Objectives: To evaluate the outcome of patients with cranial (C) and extra-cranial (EC) oligometastases treated with stereotactic radiosurgery (SRS)/stereotactic body radiotherapy (SBRT) and standard of care systemic therapy.
Methods: During the period 2018-2022, patients who received SBRT or SRS for oligometastases (≤5 lesions) in addition to systemic therapy were evaluated. PET-CT was done to categorize them as C or EC oligometastases.
Introduction: The Real-time Position Management™ (RPM) is used as a motion management tool to reduce normal tissue complication. However, no commercial software is available to quantify the "beam-on" errors in RPM-generated breathing traces. This study aimed to develop and validate an in-house-coded MATLAB program to quantify the "beam-on" errors in the breathing trace.
View Article and Find Full Text PDFObjective: The aim of this retrospective study is to reduce the dose of heart, both lung and opposite breast and left anterior descending artery (LAD) and avoid long term complication and radiation induced secondary malignancies in radiotherapy left breast/chest wall without losing homogeneity and conformity of the Planning Target Volume (PTV), contoured using Radiotherapy Oncology Group (RTOG 1005) guideline.
Materials And Methods: The treatment plans were generated retrospectively by TFIF, VMAT and Composite techniques for 30 patients. Dose-Volume Histograms (DVHs) were evaluated for PTV and organs at risk (OAR's) and analyzed in two groups BCS and MRM using Wilcoxon signed rank test.
Background: To evaluate 'Rapid Arc (RA)' technique for delivering fractionated stereotactic radiosurgery (FSRS) in patients with recurrent high grade gliomas (HGGs) for minimizing the dose to previously radiated high dose brain volume.
Materials And Methods: Between April 2010 and February 2011, 16 consecutive patients with recurrent HGGs and previously treated with intensity modulated radiation therapy (IMRT) and Temozolamide received FSRS. The median time between IMRT and FSRS was 10.
Australas Phys Eng Sci Med
September 2012
The performance of an image registration (IR) software was evaluated for automatically detecting known errors simulated through the movement of ExactCouch using an onboard imager. Twenty-seven set-up errors (11 translations, 10 rotations, 6 translation and rotation) were simulated by introducing offset up to ± 15 mm in three principal axes and 0° to ± 1° in yaw. For every simulated error, orthogonal kV radiograph and cone beam CT were acquired in half-fan (CBCT_HF) and full-fan (CBCT_FF) mode.
View Article and Find Full Text PDFPhysical and dosimetric characteristics of HDMLC were studied for SRS6, 6, and 10 MV X-rays from Novalis Tx. This in-built tertiary collimator consists of 60 pairs (32 × 0.25 cm; 26 × 0.
View Article and Find Full Text PDFPortal dosimetry (PD) was performed for 181 fields from 14 IMRT plans of various clinical sites at gantry zero and source-to-detector distance (SDD) of 100 cm. PD was realized using aSi1000 electronic portal imaging device (EPID) and portal dose prediction (PDP) algorithm implemented in Eclipse treatment planning system (TPS). Agreement of PDP predicted and EPID measured photon fluence/dose distribution were evaluated using gamma (γ) index set at 3% at 3 mm distance to point agreement (DTA).
View Article and Find Full Text PDF