Publications by authors named "Manger R"

Purpose: The focal radiation therapy (RT) boost technique was shown in a phase III randomized controlled trial (RCT) to improve prostate cancer outcomes without increasing toxicity. This technique relies on the accurate delineation of prostate tumors on MRI. A recent prospective study evaluated radiation oncologists' accuracy when asked to delineate prostate tumors on MRI and demonstrated high variability in tumor contours.

View Article and Find Full Text PDF

Purpose: To compare the superficial dose when using brass mesh bolus (BMB), no bolus, or 3 mm tissue-equivalent bolus with a pseudo-flash volumetric modulated arc therapy (VMAT) breast treatment planning technique.

Methods: Two different beam arrangements for right-sided irradiation and one beam arrangement for bilateral irradiation were planned on an inhomogeneous thorax phantom in accordance with our clinical practice for VMAT postmastectomy radiotherapy (PMRT). Plans were optimized using pseudo-flash and representative critical organ optimization structures were used to shape the dose.

View Article and Find Full Text PDF

Specific absorbed fractions (SAFs) are key components in the workflow of internal exposure assessment following the intake of a radionuclide, allowing quick conversion of particle energy released in a source region to the expected absorbed dose in target regions throughout the body. For data completeness, SAFs for spontaneous fission neutron emitters are currently needed for the recently adopted ICRP reference pediatric voxel phantom series. With 77 source regions within each reference individual and 28 radionuclides decaying via spontaneous fission, full Monte Carlo simulation requires significant computation time.

View Article and Find Full Text PDF

Purpose: To assess the dosimetric performance of an automated breast planning software.

Methods: We retrospectively reviewed 15 breast cancer patients treated with tangent fields according to the RTOG 1005 protocol and 30 patients treated off-protocol. Planning with electronic compensators (eComps) via manual, iterative fluence editing was compared to an automated planning program called EZFluence (EZF) (Radformation, Inc.

View Article and Find Full Text PDF

Purpose: Failure modes and effects analysis (FMEA) is a prospective risk assessment tool for identifying failure modes in equipment or processes and informing the design of quality control systems. This work aims to benchmark the performance of FMEAs for electronic brachytherapy (eBT) of the skin and for breast by comparing predicted versus actual failure modes reported in multiple incident learning systems (ILS).

Methods And Materials: Two public and our institution's internal ILS were queried for Xoft Axxent eBT-related events over 9 years.

View Article and Find Full Text PDF
Article Synopsis
  • - Ciguatoxins (CTXs) are neurotoxins causing ciguatera fish poisoning (CFP), primarily linked to contaminated fish in regions like the Pacific, Caribbean, and Indian coasts, with recent occurrences reported in Europe.
  • - A murine neuroblastoma cell line (N2a) has been used to test these toxins by examining their effects on voltage-gated sodium channels, demonstrating sensitivity for detecting CTXs at low levels.
  • - This research aims to refine the N2a-MTT method for accurately determining CTXs in fish, focusing on minimizing matrix effects, especially those from high lipid content.
View Article and Find Full Text PDF

Background: The treatment of lung lesions with stereotactic body radiation therapy calls for highly conformal dose, which is evaluated by a number of metrics. Lung stereotactic body radiation therapy clinical trials constrain a plans gradient index. The purpose of this work is to describe the dependence of clinically achievable dose gradient on planning target volume.

View Article and Find Full Text PDF

Purpose: To assess the performance of routine cone-beam computed tomography (CBCT) quality assurance (QA) at predicting and diagnosing clinically recognizable linac CBCT image quality issues.

Methods: Monthly automated linac CBCT image quality QA data were acquired on eight Varian linacs (Varian Medical Systems, Palo Alto, CA) using the CATPHAN 500 series phantom (The Phantom Laboratory, Inc., Greenwich, NY) and Total QA software (Image Owl, Inc.

View Article and Find Full Text PDF

Purpose: To evaluate the process and improve safety of intraoperative radiation therapy (IORT) for early-stage breast cancers treated with electronic brachytherapy.

Methods And Materials: A multidisciplinary team conducted a failure mode and effects analysis (FMEA) for IORT breast cancer treatments by first developing a process map. This map was then used to identify failure modes for all steps in the treatment workflow.

View Article and Find Full Text PDF

The objective of this study was to translate reaction conditions and quality control methods used for production of an astatine-211(211At)-labeled anti-CD45 monoclonal antibody (MAb) conjugate, 211At-BC8-B10, from the laboratory setting to cGMP production. Five separate materials were produced in the preparation of 211At-BC8-B10: (1) p-isothiocyanato-phenethyl-closo-decaborate(2-) (B10-NCS), (2) anti-CD45 MAb, BC8, (3) BC8-B10 MAb conjugate, (4) [211At]NaAt, and (5) 211At-BC8-B10. The 211At-labeling reagent, B10-NCS, was synthesized as previously reported.

View Article and Find Full Text PDF

Purpose: To develop an improved Xoft electronic skin brachytherapy process and identify areas of further improvement.

Methods And Materials: A multidisciplinary team conducted a failure modes and effects analysis (FMEA) by developing a process map and a corresponding list of failure modes. The failure modes were scored for their occurrence, severity, and detectability, and a risk priority number (RPN) was calculated for each failure mode as the product of occurrence, severity, and detectability.

