Statement Of Problem: Characterizing interim restorations promotes esthetics. However, studies on the effects of characterization materials on the surface roughness and gloss of interim materials after toothbrushing are lacking.
Purpose: The purpose of this in vitro study was to evaluate the surface roughness and gloss of 5 different interim materials with different surface treatments after 1 year of simulated toothbrushing.
Background: Digitally fabricated dentures may require relining due to continual alveolar ridge resorption. However, studies evaluating the tensile bond strength (TBS) of digitally fabricated dentures bonded to denture liners are lacking. This study aimed to evaluate the TBS of autopolymerized, heat-polymerized, milled, and 3D printed denture base materials bonded to 2 acrylic-based and 2 silicone-based denture liners, both before and after thermocycling.
View Article and Find Full Text PDFObjectives: The primary aim of this cross-sectional study was to investigate the association between prosthesis design and peri-implant mucosa dimensions and morphology. The secondary aim was to investigate associations between mucosal dimensions and the presence of mucositis.
Materials And Methods: Forty-seven patients with 103 posterior bone level implants underwent clinical and radiographic examination, including cone beam computer tomography and intraoral optical scanning.
Statement Of Problem: Dental implants are particularly susceptible to occlusal overloading because, unlike natural teeth, they lack a periodontal ligament to help absorb occlusal forces. However, studies evaluating the impact of different crown and luting materials on the damping behavior and strain distribution of implant-supported crowns are lacking.
Purpose: The purpose of this in vitro study was to investigate the damping behavior and strain distribution of peri-implant bone associated with 5 different CAD-CAM implant-supported crowns and 3 luting materials.
Aim: To compare the removal torque loss (RTL) percentage of screw-retained, cement-retained, and combined screw- and cement-retained implant-supported crowns after cyclic loading and measure the impact of cyclic loading on removal torque.
Materials And Methods: Thirty-two dental implants (4.0 × 10 mm) in resin blocks and abutments were divided into four groups ( = 8) based on restoration design: combined screw- and cement-retained group (SC), two cement-retained groups: cemented with adhesive resin cement (AR) (Panavia V5) or provisional cement (PR) (RelyX Temp NE), and screw-retained one-piece titanium group (TI).
This study aimed to evaluate the thermocycling effect on the retentive force of 3 different retentive inserts in 3 denture attachments (Blue, Pink, Clear retentive inserts in LOCATOR; Blue, Pink, Clear retentive inserts in LOCATOR R-Tx; and White, Yellow, Green retentive inserts in Novaloc) (n=10). Maximum retentive force of each retentive insert was evaluated at baseline, 7-day water storage, and after 5,000-, and 10,000- cycle thermocycling. The water absorption percentage of the retentive inserts was also determined.
View Article and Find Full Text PDFObjectives: The aim of this study was to investigate the association of the Mucosal Emergence Angle (MEA) with peri-implant tissue mucositis.
Material And Methods: Forty-seven patients with 103 posterior bone level implants underwent clinical and radiographic examination. Three-dimensional data from Cone Bean Computer Tomography and Optica Scan were transposed.
Objective: To compare implant accuracy of combined static and dynamic (SD) computer-assisted implant surgery (CAIS) with static (S), dynamic (D) CAIS, and freehand surgery (FH) for single implant placement.
Materials And Methods: One hundred and twenty patients were randomized into four groups. Implants were placed using both stereolithographic surgical guide and dynamic navigation in the SD group, stereolithographic surgical guide in S group, dynamic navigation in D group, and conventional freehand in FH group.
Statement Of Problem: Daily denture brushing results in wear on implant-retained overdenture attachments. However, studies on the remaining denture attachment retention after brushing are lacking.
Purpose: The purpose of this in vitro study was to evaluate the retentive force of the retentive inserts in 3 denture attachments after brushing with different media.
This study evaluated the antifungal, physical, and mechanical properties of tissue conditioner incorporated with different amounts of zinc oxide nanoparticles (ZnOnps) at different storage times (0, 7, and 14 days). Specimens of 0, 5, 10, 15 wt% ZnOnps, or 15 wt% nystatin incorporated into tissue conditioner were fabricated (control, 5Zn, 10Zn, 15Zn, and Nys). The direct contact test (n=6) was performed to evaluate the antifungal effect against C.
View Article and Find Full Text PDFStatement Of Problem: The masticatory ability of complete denture (CD) wearers can be evaluated subjectively and objectively. Although an objective measure reflects a person's ability to masticate food, it is rarely used in clinical practice. Moreover, the factors associated with subjective and objective masticatory ability of CD wearers remain unclear.
View Article and Find Full Text PDFPurpose: This study investigated denture and patient related factors associated with oral health-related quality of life (OHRQoL) of complete denture wearers and their association with general health and happiness.
Methods: This retrospective cohort study comprised 130 participants with complete edentulism, with maxillary and mandibular complete dentures treated at Chulalongkorn University Dental School during 2010-2017. The primary outcome was the presence of overall and domain-specific Oral Impacts on Daily Performances (OIDP).
This study aimed to investigate amount of γ-methacryloxypropyltrimethoxysilane (MPS) silanized on experimental nanosilica particles (NPs), amount of NP and amount of MPS silanized NP on flexural strength (FS), flexural modulus (FM), and fracture toughness (FT) of NP reinforced polymethyl methacrylate (PMMA). The chemisorbed amount of MPS was determined using elemental analysis. Six groups (n=8) were prepared with chemisorbed amount and mixed with PMMA-monomer to make 0.
