This study aimed to evaluate the dose reduction using gonad shielding (GS) during pelvic imaging. Three types of pelvic images (radiography, magnetic resonance and computed tomography) were fused to elucidate the three-dimensional relationship between the position of ovaries and GS. To estimate the dose received by the ovaries, the off-axis dose at any given depth was measured under two different imaging conditions using thermoluminescence dosemeters and a polymethyl methacrylate phantom.

View Article and Find Full Text PDF

Purpose: To evaluate the applicability of TRS-483 output correction factors (CFs) for small-field output factors (OFs) using different multi-leaf collimators (MLC) and field-shaping types.

Methods: All measurements were performed on TrueBeam, TrueBeam STx, and Halcyon using 6 MV flattening filter-free energy. Four detectors, including CC01, CC04, microDiamond, and EDGE, were used.

View Article and Find Full Text PDF

This study aimed to assess the effectiveness of a new patient-setup procedure using surface-guided imaging during the coronavirus disease 2019 (COVID-19) pandemic for left-sided whole-breast irradiation with deep inspiration breath-hold. Two setup procedures were compared regarding patient positioning accuracy for the first 22 patients. The first was a traditional setup (T-setup) procedure that used a surface-guided system after patient setup with traditional skin marks and lasers.

View Article and Find Full Text PDF

The purpose of this study was to retrospectively assess target localization accuracy across different soft-tissue matching protocols using cone-beam computed tomography (CBCT) in a large sample of patients with pancreatic cancer and to estimate the optimal margin size for each protocol. Fifty-four consecutive patients with pancreatic cancer who underwent 15-fraction volumetric modulated arc therapy under the end-exhalation breath-hold condition were enrolled. Two soft-tissue matching protocols were used according to the resectability classification, including gross tumor volume (GTV) matching for potentially resectable tumors and planning target volume (PTV) matching for borderline resectable or unresectable tumors.

View Article and Find Full Text PDF

Background: Small-field dosimetry is challenging for radiotherapy dosimetry because of the loss of lateral charged equilibrium, partial occlusion of the primary photon source by the collimating devices, perturbation effects caused by the detector materials and their design, and the detector size relative to the radiation field size, which leads to a volume averaging effect. Therefore, a suitable tool for small-field dosimetry requires high spatial resolution, tissue equivalence, angular independence, and energy and dose rate independence to achieve sufficient accuracy. Recently, with the increasing use of combinations of coplanar and non-coplanar beams for small-field dosimetry, there is a need to clarify angular dependence for dosimetry where the detector is oriented at various angles to the incident beam.

View Article and Find Full Text PDF

The information of definitive radiotherapy for a pregnant woman with malignancy was limited; however, it was reported to be potentially feasible with minimal risks. We performed definitive chemoradiotherapy for a pregnant woman with locally advanced cervical esophageal cancer. Feasibility of radiotherapy and safety of fetus were confirmed by the phantom study estimating fetal dose, and monitoring it in each radiotherapy session.

View Article and Find Full Text PDF

Purpose: It has been reported that the placement of protective equipment in female pelvic radiography is predominantly inadequate compared with that of male. We analyzed the actual situation of ovarian shielding by protective devices using X-ray, CT, and MR images obtained in the past, and evaluated the effectiveness of gonadal protection in female hip radiography.

Methods: The ovaries were contoured in MR images and the pelvic bone was extracted by CT images.

View Article and Find Full Text PDF

Purpose: To evaluate the displacement of gross tumor volume (GTV) positions caused by intrafractional residual setup errors (RSEs) and to accumulate delivered dose distributions considering intrafraction RSEs in fractionated-stereotactic radiotherapy (f-SRT) with single isocenter volumetric modulated arc therapy (SI-VMAT) for multiple brain metastases.

Methods: Overall, 72 consecutive patients who underwent f-SRT with SI-VMAT for multiple brain metastases were included. For all patients, 6D correction was performed using the ExacTrac X-ray (ETX) system.

View Article and Find Full Text PDF

Purpose: To evaluate intrafractional head motion (IFM) in patients who underwent intracranial stereotactic radiosurgery with the ExacTrac X-ray system (ETX) and a frameless mask.

Methods: A total of 143 patients who completed a pre-treatment examination for IFM were eligible for this study. The frameless mask type B R408 (Klarity Medical & Equipment Co.

View Article and Find Full Text PDF

The purpose of this study was to investigate other indices estimating absorbed dose for eye lens and brain, using clinical images of East Asian pediatric patients. We simulated head computed tomography (CT ) examinations in 104 pediatric patients. Effective diameter (deff) and water equivalent diameter (dw) were measured on clinical images.

View Article and Find Full Text PDF

Splenic artery aneurysm (SAA) is a relatively rare disease. Most patients with SAA have no symptoms, and detection is incidental detection. The incidence of rupture is not particularly high, but the mortality rate of ruptured SAAs is high.

View Article and Find Full Text PDF

The purpose of this study was to assess the positional repeatability of internal and external markers among multiple breath-hold (BH) sessions and evaluate the positional variation of these markers within BH sessions for volumetric-modulated arc therapy (VMAT) for pancreatic cancer patients. A total of 13 consecutive pancreatic cancer patients with an internal marker were enrolled. Single full-arc coplanar VMAT was delivered under end-exhalation BH conditions while monitoring the internal marker with kilovoltage (kV) X-ray fluoroscopy.

