Aims: Continuous infusion thermodilution is an established technique for the assessment of absolute coronary blood flow and microvascular resistance due to its proven accuracy and reproducibility. However, for this technique to yield reliable measurements, direct and homogenous mixing of injected saline and blood is mandatory. This study aimed to assess and compare the mixing properties of two different microcatheters, namely the Rayflow® (with sideholes for infusion) and the Finecross® catheter (single end-hole for infusion), which are commonly used in the catheterization laboratory.
View Article and Find Full Text PDFBackground: Emergency Medical Services (EMS) studies have shown that prehospital risk stratification and triage decisions in patients with suspected non-ST-elevation acute coronary syndrome (NSTE-ACS) can be improved using clinical risk scores with point-of-care (POC) troponin. In current EMS studies, three different clinical risk scores are used in patients suspected of NSTE-ACS: the prehospital History, ECG, Age, Risk and Troponin (preHEART) score, History, ECG, Age, Risk and Troponin (HEART) score and Troponin-only Manchester Acute Coronary Syndromes (T-MACS). The preHEART score lacks external validation and there exists no prospective comparative analysis of the different risk scores within the prehospital setting.
View Article and Find Full Text PDFBackground: Due to aging of the population, the prevalence of aortic valve stenosis will increase drastically in upcoming years. Consequently, transcatheter aortic valve implantation (TAVI) procedures will also expand worldwide. Optimal selection of patients who benefit with improved symptoms and prognoses is key, since TAVI is not without its risks.
View Article and Find Full Text PDFBackground: Myocardial ischaemia results from insufficient coronary blood flow. Computed virtual fractional flow reserve (vFFR) allows quantification of proportional flow loss without the need for invasive pressure-wire testing. In the current study, we describe a novel, conductivity model of side branch flow, referred to as 'leak'.
View Article and Find Full Text PDFAims: Prosthetic valve endocarditis (PVE) is the most severe form of infective endocarditis associated with a high mortality rate. Whether PVE affects biological and mechanical aortic valves to the same extent remains controversial. This study aimed to compare the incidence of re-intervention because of PVE between bioprosthetic and mechanical valves.
View Article and Find Full Text PDFObjective: Prehospital risk stratification and triage are currently not performed in patients suspected of non-ST-segment elevation acute coronary syndrome (NSTE-ACS). This may lead to prolonged time to revascularisation, increased duration of hospital admission and higher healthcare costs. The preHEART score (prehospital history, ECG, age, risk factors and point-of-care troponin score) can be used by emergency medical services (EMS) personnel for prehospital risk stratification and triage decisions in patients with NSTE-ACS.
View Article and Find Full Text PDFIntroduction: Based on European guidelines, transcatheter aortic valve implementation (TAVI) could be the therapy of choice in patients with severe aortic stenosis aged ≥ 75 years. In the Netherlands, there has been a debate between healthcare providers and the National Health Care Institute regarding reimbursement for TAVI, which resulted in an indication document that defines TAVI patients who are eligible for reimbursement. This document has been effective since 1 January 2021.
View Article and Find Full Text PDFAm J Physiol Heart Circ Physiol
September 2023
When measuring hyperemic and nonhyperemic pressure ratios with traditional sensor-tipped wires, the inevitable hydrostatic pressure gradient (HPG) may influence treatment decisions. This study aimed to simulate and analyze the effect of a hydrostatic pressure gradient on different indices of functional lesion severity. A hypothetical P-P height difference and subsequent hydrostatic pressure gradient based on previous literature was applied to the pressure measurements from the CONTRAST study.
View Article and Find Full Text PDFProgression of atrial fibrillation (AF) and outcomes of ablation therapy are strongly affected by modifiable risk factors. Although previous studies show beneficial effects of modifying single risk factors, there is lack of evidence from randomized controlled trials on the effects of integrated AF lifestyle programmes. The POP trial is designed to evaluate the clinical outcomes of a dedicated nurse-led AF lifestyle outpatient clinic in patients with symptomatic AF.
View Article and Find Full Text PDFAims: Ischaemic heart disease results from insufficient coronary blood flow. Direct measurement of absolute flow (mL/min) is feasible, but has not entered routine clinical practice in most catheterization laboratories. Interventional cardiologists, therefore, rely on surrogate markers of flow.
View Article and Find Full Text PDFIntroduction: Palpitations occurring in specific body positions are often reported by patients, but the effect of body position on arrhythmia has received little research attention. We hypothesize that resting body position can exert pro-arrhythmogenic effects in various ways. For example, lateral body position is known to increase change atrial and pulmonary vein dimensions.
