Background: To assess the integrity of the developing nervous system, the Prechtl general movement assessment (GMA) is recognized for its clinical value in diagnosing neurological impairments in early infancy. GMA has been increasingly augmented through machine learning approaches intending to scale-up its application, circumvent costs in the training of human assessors and further standardize classification of spontaneous motor patterns. Available deep learning tools, all of which are based on single sensor modalities, are however still considerably inferior to that of well-trained human assessors.
View Article and Find Full Text PDFCommun Med (Lond)
August 2023
Background: Aiming at objective early detection of neuromotor disorders such as cerebral palsy, we propose an innovative non-intrusive approach using a pressure sensing device to classify infant general movements. Here we differentiate typical general movement patterns of the "fidgety period" (fidgety movements) vs. the "pre-fidgety period" (writhing movements).
View Article and Find Full Text PDFBackground: The clinical and scientific value of Prechtl general movement assessment (GMA) has been increasingly recognised, which has extended beyond the detection of cerebral palsy throughout the years. With advancing computer science, a surging interest in developing automated GMA emerges.
Aims: In this scoping review, we focused on video-based approaches, since it remains authentic to the non-intrusive principle of the classic GMA.
Background: Skin diseases can develop upon disadvantageous microclimate in relation to skin contact with textiles of supporting devices. Increased temperature, moisture, mechanical fracture, pressure, and inflammatory processes often occur mutually and enhance each other in their adverse effects. Therefore, the early prevention of skin irritations by improvement of microclimatic properties of skin in contact with supporting devices is important.
View Article and Find Full Text PDFBiomed Tech (Berl)
February 2019
A crossover design study with a small group of subjects was used to evaluate the performance of three microprocessor-controlled exoprosthetic knee joints (MPKs): C-Leg 4, Plié 3 and Rheo Knee 3. Given that the mechanical designs and control algorithms of the joints determine the user outcome, the influence of these inherent differences on the functional characteristics was investigated in this study. The knee joints were evaluated during level-ground walking at different velocities in a motion analysis laboratory.
View Article and Find Full Text PDFPurpose: Bipolar radio-frequency-induced thermofusion (BiRTh) of intestinal tissue might replace conventional stapling devices which are associated with technical and functional complications. Previous results of our study group confirmed the feasibility to fuse intestinal tissue using BiRTh-induced thermofusion ex vivo. The aim of this study was now to evaluate the efficacy of fusing intestinal tissue in vivo by BiRTh-induced thermofusion.
View Article and Find Full Text PDFHigh strain magnitude and low strain frequency are important stimuli for tendon adaptation. Increasing the rate and duration of the applied strain may enhance the adaptive responses. Therefore, our purpose was to investigate the effect of strain rate and duration on Achilles tendon adaptation.
View Article and Find Full Text PDFIn this comparative study, three transfemoral amputee subjects were fitted with four different microprocessor-controlled exoprosthetic knee joints (MPK): C-Leg, Orion, Plié2.0, and Rel-K. In a motion analysis laboratory, objective gait measures were acquired during level walking at different velocities.
View Article and Find Full Text PDFPurpose: In recent years, vessel sealing has become a well-established method in surgical practice for sealing and transecting vessels. Since this technology depends on the fusion of collagen fibers abundantly present in the intestinal wall, it should also be possible to create intestinal anastomoses by thermofusion. Bipolar radiofrequency-induced thermofusion of intestinal tissue may replace traditionally used staples or sutures in the future.
View Article and Find Full Text PDFPurpose: Vessel sealing has been well-established in surgical practice in recent years. Bipolar radiofrequency-induced thermofusion (BIRTH) of intestinal tissue might replace traditionally used staples or sutures in the near future. In this experimental study, the influence of compressive pressure, fusion temperature, and duration of heating on the quality of intestinal anastomosis was investigated to obtain the relevant major parameters for the in vivo use of this system.
View Article and Find Full Text PDFGMS Krankenhhyg Interdiszip
September 2008
GMS Krankenhhyg Interdiszip
September 2008
Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device.
View Article and Find Full Text PDF