), and G-CEM LinkAce (GCL). Degree of conversion (DC), maximum polymerization rate (RPmax) and gel time values were obtained using Fourier-transform infrared spectroscopy (FTIR/ATR).

View Article and Find Full Text PDF

Purpose: To evaluate the effect of different luting techniques on the shear bond strength (SBS) of ultra-translucent multi-layered zirconia (UTML) after 24 hours and 1 year of water storage and to analyze the influence of primers on the wettability of the UTML MTU-6 surface.

Materials And Methods: Four commercial resin cements were evaluated: Variolink Esthetic LC (Ivoclar Vivadent); RelyX Ultimate (3M); Estecem II (Tokuyama); and Panavia V5 (Kuraray Noritake). Panavia V5 was tested with and without Panavia V5 Tooth Primer (Kuraray Noritake).

View Article and Find Full Text PDF

Purpose: To evaluate the influence of the thickness and type of computer-aided design and computer-aided manufacturing (CAD-CAM) material on the fatigue resistance and failure mode of endodontically treated teeth (ETT) restored with occlusal veneers (OV).

Materials And Methods: Seventy-five (N = 75) ETT were restored with Herculite XRV in the endodontic access. Five experimental groups (n = 15) were tested.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to assess how the thickness of high-translucency CAD/CAM materials affects the light emitted from a blue LED curing unit and its impact on the degree of conversion and polymerization rate of a resin cement.
  • - Results showed that thicker materials decreased light irradiance and affected light homogeneity negatively, although the degree of conversion of the resin cement remained largely acceptable across varying irradiance levels.
  • - Clinically, despite the reduction of light intensity through thicker CAD/CAM materials, using the light-curing unit for 30 seconds still resulted in satisfactory cement conversion.
View Article and Find Full Text PDF