Publications by authors named "Marc Brouwer"

Article Synopsis
  • Inappropriate therapy (IAT) is a significant issue associated with implantable cardiac defibrillator (ICD) therapy, particularly highlighted in early subcutaneous ICD (S-ICD) studies which showed high rates of inappropriate shocks (IAS).
  • The PRAETORIAN trial, an international study with 849 patients, found no major differences in IAT and IAS rates between S-ICD and transvenous ICD (TV-ICD) groups, as both groups had similar cumulative incidences.
  • Key predictors for IAT varied between the two groups, with TV-ICD patients experiencing IAT mainly from supraventricular tachycardias, while S-ICD patients faced issues from cardiac oversensing
View Article and Find Full Text PDF
Article Synopsis
  • The S-ICD was created to eliminate lead-related issues found in the TV-ICD, as it is an external device that sits under the skin rather than using leads inside the body.
  • This analysis comes from the PRAETORIAN trial, where patients were randomly assigned to either S-ICD or TV-ICD and assessed for quality of life through various questionnaires at different stages.
  • Results showed no significant differences in physical and mental well-being between the groups, but patients who experienced a shock recently reported lower social functioning and emotional health compared to those who did not.
View Article and Find Full Text PDF

Background: Unwitnessed out-of-hospital cardiac arrest is associated with low survival chances because of the delayed activation of the emergency medical system in most cases. Automated cardiac arrest detection and alarming using biosensor technology would offer a potential solution to provide early help. We developed and validated an algorithm for automated circulatory arrest detection using wrist-derived photoplethysmography from patients with induced circulatory arrests.

View Article and Find Full Text PDF
Article Synopsis
  • The subcutaneous implantable cardioverter-defibrillator (S-ICD) was designed to reduce complications linked to traditional transvenous ICD (TV-ICD) therapy, such as lead issues and infections.
  • The PRAETORIAN trial, which included 849 patients, found that while both devices had complications, the S-ICD group experienced fewer lead-related issues and systemic infections compared to the TV-ICD group.
  • The trial results indicate that complications from the TV-ICD were more severe, often requiring invasive procedures, highlighting the S-ICD as a safer alternative for patients needing ICD therapy.
View Article and Find Full Text PDF

Background: Ion channel inhibition may offer protection against coronavirus disease 2019 (COVID-19). Inflammation and reduced platelet count occur during COVID-19 but precise quantification of risk thresholds is unclear. The Recov ery-SIRIO study aimed to assess clinical effects of amiodarone and verapamil and to relate patient phenotypes to outcomes.

View Article and Find Full Text PDF

Importance: Increased bystander cardiopulmonary resuscitation (CPR) is essential to improve survival after cardiac arrest. Although most studies focus on technical CPR skills, the randomized Lowlands Saves Lives trial prespecified a follow-up survey on other important aspects that affect the widespread performance of CPR.

Objective: To investigate bystander willingness to perform CPR on a stranger, theoretical knowledge retention, and dissemination of CPR awareness 6 months after undergoing short face-to-face and virtual reality (VR) CPR trainings.

View Article and Find Full Text PDF

Introduction: On-scene detection of acute coronary occlusion (ACO) during ongoing ventricular fibrillation (VF) may facilitate patient-tailored triage and treatment during cardiac arrest. Experimental studies have demonstrated the diagnostic potential of the amplitude spectrum area (AMSA) of the VF-waveform to detect myocardial infarction (MI). In follow-up, we performed this clinical pilot study on VF-waveform based discriminative models to diagnose acute MI due to ACO in real-world VF-patients.

View Article and Find Full Text PDF
Article Synopsis
  • The PRAETORIAN trial compared the effectiveness of subcutaneous implantable cardioverter defibrillators (S-ICD) and transvenous implantable cardioverter defibrillators (TV-ICD), showing that S-ICD was noninferior in terms of inappropriate shocks and complications.
  • A secondary analysis examined whether antitachycardia pacing in TV-ICD reduced appropriate shocks, particularly for patients with serious ventricular arrhythmias.
  • Results indicated that S-ICD patients received appropriate therapy slightly more often than TV-ICD patients, but overall shock rates were comparable, with S-ICD demonstrating high shock efficacy.
View Article and Find Full Text PDF

Aims: At present, there are no guideline recommendations for minimally interrupted use of non-vitamin K antagonist oral anticoagulants (mi-NOAC) during catheter ablation (CA) for atrial fibrillation (AF). Current evidence is predominantly based on observational studies, with continuous use of vitamin K antagonist in the control arm. This quantitative summary reflects the first high-level evidence on contemporary regimens, with continuous NOAC use (c-NOAC) as the current gold standard.

View Article and Find Full Text PDF

Aim: In cardiac arrest, ventricular fibrillation (VF) waveform analysis has identified the amplitude spectrum area (AMSA) as a key predictor of defibrillation success and favorable neurologic survival. New resuscitation protocols are under investigation, where prompt defibrillation is restricted to cases with a high AMSA. Appreciating the variability of in-field pad placement, we aimed to assess the impact of recording direction on AMSA-values, and the inherent defibrillation advice.