View Article and Find Full Text PDF

This study aimed to examine the effects of batting practice and visual training focused on the pitch type and speed on batting ability and visual function. A total of 46 participants took part in 12 training sessions for 4 weeks. The participants were divided into six groups according to the training type as follows: Group 1, batting practice with a fastball at 100 km/h; Group 2, tracking (watching) a fastball at 100 km/h; Group 3, batting practice with a fastball at 115 km/h; Group 4, tracking a fastball at 115 km/h; Group 5, batting practice with a curve ball at 100 km/h; and Group 6, tracking a curve ball at 100 km/h.

View Article and Find Full Text PDF

Purpose: To assess the effects of different beam starting phases on dosimetric variations in the clinical target volume (CTV) and organs at risk (OARs), and to identify the relationship between plan complexity and the dosimetric impact of interplay effects in volumetric-modulated arc therapy (VMAT) plans for pancreatic cancer.

Methods: Single and double full-arc VMAT plans were generated for 11 patients. A dose of 50.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the discrepancy between the monitor unit (MU) calculated by different dose normalization methods in the electron Monte Carlo (eMC) algorithm and the conventional manual MU. In the water phantom condition, the manual MU obtained from the measured output factor was compared with the calculated MU by the eMC algorithm, using 24 different irradiation field shapes and several different energies of electron beam. In the breast boost condition, calculated MUs by both calculation methods were evaluated for 45 cases.

View Article and Find Full Text PDF
Article Synopsis
  • - The study examined how translational and rotational setup errors impact 3D dose distribution in spine stereotactic body radiotherapy, using gamma index and dose volumetric indices to analyze the effects on treatment plans based on RTOG 0631 protocol.
  • - Setup errors were generated and tested using specialized equipment, including a Delta4 phantom and HexaMotion 6D platform, to determine the correlation between γ passing rates and specific dose metrics for both the target volume and spinal cord.
  • - Results indicated that a 2° rotational error is equivalent to a 2mm translational error for several metrics, identifying that the target volume and spinal cord had varying sensitivities to specific types of setup errors, emphasizing the need for
View Article and Find Full Text PDF
Article Synopsis
  • The purpose of the study was to verify the accuracy of lung stereotactic body radiotherapy (SBRT) plans using a secondary treatment planning system (TPS) and to establish tolerance levels between the primary and secondary TPSs.
  • The research involved recalculating dose distributions from 147 lung SBRT plans using two different algorithms (Acuros XB and anisotropic analytical algorithm) to compare results against a primary method (X-ray voxel Monte Carlo).
  • Results showed that the Acuros XB values closely matched those of the primary method within a 3.5% margin, while the anisotropic analytical algorithm tended to overestimate doses, indicating that Acuros XB is a more reliable tool for independent verification of dosimetric calculations.
View Article and Find Full Text PDF

Purpose: We evaluated three-dimensional intrafractional target motion, divided into respiratory-induced motion and baseline drift, in accelerated partial breast irradiation (APBI).

Methods: Paired fluoroscopic images were acquired simultaneously using orthogonal kV X-ray imaging systems at pre- and post-treatment for 23 patients who underwent APBI with external beam radiotherapy. The internal target motion was calculated from the surgical clips placed around the tumour cavity.

View Article and Find Full Text PDF

In external radiotherapy, the X-ray beam passes through the treatment couch, leading to the dose reduction by the attenuation of the couch. As a method to compensate for the reduction, radiation treatment planning systems (RTPS) support virtual couch function, namely "couch modeling method". In the couch modeling method, the computed tomography (CT) numbers assigned to each structure should be optimized by comparing calculations to measurements for accurate dose calculation.

View Article and Find Full Text PDF

A uterine artery pseudoaneurysm (UAP) can occur after a traumatic event to the uterus, and cause massive bleeding. A uterine manipulator has been widely used for gynecologic laparoscopic surgery as basically an atraumatic instrument. We describe here a woman with a UAP caused by a uterine manipulator.

View Article and Find Full Text PDF

It is generally known that the dose distribution around the high-density materials is not accurate with commercially available radiation treatment planning systems (RTPS). Recently, Acuros XB (AXB) has been clinically available for dose calculation algorithm. The AXB is based on the linear Boltzmann transport equation - the governing equation - that describes the distribution of radiation particles resulting from their interactions with matter.

View Article and Find Full Text PDF

In this study, we assessed the differences in the dose distribution of a 4 MV photon beam among different calculation algorithms: the Acuros XB (AXB) algorithm, the analytic anisotropic algorithm (AAA), and the pencil beam convolution (PBC) algorithm (ver. 11.0.

View Article and Find Full Text PDF

We assessed interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography at end-exhalation (EE) with visual feedback (BH-CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity-modulated radiation therapy with visual feedback were enrolled. All participating patients stopped oral intake, with the exception of drugs and water, for > 3 hr before treatment planning and daily treatment.

View Article and Find Full Text PDF

Purpose: To compare the dosimetric performance of Acuros XB (AXB), anisotropic analytical algorithm (AAA), and x-ray voxel Monte Carlo (XVMC) in heterogeneous phantoms and lung stereotactic body radiotherapy (SBRT) plans.

Methods: Water- and lung-equivalent phantoms were combined to evaluate the percentage depth dose and dose profile. The radiation treatment machine Novalis (BrainLab AG, Feldkirchen, Germany) with an x-ray beam energy of 6 MV was used to calculate the doses in the composite phantom at a source-to-surface distance of 100 cm with a gantry angle of 0°.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session08b4q7jtt3sksh4v34va1b84gsc3i0sn): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once