Publications by authors named "Marcel Reese"

We describe the design and construction of a modular, triple-resonance, fully balanced, DNP-MAS probe based on transmission line technology and its integration into a 500 MHz/330 GHz DNP-NMR spectrometer. A novel quantitative probe design and characterization strategy is developed and employed to achieve optimal sensitivity, RF homogeneity and excellent isolation between channels. The resulting three channel HCN probe has a modular design with each individual, swappable module being equipped with connectorized, transmission line ports.

View Article and Find Full Text PDF

Continuous-wave (CW) dynamic nuclear polarization (DNP) is now established as a method of choice to enhance the sensitivity in a variety of NMR experiments. Nevertheless, there remains a need for the development of more efficient methods to transfer polarization from electrons to nuclei. Of particular interest are pulsed DNP methods because they enable a rapid and efficient polarization transfer that, in contrast with CW DNP methods, is not attenuated at high magnetic fields.

View Article and Find Full Text PDF

We report a magic angle spinning (MAS) NMR structure of the drug-resistant S31N mutation of M218-60 from Influenza A. The protein was dispersed in diphytanoyl-sn-glycero-3-phosphocholine lipid bilayers, and the spectra and an extensive set of constraints indicate that M218-60 consists of a dimer of dimers. In particular, ∼280 structural constraints were obtained using dipole recoupling experiments that yielded well-resolved (13)C-(15)N, (13)C-(13)C, and (1)H-(15)N 2D, 3D, and 4D MAS spectra, all of which show cross-peak doubling.

View Article and Find Full Text PDF

A DNP set-up is described where a liquid sample is hyperpolarized by the electron-nucleus Overhauser effect in a field of 0.34 T and transferred to a field of 14.09 T for NMR detection.

View Article and Find Full Text PDF

Dynamic nuclear polarization is emerging as a potential tool to increase the sensitivity of NMR aiming at the detection of macromolecules in liquid solution. One possibility for such an experimental design is to perform the polarization step between electrons and nuclei at low magnetic fields and then transfer the sample to a higher field for NMR detection. In this case, an independent optimization of the polarizer and detection set ups is required.

View Article and Find Full Text PDF

Dynamic nuclear polarization (DNP) permits increasing the NMR signal of nuclei by pumping the electronic spin transitions of paramagnetic centers nearby. This method is emerging as a powerful tool to increase the inherent sensitivity of NMR in structural biology aiming at detection of macromolecules. In aqueous solution, additional technical issues associated with the penetration of microwaves in water and heating effects aggravate the performance of the experiment.

View Article and Find Full Text PDF