View Article and Find Full Text PDFSurvivors of myocardial infarction are at risk of life-threatening ventricular tachycardias (VTs) later in their lives. Current guidelines for implantable cardioverter defibrillators (ICDs) implantation to prevent VT-related sudden cardiac death is solely based on symptoms and left ventricular ejection fraction. Catheter ablation of scar-related VTs is performed following ICD therapy, reducing VTs, painful shocks, anxiety, depression and worsening heart failure.
View Article and Find Full Text PDFBackground: Determining the functional significance of each individual coronary lesion in patients with serial coronary stenoses is challenging. It has been proposed that nonhyperemic pressure ratios, such as the instantaneous wave free ratio (iFR) and the ratio of resting distal to proximal coronary pressure (Pd/Pa) are more accurate than fractional flow reserve (FFR) because autoregulation should maintain stable resting coronary flow and avoid hemodynamic interdependence (cross-talk) that occurs during hyperemia. This study aimed to measure the degree of hemodynamic interdependence of iFR, resting Pd/Pa, and FFR in a porcine model of serial coronary stenosis.
View Article and Find Full Text PDFBackground/purpose: Matching phasic pressure tracings between a fluid-filled catheter and high-fidelity pressure wire has received limited attention, although each part contributes half of the information to clinical decisions. We aimed to study the impact of a novel and automated method for improving the phasic calibration of a fluid-filled catheter by accounting for its oscillatory behavior.
Methods/materials: Retrospective analysis of drift check tracings was performed using our algorithm that corrects for mean difference (offset), temporal delays (timing), differential sensitivity of the manifold transducer and pressure wire sensor (gain), and the oscillatory behavior of the fluid-filled catheter described by its resonant frequency and damping factor (how quickly oscillations disappear after a change in pressure).
Background: The treatment of a coronary bifurcation with a single stent (the provisional stenting technique) is associated with a good outcome in most cases. In the majority of cases, after provisional stenting technique, a residual significant angiographic stenosis is associated with the absence of ischemia when fractional flow reserve (FFR) is measured. Jailing an optical pressure guidewire in the side branch (SB) could potentially reduce unnecessary SB interventions after provisional stenting technique.
View Article and Find Full Text PDFAim: Microvascular resistance reserve (MRR) as derived from continuous intracoronary thermodilution specifically quantifies microvasculature function. As originally described, the technique necessitates reinstrumentation of the artery and manual reprogramming of the infusion pump when performing resting and hyperemic measurements. To simplify and to render this procedure operator-independent, we developed a fully automated method.
View Article and Find Full Text PDFQuantification of coronary blood flow is used to evaluate coronary artery disease, but our understanding of flow through branched systems is poor. Murray's law defines coronary morphometric scaling, the relationship between flow (Q) and vessel diameter (D) and is the basis for minimum lumen area targets when intervening on bifurcation lesions. Murray's original law (Q D) dictates that the exponent (P) is 3.
View Article and Find Full Text PDFObjectives: It is unknown whether computed tomographic coronary angiography (CTCA) can be used to perform ultraselective invasive coronary angiography (ICA) by only visualizing the abnormal coronary artery on CTCA and defer visualization of the normal contralateral coronary artery. This study assessed the accuracy of CTCA in patients with coronary artery disease (CAD) on CTCA limited to either the left (LCA) or right coronary artery (RCA) in predicting a contralateral coronary artery without abnormalities on CTCA determined to be normal by ICA.
Methods: This retrospective analysis included patients with CAD limited to the LCA or RCA on CTCA.
The timely revascularization of an occluded coronary artery is the cornerstone of treatment in patients with ST-elevation myocardial infarction (STEMI). As essential as this treatment is, it can also cause additional damage to cardiomyocytes that were still viable before reperfusion, increasing infarct size. This has been termed "myocardial reperfusion injury".
View Article and Find Full Text PDFTher Hypothermia Temp Manag
June 2022
In acute myocardial infarction (AMI), myocardial reperfusion injury may undo part of the recovery after revascularization of the occluded coronary artery. Selective intracoronary hypothermia is a novel method aimed at reducing myocardial reperfusion injury, but its presumed protective effects in AMI still await further elucidation. This proof-of-concept study assesses the potential protective effects of selective intracoronary hypothermia in an , isolated beating heart model of AMI.
View Article and Find Full Text PDF