Four-dimensional scanning transmission electron microscopy (4D-STEM) offers an attractive approach to simultaneously obtain precise structural determinations and capture details of local electric fields and charge densities. However, accurately extracting quantitative data at the atomic scale poses challenges, primarily due to probe propagation and size-related effects, which may even lead to misinterpretations of qualitative effects. In this study, we present a comprehensive analysis of electric fields and charge densities in both pristine and defective h-BN flakes.
View Article and Find Full Text PDFDirect electron detection is currently revolutionizing many fields of electron microscopy due to its lower noise, its reduced point-spread function, and its increased quantum efficiency. More specifically to this work, Timepix3 is a hybrid-pixel direct electron detector capable of outputting temporal information of individual hits in its pixel array. Its architecture results in a data-driven detector, also called event-based, in which individual hits trigger the data off the chip for readout as fast as possible.
View Article and Find Full Text PDFThe synergy between free electrons and light has recently been leveraged to reach an impressive degree of simultaneous spatial and spectral resolution, enabling applications in microscopy and quantum optics. However, the required combination of electron optics and light injection into the spectrally narrow modes of arbitrary specimens remains a challenge. Here, we demonstrate microelectronvolt spectral resolution with a sub-nanometer probe of photonic modes with quality factors as high as 10.
View Article and Find Full Text PDFFollowing optical excitations' life span from creation to decay into photons is crucial in understanding materials photophysics. Macroscopically, this is studied using optical techniques, such as photoluminescence excitation spectroscopy. However, excitation and emission pathways can vary at nanometer scales, preventing direct access, as no characterization technique has the relevant spatial, spectral, and time resolution.
View Article and Find Full Text PDFUltramicroscopy
September 2022
The acquisition of a hyperspectral image is nowadays a standard technique used in the scanning transmission electron microscope. It relates the spatial position of the electron probe to the spectral data associated with it. In the case of electron energy loss spectroscopy (EELS), frame-based hyperspectral acquisition is much slower than the achievable rastering time of the scan unit (SU), which sometimes leads to undesirable effects in the sample, such as electron irradiation damage, that goes unperceived during frame acquisition.
View Article and Find Full Text PDFWhispering-gallery mode resonators host multiple trapped narrow-band circulating optical resonances that find applications in quantum electrodynamics, optomechanics, and sensing. However, the spherical symmetry and low field leakage of dielectric microspheres make it difficult to probe their high-quality optical modes using far-field radiation. Even so, local field enhancement from metallic nanoparticles (MNPs) coupled to the resonators can interface the optical far field and the bounded cavity modes.
View Article and Find Full Text PDFThis paper discusses the reconstruction of partially sampled spectrum-images to accelerate the acquisition in scanning transmission electron microscopy (STEM). The problem of image reconstruction has been widely considered in the literature for many imaging modalities, but only a few attempts handled 3D data such as spectral images acquired by STEM electron energy loss spectroscopy (EELS). Besides, among the methods proposed in the microscopy literature, some are fast but inaccurate while others provide accurate reconstruction but at the price of a high computation burden.
View Article and Find Full Text PDFAtomic vibrations and phonons are an excellent source of information on nanomaterials that we can access through a variety of methods including Raman scattering, infrared spectroscopy, and electron energy-loss spectroscopy (EELS). In the presence of a plasmon local field, vibrations are strongly modified and, in particular, their dipolar strengths are highly enhanced, thus rendering Raman scattering and infrared spectroscopy extremely sensitive techniques. Here, we experimentally demonstrate that the interaction between a relativistic electron and vibrational modes in nanostructures is fundamentally modified in the presence of plasmons.
View Article and Find Full Text PDFThe evolution of the scanning modules for scanning transmission electron microscopes (STEM) allows now to generate arbitrary scan pathways, an approach currently explored to improve acquisition speed and to reduce electron dose effects. In this work, we present the implementation of a random scan operating mode in STEM achieved at the hardware level via a custom scan control module. A pre-defined pattern with fully shuffled raster order is used to sample the entire region of interest.
View Article and Find Full Text PDFPlasmon modes of the exact same individual gold nanoprisms are investigated through combined nanometer-resolved electron energy-loss spectroscopy (EELS) and cathodoluminescence (CL) measurements. We show that CL only probes the radiative modes, in contrast to EELS, which additionally reveals dark modes. The combination of both techniques on the same particles thus provides complementary information and also demonstrates that although the radiative modes give rise to very similar spatial distributions when probed by EELS or CL, their resonant energies appear to be different.
View Article and Find Full Text PDFSpatially resolved electron energy loss spectroscopy (SR-EELS) using scanning transmission electron microscope (STEM) allows the identification and determination of the spatial distribution of the components/elements of immuno-functionalized core-shell superparamagnetic magnetite nanoparticles. Here, we report that SR-EELS measurements allow the direct identification and study of the biological moieties (protein G and anti-HRP antibody) in complex bionanocarriers of relevance for biomedical applications. Our findings show that the biomacromolecules are located on specific areas on the nanoparticles' surface.
View Article and Find Full Text PDFWe report the spectral imaging in the UV to visible range with nanometer scale resolution of closely packed GaN/AlN quantum disks in individual nanowires using an improved custom-made cathodoluminescence system. We demonstrate the possibility to measure full spectral features of individual quantum emitters as small as 1 nm and separated from each other by only a few nanometers and the ability to correlate their optical properties to their size, measured with atomic resolution. The direct correlation between the quantum disk size and emission wavelength provides evidence of the quantum confined Stark effect leading to an emission below the bulk GaN band gap for disks thicker than 2.
View Article and Find Full Text PDFThis work aims to improve the quality of scintigraphy. It evaluates the use of a large-hole collimator, the Computer Aided Collimation Gamma Camera Project (CACAO), in SPECT. Acquisition data from the same object were simulated for CACAO and for a conventional collimator.
View Article and Find Full Text PDF