Purpose: This study aimed to investigate intra- and interfraction motion during liver stereotactic body radiation therapy for the purpose of planning target volume (PTV) margin estimation, comparing deep inspiration breath hold (DIBH) and deep expiration breath hold (DEBH).
Methods And Materials: Pre- and posttreatment kV cone beam computed tomography (CT) images were acquired for patients with liver cancer who were treated using stereotactic body radiation therapy with DIBH or DEBH. A total of 188 images were analyzed from 18 patients.
Total body irradiation (TBI) is used prior to bone marrow transplantation as part of the conditioning regimen in selected patients. A linear accelerator-based technique was used at our treatment centre between June, 2004 and August, 2015. Patients were treated supine with extended source-to-surface distance (SSD) lateral fields, and prescription dose was 12 Gy delivered in six fractions, two fractions per day.
View Article and Find Full Text PDFThe two-dimensional (2D) ionization chamber array MatriXX Evolution is one of the 2D ionization chamber arrays developed by IBA Dosimetry (IBA Dosimetry, Germany) for megavoltage real-time absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT). The purpose of this study was to (1) evaluate the performance of ion chamber array for submegavoltage range brachytherapy beam dose verification and quality assurance (QA) and (2) use the end-to-end dosimetric evaluation that mimics a patient treatment procedure and confirm the primary source strength calibration agrees in both the treatment planning system (TPS) and treatment delivery console computers. The dose linearity and energy dependence of the 2D ion chamber array was studied using kilovoltage X-ray beams (100, 180 and 300 kVp).
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
July 2007
Purpose: The accuracy of intensity-modulated radiotherapy (IMRT) delivery may be compromised by random spatial error and systematic anatomic changes during the treatment course. We present quantitative measurements of the spatial variability of head-and-neck organs-at-risk and demonstrate the resultant dosimetric effects.
Methods And Materials: Fifteen consecutive patients were imaged weekly using computed tomography during the treatment course.
For patients with thoracic and abdominal lesions, respiration-induced internal organ motion and deformations during radiation therapy are limiting factors for the administration of high radiation dose. To increase the dose to the tumor and to reduce margins, tumor movement during treatment must be minimized. Currently, several types of breath-synchronized systems are in use.
View Article and Find Full Text PDF