Purpose: The purpose of our study was to evaluate the interocular symmetry and distribution of peripapillary vessel density in young myopic eyes.
Methods: A cross-sectional observational study was designed. A total of 174 eyes of 87 young myopic patients were recruited in this study.
To investigate the effects of diabetes on the biomechanical behavior of cornea in alloxan-induced diabetic rabbits. Diabetes mellitus (DM) was induced in 20 rabbits using alloxan, while another 20 age- and weight-matched non-diabetic rabbits served as controls. Eyes were enucleated after 8 weeks of inducing diabetes and the whole cornea was removed with a 3 mm wide scleral ring and tested under inflation conditions with an internal pressure range of 2.
View Article and Find Full Text PDFPurpose: To evaluate the effectiveness of methods to correct intraocular pressure (IOP) measurements obtained using the Goldmann applanation tonometer (GAT), the ocular response analyzer (ORA), and the Corvis ST tonometer (CVS) for the effects of corneal stiffness parameters: central corneal thickness (CCT), corneal curvature (R), and age in a Chinese population.
Patients And Methods: Data were collected for 99 eyes of 99 participants. Whereas cornea-corrected IOP was obtained directly from ORA (ORA-IOPcc), cornea correction in GAT and CVS was implemented using multiparameter equations developed earlier.
Purpose: To improve the reliability of corneal topographic data through the development of a method to estimate the magnitude of misalignment between successive corneal videokeratography (VK) maps and eliminate the effect of misalignment on the repeatability of topography data.
Methods: Anterior and posterior topography maps were recorded twice for 124 healthy eyes of 124 participants using a Pentacam, and the repeatability of measurements was assessed by calculating the differences in elevation between each two sets of data. The repeatability of measurements was re-assessed following the determination of the magnitude of misalignment components (translational displacements: x0, y0 and z0, and rotational displacements: α, β and γ) between each two data sets and using them to modify the second data set within each pair based on an Iterative Closest Point (ICP) algorithm.
The purpose was to assess the suitability of quadratic equations for the accurate representation of corneal topography and consider the effect of translation and rotation fitting on the quality of fit and the curvature results. Topography images were recorded for the anterior and posterior surfaces of 490 corneas of 490 myopic patients using Pentacam. Elevation data were fitted to four shape models, three of which considered translational and/or rotational fitting.
View Article and Find Full Text PDFThe relationship of corneal biomechanical metrics provided by the Ocular Response Analyzer (ORA) and Corvis ST (CVS) with physical intraocular pressure (IOPp) and central corneal thickness (CCT) was evaluated. Thirty fresh enucleated eyes of 30 rabbits were used in ex vivo whole globe inflation experiments. IOPp was measured with a pressure transducer and increased from 7.
View Article and Find Full Text PDF