Publications by authors named "Mamou J"

The objective of this work is to address the need for versatile and effective tissue characterization in abdominal ultrasound diagnosis using a simpler system. We evaluated the backscattering coefficient (BSC) of several tissue-mimicking phantoms utilizing three different ultrasonic probes: a single-element transducer, a linear array probe for clinical use, and a laboratory-made annular array probe. The single-element transducer, commonly used in developing fundamental BSC evaluation methods, served as a benchmark.

View Article and Find Full Text PDF

Retina-derived growth signals relayed from the choroid to the sclera cause remodeling of the extracellular scleral matrix, resulting in myopic ocular elongation. However, to the best of our knowledge, no studies have assessed changes in choroidal stromal biomechanical properties during myopia progression. Here we utilized 7 µm-resolution scanning acoustic microscopy (SAM) to assess biomechanical properties (bulk modulus (K) and mass density (rho)) of choroidal stroma from guinea pig eyes with form-deprivation (FD) induced myopia.

View Article and Find Full Text PDF
Article Synopsis
  • * The study found that specific QUS parameters demonstrated high reliability and correlation with controlled attenuation parameter (CAP), indicating accurate assessment of liver fat levels.
  • * The research concludes that QUS can be effectively used on portable devices, offering a convenient method for large-scale screening and monitoring of liver fat.
View Article and Find Full Text PDF

Objective: A deep neural network (DNN) was trained to generate a multiparametric ultrasound (mpUS) volume from four input ultrasound-based modalities (acoustic radiation force impulse [ARFI] imaging, shear wave elasticity imaging [SWEI], quantitative ultrasound-midband fit [QUS-MF], and B-mode) for the detection of prostate cancer.

Methods: A DNN was trained using co-registered ARFI, SWEI, MF, and B-mode data obtained in men with biopsy-confirmed prostate cancer prior to radical prostatectomy (15 subjects, comprising 980,620 voxels). Data were obtained using a commercial scanner that was modified to allow user control of the acoustic beam sequences and provide access to the raw image data.

View Article and Find Full Text PDF

Chronic interstitial lung diseases (ILDs) require frequent point-of-care monitoring. X-ray-based methods lack resolution and are ionizing. Chest computerized tomographic (CT) scans are expensive and provide more radiation.

View Article and Find Full Text PDF

Media that contain ultrasound scatterers arranged in a regular spatial distribution can be considered as structured. Structural effects affect quantitative ultrasound parameters that reflect the microstructure properties. Prior studies examined structural effects using simulations or phantoms with fixed microarchitecture, focusing on a limited set of ultrasound parameters, with limited attention given to their underlying physical significance.

View Article and Find Full Text PDF

Background: A high-frequency point-of-care (POC) ultrasound instrument was used to evaluate the microstructural and biomechanical properties of the anterior sclera in vivo using parameters computed from quantitative ultrasound (QUS) methods.

Methods: In this cross-sectional study, both eyes of 85 enrolled patients were scanned with the POC instrument and ultrasound data were processed to obtain QUS parameters. Pearson correlation and multi-linear regression were used to identify relationships between QUS parameters and refractive error (RE) or axial length.

View Article and Find Full Text PDF

The double-Nakagami (DN) model provides a method for analyzing the amplitude envelope statistics of quantitative ultrasound (QUS). In this study, the relationship between the sound field characteristics and the robustness of QUS evaluation was evaluated using five HF linear array probes and tissue-mimicking phantoms. Compound plane-wave imaging (CPWI) was used to acquire echo data.

View Article and Find Full Text PDF

Chronic interstitial lung diseases (ILDs) require frequent point-of-care monitoring. X-ray-based methods lack resolution and are ionizing. Chest computerized tomographic (CT) scans are expensive and provide more radiation.

View Article and Find Full Text PDF

Objective: Gray-scale ultrasound (US) is the standard-of-care for evaluating thyroid nodules (TNs). However, the performance is better for the identification of hypoechoic malignant TNs (such as classic papillary thyroid cancer) than isoechoic malignant TNs. Quantitative ultrasound (QUS) utilizes information from raw ultrasonic radiofrequency (RF) echo signal to assess properties of tissue microarchitecture.

View Article and Find Full Text PDF

Purpose: Quantitative ultrasound (QUS) provides objective indices of Vision Degrading Myodesopsia (VDM) that correlate with contrast sensitivity (CS). To date, QUS methods were only tested on a single ultrasound machine. Here, we evaluate whether QUS measurements are machine independent.

View Article and Find Full Text PDF

Quantitative acoustic microscopy (QAM) reconstructs two-dimensional (2D) maps of the acoustic properties of thin tissue sections. Using ultrahigh frequency transducers (≥ 100 MHz), unstained, micron-thick tissue sections affixed to glass are raster scanned to collect radiofrequency (RF) echo data and generate parametric maps with resolution approximately equal to the ultrasound wavelength. 2D maps of speed of sound, mass density, acoustic impedance, bulk modulus, and acoustic attenuation provide unique and quantitative information that is complementary to typical optical microscopy modalities.

View Article and Find Full Text PDF

Purpose: To develop a point-of-care (POC) device using high-frequency ultrasound (US) for evaluating microstructural changes in the anterior sclera associated with myopia.

