Publications by authors named "Marcelo B G Funari"

Purpose: The aim of this study was to prospectively compare the detection rate of Ga-DOTATATE PET-CT with In-octreotide SPECT-CT and conventional imaging (CI) in medullary thyroid carcinoma (MTC) patients with increased calcitonin (Ctn) levels but negative CI after thyroidectomy.

Methods: Fifteen patients with raised Ctn levels and/or CI evidence of recurrence underwent Ga-DOTATATE PET-CT, In-octreotide SPECT-CT and CI. Histopathology, CI and biochemical/clinical/imaging follow-up were used as the reference standard.

View Article and Find Full Text PDF

Bulging of the inguinal region is a frequent complaint in the pediatric population and sonographic findings can be challenging for radiologists. In this review we update the sonographic findings of the most common disorders that affect the inguinal canal in neonates and children, with a focus on the processus vaginalis abnormalities such as congenital hydroceles, indirect inguinal hernias and cryptorchidism, illustrated with cases collected at a quaternary hospital during a 7-year period. We emphasize the importance of correctly classifying different types of congenital hydrocele and inguinal hernia to allow for early surgical intervention when necessary.

View Article and Find Full Text PDF

Background: The use of positron emission tomography combined with computed tomography (PET/CT) has brought about significant technological advancement in diagnostic imaging, and a number of PET/CT scanners with bismuth germanate detectors can perform imaging in both 2D and 3D acquisition modes. Nevertheless, certain image acquisition parameters and physical features of patients have to be considered when designing low-dose protocols in the 3D mode.

Purpose: The aim of this study was to compare images acquired in 2D and 3D modes and establish a low-dose protocol for use in PET/CT imaging, decreasing patient exposure to radiation without compromising results.

View Article and Find Full Text PDF

Aims: To investigate by real-time 3D echocardiography (RT3DE) and cardiac computed tomography (CCT) the analysis of left ventricle ejection fraction (LVEF) and volumes.

Methods And Results: A total of 67 patients (37 males, 55 +/- 11 years) were studied prospectively by RT3DE and by 64-slice CCT. RT3DE data: LVEF ranged from 30 to 78.

View Article and Find Full Text PDF

Background: Real-time three-dimensional echocardiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes.

Objective: To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT.

Methods: Thirty nine consecutive patients (27 men, mean age of 57+/-12 years) were studied using RT-3D-Echo and 64-slice ultrafast CT.

View Article and Find Full Text PDF