Publications by authors named "Manda Svabic Kolacio"

Background: Study determines differences in calculated dose distributions for non-small cell lung carcinoma (NSC LC) patients. NSC LC cases were investigated, being the most common lung cancer treated by radiotherapy in our clinical practice.

Materials And Methods: A retrospective study of 15 NSCLC patient dose distributions originally calculated using standard superposition (SS) and recalculated using collapsed cone (CC ) and Monte Carlo (MC) based algorithm expressed as dose to medium in medium (MCD) and dose to water in medium (MCD) was performed so that prescribed dose covers at least 99% of the gross target volume (GTV).

View Article and Find Full Text PDF

Objective: To present results of the first national survey on reference levels of CT imaging performed for the treatment planning purposes in radiation oncology in Croatia.

Methods: Data for CT protocols of five anatomical regions including head, head and neck, pelvis, breast, and thorax were collected at eight radiation oncology departments in Croatia. Data included volume CT dose index (CTDI), dose-length product (DLP), scan length and set of acquisition and reconstruction parameters.

View Article and Find Full Text PDF

Introduction Advanced, Monte Carlo (MC) based dose calculation algorithms, determine absorbed dose as dose to medium-in-medium (Dm,m) or dose to water-in-medium (Dw,m). Some earlier studies identified the differences in the absorbed doses related to the calculation mode, especially in the bone density equivalent (BDE) media. Since the calculation algorithms built in the treatment planning systems (TPS) should be dosimetrically verified before their use, we analyzed dose differences between two calculation modes for the Elekta Monaco TPS.

View Article and Find Full Text PDF

Background The accuracy of dose calculation is crucial for success of the radiotherapy treatment. One of the methods that represent the current standard for patient-specific dosimetry is the evaluation of dose distributions measured with an ionization chamber array inside a homogeneous phantom using gamma method. Nevertheless, this method does not replicate the realistic conditions present when a patient is undergoing therapy.

View Article and Find Full Text PDF

Advanced dose calculation algorithms for radiation therapy treatment planning can report external beam photon dose 2-sided, in terms of dose-to-medium (D) and dose-to-water (D). The purpose of our study was to determinate the effect of D and D reporting modes built in Elekta Monaco treatment planning system on intensity-modulated radiotherapy dose distributions for patients with nasopharyngeal cancer. For 13 patients involved in this retrospective study, 2 plans were created: 1 using D and another according to D reporting mode.

View Article and Find Full Text PDF