Contrast-enhanced endoscopic ultrasound (CH-EUS) can overcome the limitations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of these tumours. Despite the initial enthusiasm that oriented needle sampling under CH-EUS guidance could provide better diagnostic yield in pancreatic solid lesions, further studies did not confirm the supplementary values in cases of tissue acquisition guided by CH-EUS. This review details the knowledge based on the available data on contrast-guided procedures.
View Article and Find Full Text PDFEndoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) or fine-needle aspiration (EUS-FNA) from focal liver lesions are indicated in selected cases, but there has been no previous comparison of needle types of the same size. The aim of our study was to compare the histologic diagnostic accuracy and adequacy of cores obtained with EUS-FNB needles in contrast to those obtained with FNA needles in focal liver lesions. This prospective one-center study included patients with left lobe hepatic focal lesions with contraindications for percutaneous liver biopsy or need for EUS for concomitant lesions.
View Article and Find Full Text PDFEndoscopic ultrasound fine needle aspiration (EUS-FNA) cytology from an intracystic fluid is useful in the differentiation of pancreatic cysts, with low sensitivity, which increases when the solid component is targeted. The clinical utility of contrast-enhanced guided EUS-FNA (CH-EUS-FNA) in the solid component is not known. We aimed to assess the diagnostic value of CH-EUS-FNA in enhanced mural nodules and discrimination between different cysts using contrast-enhanced endoscopic ultrasound (CH-EUS).
View Article and Find Full Text PDFElastography endoscopic ultrasound (E-EUS) has been proved to be a valuable supplement to endoscopic ultrasound fine-needle aspiration (EUS-FNA) in differentiating solid pancreatic lesions, but the improvement of EUS-FNA guided during E-EUS has not been proven. Our study aimed to evaluate whether E-EUS fine-needle aspiration (E-EUS-FNA) was superior to B-mode EUS-FNA for the diagnosis of solid pancreatic masses and whether the diagnostic rate was affected by specific factors. Our prospective study was conducted between 2019-2020 by recruiting patients with solid pancreatic masses.
View Article and Find Full Text PDFBackground And Aims: The fully-covered, lumen apposing metal stents are designed for one step placement, facilitating the direct endoscopic necrosectomy into the walled-off pancreatic necrosis. However, the prediction of the number of necrosectomy sessions in these patients is not known. This study evaluated the association between the proportion of solid necrotic material inside walled-off necrosis, as assessed during the endosonography placement of a lumen apposing metal stent, and the number of necrosectomies subsequently required.
View Article and Find Full Text PDFBackground: Endoscopic ultrasonography-guided fine-needle aspiration (EUS-FNA) is important for the differential diagnosis of solid pancreatic lesions. Sample adequacy is related to the number of needle passes, and European guidelines recommend three to four needle passes with a standard EUS-FNA needle. We aimed to evaluate the optimal number of passes with standard EUS-FNA needles in solid pancreatic lesions.
View Article and Find Full Text PDFUnlabelled: We present an unusual case of an intra-abdominal collection which evidenced a rare etiology and raises diagnostic particularities.
Background: Fish bones ingestion is frequent, but seldom followed by complications. Those are often reported at specific sites.
Background: Contrast-enhanced harmonic endoscopic ultrasound (CH-EUS) can visualize necrotic areas and vessels inside lesions. CH-EUS findings combined with EUS-guided fine-needle aspiration (EUS-FNA) improves diagnosis in pancreatic solid masses. CH-EUS can also guide EUS-FNA (CH-EUS-FNA), potentially improving the diagnostic rate of EUS-FNA, but such superiority has not been proved in prospective studies.
View Article and Find Full Text PDFThis case reports a iatrogenic gastric fistula due to external draining successfully closed by using an over- the-scope clip. A 50-year old patient with a history of acute pancreatitis, segmental portal hypertension and splenectomy for splenic rupture, with long-term external drainage for a low volume pancreatic fistula, was referred to our hospital. The patient noticed the occurrence of a sudden increase of the drain flow and the immediate drainage of ingested liquid, with no fever or pain.
View Article and Find Full Text PDFBackground And Aim: Endoscopic ultrasonography (EUS) and EUS-guided fine-needle aspiration (EUS-FNA) are considered good tools for the diagnosis of pancreatic cancer and for obtaining material for cytology or histology. The accuracy of EUS-FNA can rise to 85-95%, but it is lower in cases with a chronic pancreatitis background or with previous biliary stenting. We aimed to establish the diagnostic yield of the visible length of the core biopsy samples in pancreatic cancer by using one single type of standard 22G needle and to evaluate the factors which can influence the results.
View Article and Find Full Text PDF