Methods: The proposed POC device must satisfy four primary requirements for effective clinical use: the measurement component is handheld; the software must be simple and provide real-time feedback; patient safety and health data security requirements set forth by relevant governing bodies must be satisfied and the measurement data must have sufficient signal-to-noise ratio (SNR) and repeatability. Radiofrequency (RF) echo data acquired by the POC device will be processed using our quantitative US methods to characterise tissue microstructure and biomechanical properties.

View Article and Find Full Text PDF

Purpose: Limited vitrectomy improves vision degrading myodesopsia, but the incidence of recurrent floaters postoperatively is not known. We studied patients with recurrent central floaters using ultrasonography and contrast sensitivity (CS) testing to characterize this subgroup and identify the clinical profile of patients at risk of recurrent floaters.

Methods: A total of 286 eyes (203 patients, 60.

View Article and Find Full Text PDF

Quantitative ultrasound (QUS) methods characterizing the backscattered echo signal have been of use in assessing tissue microstructure. High-frequency (30 MHz) QUS methods have been successful in detecting metastases in surgically excised lymph nodes (LNs), but limited evidence exists regarding the efficacy of QUS for evaluating LNs in vivo at clinical frequencies (2-10 MHz). In this study, a clinical scanner and 10-MHz linear probe were used to collect radiofrequency (RF) echo data of LNs in vivo from 19 cancer patients.

View Article and Find Full Text PDF

Large-scale international efforts to generate and analyze loss-of-function mutations in each of the approximately 20,000 protein-encoding gene mutations are ongoing using the "knockout" mouse as a model organism. Because one-third of gene knockouts are expected to result in embryonic lethality, it is important to develop non-invasive in utero imaging methods to detect and monitor mutant phenotypes in mouse embryos. We describe the utility of 3-D high-frequency (40-MHz) ultrasound (HFU) for longitudinal in utero imaging of mouse embryos between embryonic days (E) 11.

View Article and Find Full Text PDF
Article Synopsis
  • * A total of 46 individuals participated, and the algorithm processed 130 ultrasound images to analyze the posterior eyewall curvature and axial length.
  • * The algorithm showed strong diagnostic performance (AUROC > 0.70 for many parameters) and localized the staphyloma apex with a small error margin, making it a potential screening tool for in vivo detection.
View Article and Find Full Text PDF

Myopia alters the microstructural and biomechanical properties of the posterior sclera, which is characterized as a layered structure with potentially different inter-layer collagen fibril characteristics. Scanning acoustic microscopy (SAM) has been used to investigate how the micron-scale bulk mechanical properties of the posterior sclera are affected by myopia. Other investigators have employed second harmonic generation (SHG) imaging to characterize the collagen microstructure of tissues.

View Article and Find Full Text PDF

Purpose: Multifocal intraocular lenses (MFIOL) are associated with degradation in contrast sensitivity function (CSF); yet the contribution of vitreous is not known, nor is the benefit of vitrectomy.

Design: Prospective, nonrandomized clinical study.

Methods: A total of 180 eyes of 180 patients (55 MFIOL, 60 monofocal intraocular lenses [MIOL], 65 phakic) with symptomatic vitreous opacities were enrolled.

View Article and Find Full Text PDF

Quantitative ultrasound (QUS) assessment of osteoarthritis (OA) using high-frequency, research-grade single-element ultrasound systems has been reported. The objective of this ex vivo study was to assess the performance of QUS in detecting early OA using a high-frequency linear array transducer. Osteochondral plugs (n = 26) of human articular cartilage were scanned with ExactVu Micro-Ultrasound using an EV29L side-fire transducer.

View Article and Find Full Text PDF

Quantitative ultrasound methods based on the backscatter coefficient (BSC) and envelope statistics have been used to quantify disease in a wide variety of tissues, such as prostate, lymph nodes, breast, and thyroid. However, to date, these methods have not been investigated in the lung. In this study, lung properties were quantified by BSC and envelope statistical parameters in normal, fibrotic, and edematous rat lungs in vivo.

View Article and Find Full Text PDF

Background: Gray-scale, B-mode ultrasound (US) imaging is part of the standard clinical procedure for evaluating thyroid nodules (TNs). It is limited by its instrument- and operator-dependence and inter-observer variability. In addition, the accepted high-risk B-mode US TN features are more specific for detecting classic papillary thyroid cancer rather than the follicular variant of papillary thyroid cancer or follicular thyroid cancer.

View Article and Find Full Text PDF

Segmentation and mutant classification of high-frequency ultrasound (HFU) mouse embryo brain ventricle (BV) and body images can provide valuable information for developmental biologists. However, manual segmentation and identification of BV and body requires substantial time and expertise. This article proposes an accurate, efficient and explainable deep learning pipeline for automatic segmentation and classification of the BV and body.

View Article and Find Full Text PDF

The segmentation of the brain ventricle (BV) and body in embryonic mice high-frequency ultrasound (HFU) volumes can provide useful information for biological researchers. However, manual segmentation of the BV and body requires substantial time and expertise. This work proposes a novel deep learning based end-to-end auto-context refinement framework, consisting of two stages.

View Article and Find Full Text PDF

A better understanding of ultrasound scattering in a three-dimensional (3D) medium can provide more accurate methods for ultrasound tissue characterization. The possibility of using two-dimensional impedance maps (2DZMs) based on correlation coefficients has shown promise in the case of isotropic and sparse medium [Luchies and Oelze, J. Acoust.

View Article and Find Full Text PDF