View Article and Find Full Text PDFThis study evaluated the effects of surface pretreatment with different concentrations of sulfuric acid etching on surface properties and bonding between Polyetheretherketone (PEEK) and a resin composite. Six groups of surface pretreatment (no pretreatment, etched with 70, 80, 85, 90, and 98% sulfuric acid for 60 s) were treated on PEEK. Surface roughness, scanning electron microscopy (SEM) and atomic force microscopy (AFM) analyses were examined.
View Article and Find Full Text PDFStatement Of Problem: Some complete denture wearers report difficulty with daily activities, especially activities related to denture retention and stability. However, no standard criteria are available for professionally based assessment of complete denture quality.
Purpose: The purpose of this clinical study was to determine the association between professionally based assessment of complete denture quality, evaluated by conventional and Chulalongkorn University (CU)-modified Kapur criteria and multiple patient-based outcomes: oral health-related quality of life (OHRQoL), eating satisfaction, and masticatory performance.
Mechanical force induces an efflux of ATP that regulates osteoblast differentiation. However, the effect of mechanical force-induced ATP efflux on WNT/β-catenin signaling remains unclarified. The aim of this study was to investigate the effect of intermittent compressive force (ICF) and ICF-induced extracellular ATP on osteoblast differentiation via WNT/β-catenin signaling in human mandibular-derived osteoblast precursors (hMOBPs).
View Article and Find Full Text PDFPurposes: The purposes of the present study were to examine the pressure transmission area and maximum pressure transmission of thermoplastic resin denture base materials under an impact load, and to evaluate the modulus of elasticity and nanohardness of thermoplastic resin denture base.
Methods: Three injection-molded thermoplastic resin denture base materials [polycarbonate (Basis PC), ethylene propylene (Duraflex), and polyamide (Valplast)] and one conventional heat-polymerized acrylic resin (PMMA, SR Triplex Hot) denture base, all with a mandibular first molar acrylic resin denture tooth set in were evaluated (n=6). Pressure transmission area and maximum pressure transmission of the specimens under an impact load were observed by using pressure-sensitive sheets.
Objective: Purinergic 2X7 receptor (P2X7R) activation modulates in vitro mineralization by primary rat and human osteoblasts. However, the detailed mechanism of how P2X7R activation affects primary human osteoblasts remains unclear. The aim of this study was to investigate the effect of P2X7R activation on human mandibular-derived osteoblast (hMOB) differentiation.
View Article and Find Full Text PDFBackground: Fungal infected denture, which is typically composed of polymethylmethacrylate (PMMA), is a common problem for a denture wearer, especially an elderly patient with limited manual dexterity. Therefore, increasing the antifungal effect of denture by incorporating surface modification nanoparticles into the PMMA, while retaining its mechanical properties, is of interest.
Aim Of The Study: This study aimed to evaluate antifungal, optical, and mechanical properties of heat-cured PMMA incorporated with different amounts of zinc oxide nanoparticles (ZnOnps) with or without methacryloxypropyltrimethoxysilane modification.
Objectives: This study evaluated color differences (Δs) and translucency parameter changes (Δs) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee.
Materials And Methods: Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE values of 2.
This study evaluated the effect of surface pretreatments on resin composite bonding to polyetheretherketone (PEEK). Four groups of surface pretreatment (no pretreatment, etched with 98% sulfuric acid, etched with piranha solution and sandblasting with 50 µm alumina) were performed on PEEK. Surface roughness, Scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) analysis were examined.
View Article and Find Full Text PDFThis study aimed to evaluate the effect of an acidic-adjusted pH of solvent in silanization on the amount of fluoride released and mechanical properties of heat-cured acrylic resin containing a silanized fluoride-releasing filler. The experimental groups were divided into 4 groups; non-silanized, acidic-adjusted pH, non-adjusted pH, and no filler as control. For fluoride measurement, each specimen was placed in deionized water which was changed every day for 7 days, every week for 7 weeks and measured.
View Article and Find Full Text PDFThis study investigated the surface roughness and gloss of composite resin CAD/CAM blocks after toothbrushing. Five composite resin blocks (Block HC, Cerasmart, Gradia Block, KZR-CAD Hybrid Resin Block, and Lava Ultimate), one hybrid ceramic (Vita Enamic), one feldspar ceramic (Vitablocs Mark II), one PMMA block (Telio CAD), and one conventional composite resin (Filtek Z350 XT) were evaluated. Surface roughness (Ra) and gloss were determined for each group of materials (n=6) after silicon carbide paper (P4000) grinding, 10k, 20k, and 40k toothbrushing cycles.
View Article and Find Full Text PDFUnlabelled: The aim of the study was to investigate two- and three-body wear of CAD/CAM blocks. Four composite resins, one hybrid ceramic and one feldspar ceramic block material were examined. Six specimens each were tested in a ball-on-disc wear device fitted with a zirconia ball (50 N load, 1.
View Article and Find Full Text PDFThis study compared commercial composite resin blocks with one ceramic block for use in computer-aided design/computer aided manufacturing (CAD/CAM). Four composite resins, one composite ceramic, and one feldspar-ceramic block were investigated. Flexural strength (FS), flexural modulus (FM), and Vickers hardness (VH) were determined under three conditions: dry storage; immersion in water at 37°C for 7 days; and immersion in water at 37°C for 7 days followed by 10,000 thermocycles.
View Article and Find Full Text PDF