View Article and Find Full Text PDF

Since the first report of an association between cardiac troponin (cTn) and adverse outcome in hypertrophic cardiomyopathy (HD), there is a paucity in confirmative data. We performed a prospective, prespecified 5-year follow-up cohort study of 135 HC patients who participated in a national multicenter project and underwent clinical evaluation, MRI (cine, LGE and T2-weighted imaging) and biomarker assessment (high-sensitivity cTnT (hs-cTnT), N-terminal pro-B-type natriuretic peptide, soluble tumorgenicity suppressor-2, Galectin-3, Growth differentiation factor-15, C-terminal Propeptide of Type I Collagen (CICP)). An elevated hs-cTnT concentration was defined as ≥14ng/L.

View Article and Find Full Text PDF

Aims: The value of elective coronary revascularisation plus medical therapy over medical therapy alone in managing stable patients with coronary artery disease is debated. We reviewed all trials comparing the two strategies in this population.

Methods And Results: From inception through November 2020, MEDLINE, EMBASE, Google Scholar, and other databases were searched for randomised trials comparing revascularisation against medical therapy alone in clinically stable coronary artery disease patients.

View Article and Find Full Text PDF

Background And Aims: The impact of advanced age on the optimal duration of dual antiplatelet therapy (DAPT) in patients with acute coronary syndrome (ACS) undergoing percutaneous coronary revascularization (PCI) is still greatly debated. Therefore, the aim of the present sub-analysis of the REDUCE trial was to assess the impact of age on the comparison between a short 3 months vs standard 12 months DAPT in ACS patients treated with the COMBO Dual Stent Therapy.

Methods: The REDUCE trial is a prospective, multicenter, investigator-initiated study that randomized ACS patients undergoing PCI with the COMBO drug eluting stent to either 3 or 12 months of DAPT.

View Article and Find Full Text PDF

Background: Catheter ablation for persistent atrial fibrillation (persAF) is associated with less favorable outcomes than for paroxysmal AF. To improve success rates, left atrial (LA) substrate modification is frequently performed in addition to pulmonary vein isolation (PVI). The purpose of the study was to compare 4 different ablation approaches using radiofrequency catheter ablation (RFCA) or cryoballoon ablation (CB-A) for persAF and to evaluate the respective outcomes on a midterm follow-up of 12 months.

View Article and Find Full Text PDF

Aims: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation.

Methods And Results: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively.

View Article and Find Full Text PDF

Background Dissemination of cardiopulmonary resuscitation (CPR) skills is essential for cardiac arrest survival. Virtual reality (VR)-training methods are low cost and easily available, but to meet depth requirements adaptations are required, as confirmed in a recent randomized study on currently prevailing CPR quality criteria. Recently, the promising clinical performance of new CPR quality criteria was demonstrated, based on the optimal combination of compression depth and rate.

View Article and Find Full Text PDF

Background: Troponin composition characterization has been implicated as a next step to differentiate among non-ST elevation myocardial infarction (NSTEMI) patients and improve distinction from other conditions with troponin release. We therefore studied coronary and peripheral troponin compositions in relation to clinical variables of NSTEMI patients.

Methods: Samples were obtained from the great cardiac vein (GCV), coronary sinus (CS), and peripheral circulation of 45 patients with NSTEMI.

View Article and Find Full Text PDF

Patients who undergo transcatheter aortic valve replacement often are frail and elderly. Delirium is a frequently observed complication, associated with impaired recovery, prolonged hospital stay, and mortality. In different hospital settings, interventions that reduced the incidence of delirium resulted in improved clinical outcome and reduced costs.

View Article and Find Full Text PDF

Background In cardiac arrest, computerized analysis of the ventricular fibrillation (VF) waveform provides prognostic information, while its diagnostic potential is subject of study. Animal studies suggest that VF morphology is affected by prior myocardial infarction (MI), and even more by acute MI. This experimental in-human study reports on the discriminative value of VF waveform analysis to identify a prior MI.

View Article and Find Full Text PDF

Background: Approximately 15% of saphenous vein grafts (SVGs) occlude during the first year after coronary artery bypass graft surgery (CABG) despite aspirin use. The POPular CABG trial (The Effect of Ticagrelor on Saphenous Vein Graft Patency in Patients Undergoing Coronary Artery Bypass Grafting Surgery) investigated whether ticagrelor added to standard aspirin improves SVG patency at 1 year after CABG.

Methods: In this investigator-initiated, randomized, double-blind, placebo-controlled, multicenter trial, patients with ≥1 SVGs were randomly assigned (1:1) after CABG to ticagrelor or placebo added to standard aspirin (80 mg or 100 mg).

View Article and Find Full Text PDF

Introduction: Anticoagulation therapy is pivotal in the management of stroke prevention in atrial fibrillation (AF). Prospective registries, containing longitudinal data are lacking with detailed information on anticoagulant therapy, treatment adherence and AF-related adverse events in practice-based patient cohorts, in particular for non-vitamin K oral anticoagulants (NOAC). With the creation of DUTCH-AF, a nationwide longitudinal AF registry, we aim to provide clinical data and answer questions on the (anticoagulant) management over time and of the clinical course of patients with newly diagnosed AF in routine clinical care.

View Article and Find Full Text PDF

Background: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies.

Methods: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD.

View Article and Find Full Text PDF