View Article and Find Full Text PDF

Research demonstrates that instructing patients to have a full bladder for pelvic radiotherapy results in highly variable bladder volumes at daily treatment. We aimed to determine bladder volume variation in patients with intact cervical cancer treated with intensity-modulated radiotherapy (IMRT) on an empty bladder and estimate the difference in radiation dose to the small bowel compared to treating on a full bladder. We identified 29 patients treated with IMRT from 2010 to 2013 who underwent 2 planning computed tomography (CT) scans, 1 with a full bladder followed by 1 with an empty bladder.

View Article and Find Full Text PDF

Purpose: To implement the DMAIC (Define-Measure-Analyze-Improve-Control) can be used for customizing the patient-specific QA by designing site-specific range tolerances.

Methods: The DMAIC framework (process flow diagram, cause and effect, Pareto chart, control chart, and capability analysis) were utilized to determine the steps that need focus for improving the patient-specific QA. The patient-specific range QA plans were selected according to seven treatment site groups, a total of 1437 cases.

View Article and Find Full Text PDF

The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils.

View Article and Find Full Text PDF

AlignRT is a surface imaging system that has been utilized for localizing and tracking patient position during radiotherapy. AlignRT has two calibration procedures that can set the system's isocenter called "Monthly Calibration" (MC) and "Isocentre Calibration" (IC). The MC utilizes a calibration plate.

View Article and Find Full Text PDF

Brass mesh bolus has been shown to be an acceptable substitute for tissue-equivalent bolus to increase superficial dose for chest wall tangent photon radiotherapy. This work investigated the increase in surface dose, the change in the dose at depth, and the safety implications of higher energy photon beams when using brass mesh bolus for postmastectomy chest wall radiotherapy. A photon tangent plan was delivered to a thorax phantom, and the superficial dose ranged from 40%-72% of prescription dose with no bolus.

View Article and Find Full Text PDF

Purpose: To examine the abilities of a traditional failure mode and effects analysis (FMEA) and modified healthcare FMEA (m-HFMEA) scoring methods by comparing the degree of congruence in identifying high risk failures.

Methods: The authors applied two prospective methods of the quality management to surface image guided, linac-based radiosurgery (SIG-RS). For the traditional FMEA, decisions on how to improve an operation were based on the risk priority number (RPN).

View Article and Find Full Text PDF

Dose coefficients for assessment of internal exposures to radionuclides are radiological protection quantities giving either the organ equivalent dose or effective dose per intake of radionuclide following ingestion or inhalation. In the International Commission on Radiological Protection’s (ICRP) Occupational Intakes of Radionuclides (OIR) publication series, new biokinetic models for distribution of internalised radionuclides in the human body are presented as needed for establishing time-integrated activity within organs of deposition (source regions). This series of publications replaces Publications 30 and 68 (ICRP, 1979, 1980, 1981, 1988, 1994b).

View Article and Find Full Text PDF

Purpose: Both humans and software are notoriously challenging to account for in traditional hazard analysis models. The purpose of this work is to investigate and demonstrate the application of a new, extended accident causality model, called systems theoretic accident model and processes (STAMP), to radiation oncology. Specifically, a hazard analysis technique based on STAMP, system-theoretic process analysis (STPA), is used to perform a hazard analysis.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the increased dose near the skin from an electromagnetic surface beacon transponder, which is used for localization and tracking organ motion. The bolus effect due to the copper coil surface beacon was evaluated with radiographic film measurements and Monte Carlo simulations. Various beam incidence angles were evaluated for both 6 MV and 18 MV experimentally.

View Article and Find Full Text PDF

Purpose: Surface image guided, Linac-based radiosurgery (SIG-RS) is a modern approach for delivering radiosurgery that utilizes optical stereoscopic imaging to monitor the surface of the patient during treatment in lieu of using a head frame for patient immobilization. Considering the novelty of the SIG-RS approach and the severity of errors associated with delivery of large doses per fraction, a risk assessment should be conducted to identify potential hazards, determine their causes, and formulate mitigation strategies. The purpose of this work is to investigate SIG-RS using the combined application of failure modes and effects analysis (FMEA) and fault tree analysis (FTA), report on the effort required to complete the analysis, and evaluate the use of FTA in conjunction with FMEA.

View Article and Find Full Text PDF

Background: The German NOTES registry (GNR) was initiated by the German Society for General and Visceral Surgery (DGAV) as a treatment and outcome database for natural orifice transluminal endoscopic surgery (NOTES).

Aim: The aim of this study was the descriptive analysis of all GNR data collected over a 5-year period since its start in 2008 with more than 3000 interventions.

Material And Methods: The GNR is an online database with voluntary participation available to all German-speaking clinics.

View Article and Find Full Text PDF

Ciguatoxins are potent neurotoxins with a significant public health impact. Cytotoxicity assays have allowed the most sensitive means of detection of ciguatoxin-like activity without reliance on mouse bioassays and have been invaluable in studying outbreaks. An improvement of these cell-based assays is presented here in which rapid flow cytometric detection of ciguatoxins and saxitoxins is demonstrated using fluorescent voltage sensitive dyes.

View Article and Find Full Text PDF

We have developed a technology that depletes the complement regulatory protein (CRP) CD46 from the cell surface, and thereby sensitizes tumor cells to complement-dependent cytotoxicity triggered by therapeutic monoclonal antibodies (mAbs). This technology is based on a small recombinant protein, Ad35K++, which induces the internalization and subsequent degradation of CD46. In preliminary studies, we had demonstrated the utility of the combination of Ad35K++ and several commercially available mAbs such as rituximab, alemtuzumab, and trastuzumab in enhancing cell killing in vitro as well as in vivo in murine xenograft and syngeneic tumor models.

View Article and Find Full Text PDF