Publications by authors named "Malkin C"

Background: Increasing demand for transcatheter aortic valve implantation (TAVI) places greater emphasis on the efficiency of pathways and services. A significant limitation to increasing TAVI capacity is the availability of cardiac catheterisation laboratory time. We have developed a novel complexity scoring system (TAVI ComplEXity; TEX score) which can aid in planning lists with appropriate case selection.

View Article and Find Full Text PDF

As the population ages and treatment options for heart valve disease increase, the number of patients with intracardiac valve prostheses is growing rapidly. Although all devices have the potential to cause thrombus formation, the propensity depends on the type of prosthesis as well as risk of the individual patient. Mechanical valve prostheses carry the highest (and persistent) risk of thromboembolism, and these patients require anticoagulation with vitamin K antagonists (warfarin).

View Article and Find Full Text PDF

This study sought to compare the morbidity and mortality of redo aortic valve replacement (redo-AVR) versus valve-in-valve trans-catheter aortic valve implantation (valve-in-valve TAVI) for patients with a failing bioprosthetic valve. A multicenter UK retrospective study of redo-AVR or valve-in-valve TAVI for patients referred for redo aortic valve intervention due to a degenerated aortic bioprosthesis. Propensity score matching was performed for confounding factors.

View Article and Find Full Text PDF

Background: With expansion of transcatheter aortic valve implantation (TAVI) into younger patients, valve durability is critically important.

Aims: We aimed to evaluate long-term valve function and incidence of severe structural valve deterioration (SVD) among patients ≥ 10-years post-TAVI and with echocardiographic follow-up at least 5-years postprocedure.

Methods: Data on patients who underwent TAVI from 2007 to 2011 were obtained from the UK TAVI registry.

View Article and Find Full Text PDF

Background: The prevalence, clinical characteristics, management and long-term outcomes of patients with atrial secondary mitral regurgitation (ASMR) are not well described.

Methods: We performed a retrospective, observational study of consecutive patients with grade III/IV MR determined by transthoracic echocardiography. The aetiology of MR was grouped as being either primary (due to degenerative mitral valve disease), ventricular SMR (VSMR: due to left ventricular dilatation/dysfunction), ASMR (due to LA dilatation), or other.

View Article and Find Full Text PDF

Despite recent progress in the identification of mediators of podocyte injury, mechanisms underlying podocyte loss remain poorly understood, and cell-specific therapy is lacking. We previously reported that kidney and brain expressed protein (KIBRA), encoded by WWC1, promotes podocyte injury in vitro through activation of the Hippo signaling pathway. KIBRA expression is increased in the glomeruli of patients with focal segmental glomerulosclerosis, and KIBRA depletion in vivo is protective against acute podocyte injury.

View Article and Find Full Text PDF

Very short duration of dual antiplatelet therapy (DAPT) following percutaneous coronary intervention (PCI) has recently attracted a lot of attention with the introduction of newer generations stents. This is appealing, especially in patients at high bleeding risk. However, none of the trials were powered for the individual ischemic and bleeding endpoints.

View Article and Find Full Text PDF

Background: There is a paucity of real-world data assessing the association of operator volumes and mortality specific to primary percutaneous coronary intervention (PPCI).

Methods: Demographic, clinical and outcome data for all patients undergoing PPCI in Leeds General Infirmary, UK, between 1 January 2009 and 31 December 2011, and 1 January 2013 and 31 December 2013, were obtained prospectively. Operator volumes were analysed according to annual operator PPCI volume (low volume: 1-54 PPCI per year; intermediate volume: 55-109 PPCI per year; high volume: ≥110 PPCI per year).

View Article and Find Full Text PDF

Importance: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical aortic valve replacement and is the treatment of choice for patients at high operative risk. The role of TAVI in patients at lower risk is unclear.

Objective: To determine whether TAVI is noninferior to surgery in patients at moderately increased operative risk.

View Article and Find Full Text PDF

Objectives: To assess the impact of balloon use for predilation, valve implantation, or postdilation on in-hospital mortality among patients undergoing transcatheter aortic valve replacement (TAVR).

Background: TAVR utilizes self-expanding, mechanically expanding, or balloon-expandable valves. Balloon inflation is inherent to deployment of balloon-expandable valves.

View Article and Find Full Text PDF

Background: The index of microcirculatory resistance (IMR) of the infarct-related artery and left ventricular end-diastolic pressure (LVEDP) are acute, prognostic biomarkers in patients undergoing primary percutaneous coronary intervention. The clinical significance of IMR and LVEDP in combination is unknown.

Methods: IMR and LVEDP were prospectively measured in a prespecified substudy of the T-TIME clinical trial (Trial of Low Dose Adjunctive Alteplase During Primary PCI).

View Article and Find Full Text PDF

Aims: We compared strategies in the treatment of decompensated severe aortic stenosis. The hypothesis was that undertaking urgent or emergency transcatheter aortic valve implantation (TAVI) directly in such patients is safer and more effective than urgent or emergency balloon aortic valvuloplasty (BAV) followed by elective TAVI or surgical aortic valve replacement (SAVR).

