Publications by authors named "Marc Nuwer"

Background And Objectives: High costs associated with after-hour electroencephalography (EEG) constitute a barrier for financially constrained hospitals to provide this neurodiagnostic procedure outside regular working hours. Our study aims to deepen our understanding of the cost elements involved in delivering EEG services during after-hours.

Methods: We accessed publicly available data sets and created a cost model depending on 3 most commonly seen staffing scenarios: (1) technologist on-site, (2) technologist on-call from home, and (3) a hybrid of the two.

View Article and Find Full Text PDF

The Guidelines for Qualifications of Neurodiagnostic Personnel (QNP) document has been created through the collaboration of the American Clinical Neurophysiology Society (ACNS), the American Society of Neurophysiological Monitoring (ASNM), the American Association of Neuromuscular & Electrodiagnostic Medicine (AANEM), and ASET The Neurodiagnostic Society (ASET). The quality of patient care is optimized when neurophysiological procedures are performed and interpreted by appropriately trained and qualified practitioners at every level. These societies recognize that neurodiagnostics is a large field with practitioners who have entered the field through a variety of training paths.

View Article and Find Full Text PDF

The Guidelines for Qualifications of Neurodiagnostic Personnel (QNP) document has been created through the collaboration of the American Clinical Neurophysiology Society (ACNS), the American Society of Neurophysiological Monitoring (ASNM), the American Association of Neuromuscular & Electrodiagnostic Medicine (AANEM), and ASET - The Neurodiagnostic Society (ASET). The quality of patient care is optimized when neurophysiological procedures are performed and interpreted by appropriately trained and qualified practitioners at every level. These Societies recognize that Neurodiagnostics is a large field with practitioners who have entered the field through a variety of training paths.

View Article and Find Full Text PDF

The Guidelines for Qualifications of Neurodiagnostic Personnel (QNP) document has been created through the collaboration of the American Clinical Neurophysiology Society (ACNS), the American Society of Neurophysiological Monitoring (ASNM), the American Association of Neuromuscular & Electrodiagnostic Medicine (AANEM), and ASET-The Neurodiagnostic Society (ASET). The quality of patient care is optimized when neurophysiological procedures are performed and interpreted by appropriately trained and qualified practitioners at every level. These societies recognize that neurodiagnostics is a large field with practitioners who have entered the field through a variety of training paths.

View Article and Find Full Text PDF

Intraoperative neuromonitoring (IONM) is used widely to reduce neurologic adverse postoperative outcomes. A variety of techniques are used. Initial techniques were used as far back as the 1930s, and the variety of methods expanded greatly since the 1980s.

View Article and Find Full Text PDF

Surgery to correct a spinal deformity incurs a risk of injury to the spinal cord and roots. Injuries include postoperative paraplegia. Surgery for cervical myelopathy also incurs risk for postoperative motor deficits, as well as nerve injury most commonly at the C5 root.

View Article and Find Full Text PDF

Electroencephalography (EEG) and electrocorticography (ECoG) are two important neurophysiologic techniques used in the operating room for monitoring and mapping electrical brain activity. In this chapter, we detail their principle, recording methodology, and address specifics of their interpretation in the intraoperative setting (e.g.

View Article and Find Full Text PDF

Intraoperative neuromonitoring (IONM) complements modern presurgical investigations by providing information about the epileptic focus as well as real-time identification of critical functional tissue and assessment of ongoing neural integrity during resective epilepsy surgery. This chapter summarizes current IONM methods for mapping the epileptic focus and for mapping and monitoring functionally important structures with direct brain stimulation and evoked potentials. These techniques include electrocorticography, computerized high-frequency oscillation mapping, single-pulse electric stimulation, cortical and subcortical motor evoked potentials, somatosensory evoked potentials, visual evoked potentials, and cortico-cortical evoked potentials.

View Article and Find Full Text PDF

Background And Objectives: We set out to improve outpatient neurology access while reducing patient volume in the emergency department (ED) for nonemergent neurologic complaints.

Methods: We created a rapid access model, University of California Los Angeles (UCLA) Fast Neuro, for patients referred from affiliated EDs to outpatient neurology, enabling appointments within 1 week of referral. Rapid access appointments were also available to established neurology patients with urgent concerns.

View Article and Find Full Text PDF

Opioid overdose suppresses brainstem respiratory circuits, causes apnoea and may result in death. Epidural electrical stimulation (EES) at the cervical spinal cord facilitated motor activity in rodents and humans, and we hypothesized that EES of the cervical spinal cord could antagonize opioid-induced respiratory depression in humans. Eighteen patients requiring surgical access to the dorsal surface of the spinal cord between C2 and C7 received EES or sham stimulation for up to 90 s at 5 or 30 Hz during complete (OFF-State) or partial suppression (ON-State) of respiration induced by remifentanil.

View Article and Find Full Text PDF

Despite many decades of research, controversy regarding the utility of quantitative EEG (qEEG) for the accurate diagnosis of mild traumatic brain injury (mTBI) remains. This guideline is meant to assist clinicians by providing an expert review of the clinical usefulness of qEEG techniques for the diagnosis of mTBI. This guideline addresses the following primary aim: For patients with or without posttraumatic symptoms (abnormal cognition or behavior), does qEEG either at the time of injury or remote from the injury, as compared with current clinical diagnostic criteria, accurately identify those patients with mTBI (i.

View Article and Find Full Text PDF

Purpose: To survey US Clinical Neurophysiology (CNP) fellowship program directors on the nature of CNP and related training programs, current recruitment cycle, and views for a standardized process.

Methods: A 23-question electronic survey was sent to all 93 US Accreditation Council for Graduate Medical Education-accredited CNP fellowship program directors from December 2020 to January 2021.

Results: The response rate was 60%.

View Article and Find Full Text PDF
Spinal cord monitoring.

Handb Clin Neurol

December 2019

Spinal cord surgery carries the risk of spinal cord or nerve root injury. Neurophysiologic monitoring decreases risk of injury by continuous assessment of spinal cord and nerve root function throughout surgery. Techniques include somatosensory evoked potentials (SEPs), transcranial electrical motor evoked potentials (MEPs), and electromyography (EMG).

View Article and Find Full Text PDF

Coding specifies the work performed when providing patient care. Critical care services mostly use code 99291, and other codes specify additional time and procedures. Current Procedural Terminology defines critically ill as "a high probability of imminent or life-threatening deterioration in the patient's condition," a condition necessary for use of the critical care code.

View Article and Find Full Text PDF