Methods: This was a single-centre retrospective study including all consecutive patients who underwent urgent or emergency BAV or TAVI for decompensated severe aortic stenosis between September 2014 and February 2018.

View Article and Find Full Text PDF

We describe a patient who presented with heart failure 7 years post-transcatheter aortic valve implantation (TAVI) as a result of severe structural valve degeneration. Anatomic challenges, combined with the type of transcatheter heart valve used initially, meant that TAVI-in-TAVI risked obstructing the coronary arteries, even if preceded by bioprosthetic aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction. The patient was treated with balloon aortic valvuloplasty.

View Article and Find Full Text PDF

Objectives: The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves.

Background: The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation.

Methods: Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland.

View Article and Find Full Text PDF

Use of angiography for the assessment of coronary lesions is limited by its inability to provide information regarding the functional significance of stenoses. A number of studies have demonstrated the presence of ischaemia to be the most important determinant of the benefit associated with coronary revascularisation in stable coronary artery disease. Assessment of intra-coronary physiology can guide percutaneous coronary intervention, and is often used for angiographically borderline stenoses.

View Article and Find Full Text PDF

Objectives: This study sought to evaluate the effects of the Carillon device on mitral regurgitation severity and left ventricular remodeling.

Background: Functional mitral regurgitation (FMR) complicates heart failure with reduced ejection fraction and is associated with a poor prognosis.

Methods: In this blinded, randomized, proof-of-concept, sham-controlled trial, 120 patients receiving optimal heart failure medical therapy were assigned to a coronary sinus-based mitral annular reduction approach for FMR or sham.

View Article and Find Full Text PDF

Background: There is a paucity of real-world outcome data comparing clopidogrel, prasugrel and ticagrelor in primary percutaneous coronary intervention (PPCI) for ST-segment elevation myocardial infarction (STEMI). We sought to assess the association of choice of oral P2Y12-receptor inhibitor with clinical outcomes following PPCI for STEMI in a large consecutive patient series.

Methods: Demographic, procedural and 12-month outcome data were prospectively collected for all patients undergoing PPCI in Leeds, UK, between 01 January 2009 and 31 December 2011, and 01 January 2013 and 31 December 2013.

View Article and Find Full Text PDF

Access site vascular complications remain relatively frequent following trans-femoral (TF) transcatheter aortic valve implantation (TAVI), and are associated with significant morbidity as well as increased mortality. Suture-based vascular closure devices (VCD) are widely used and have been demonstrated to reduce the rate of vascular complications. However, failure to achieve adequate hemostasis following their use occurs in some cases, and may necessitate surgical escalation.

View Article and Find Full Text PDF

Background: Very little is known about long-term valve durability after transcatheter aortic valve replacement (TAVR).

Objectives: This study sought to evaluate the incidence of structural valve degeneration (SVD) 5 to 10 years post-procedure.

Methods: Demographic, procedural, and in-hospital outcome data on patients who underwent TAVR from 2007 to 2011 were obtained from the U.

View Article and Find Full Text PDF

Objective: To compare the incidence of silent cerebral infarction and impact on cognitive function following transcatheter aortic valve implantation (TAVI) with the first-generation CoreValve (Medtronic, Minneapolis, Minnesota, USA) and second-generation Lotus valve (Boston Scientific, Natick Massachusetts, USA).

Design: A prospective observational study comprising a 1.5 T cerebral MRI scan, performed preoperatively and immediately following TAVI, and neurocognitive assessments performed at baseline, 30 days and 1 year follow-up.

View Article and Find Full Text PDF

Importance: Microvascular obstruction commonly affects patients with acute ST-segment elevation myocardial infarction (STEMI) and is associated with adverse outcomes.

Objective: To determine whether a therapeutic strategy involving low-dose intracoronary fibrinolytic therapy with alteplase infused early after coronary reperfusion will reduce microvascular obstruction.

Design, Setting, And Participants: Between March 17, 2016, and December 21, 2017, 440 patients presenting at 11 hospitals in the United Kingdom within 6 hours of STEMI due to a proximal-mid-vessel occlusion of a major coronary artery were randomized in a 1:1:1 dose-ranging trial design.

View Article and Find Full Text PDF

Subclavian artery stenosis (SAS) resulting in coronary subclavian steal syndrome (CSSS) is a common but under recognized pathology following coronary artery bypass surgery (CABG). Patients with SAS may be asymptomatic due to the sub-clinical diversion of blood flow from the myocardium and retrograde blood flow during catheter angiography in the left internal mammary artery (LIMA) may be the first suggestion of CSSS. The management of SAS, causing CSSS, may rarely require acute assessment and intervention.

View Article and Find Full Text PDF

Objectives: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves.

Background: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus.

Methods: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland.

View Article and Find Full Text PDF