Publications by authors named "Malcolm McEwen"

High-finesse microcavities offer a platform for compact, high-precision sensing by employing high-reflectivity, low-loss mirrors to create effective optical path lengths that are orders of magnitude larger than the device geometry. Here, we investigate the radiation hardness of Fabry-Pérot microcavities formed from dielectric mirrors deposited on the tips of optical fibers. The microcavities are irradiated under both conventional (∼ 0.

View Article and Find Full Text PDF

Background: The newly available ZAP-X stereotactic radiosurgical system is designed for the treatment of intracranial lesions, with several unique features that include a self-shielding, gyroscopic gantry, wheel collimation, non-orthogonal kV imaging, short source-axis distance, and low-energy megavoltage beam. Systematic characterization of its radiation as well as other properties is imperative to ensure its safe and effective clinical application.

Purpose: To accurately determine the radiation output of the ZAP-X with a special focus on the smaller diameter cones and an aim to provide useful recommendations on quantification of small field dosimetry.

View Article and Find Full Text PDF

Background: Electron synchrotrons produce x-ray beams with dose rates orders of magnitude greater than conventional x-ray tubes and with beam sizes on the order of a few millimeters. These characteristics put severe challenges on current dosimeters to accurately realize absorbed dose or air kerma.

Purpose: This work seeks to investigate the suitability of a novel aluminum-based calorimeter to determine absorbed dose to water with an uncertainty significantly smaller than currently possible with conventional detectors.

View Article and Find Full Text PDF

Purpose: In 2021, the Canadian Organization of Medical Physicists (COMP) conducted its first equity, diversity, and inclusion Climate Survey. The membership's experiences of inclusion, belonging, professional opportunities, discrimination, microaggressions, racism, and harassment in their professional lives are presented.

Methods And Materials: The ethics-reviewed survey was distributed in English and French to full members of COMP.

View Article and Find Full Text PDF

. While the accuracy of dose calculations in water with Acuros XB is well established, experimental validation of dose in bone is limited. Acuros XB reports both dose-to-medium and dose-to-water, and these values differ in bone, but there are no reports of measurements of validation in bone.

View Article and Find Full Text PDF

Clonogenic assays are the gold standard for measuring cell clonogenic survival and enable quantification of a cell line's radiosensitivity through the calculation of the surviving fraction, the ratio of cell clusters (colonies) formed after radiation exposure compared to the number formed without exposure. Such studies regularly utilize Cs-137 irradiators. While uncertainties for specific procedural aspects have been described previously, a comprehensive review has not been completed.

View Article and Find Full Text PDF

UHDpulse - Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates is a recently started European Joint Research Project with the aim to develop and improve dosimetry standards for FLASH radiotherapy, very high energy electron (VHEE) radiotherapy and laser-driven medical accelerators. This paper gives a short overview about the current state of developments of radiotherapy with FLASH electrons and protons, very high energy electrons as well as laser-driven particles and the related challenges in dosimetry due to the ultra-high dose rate during the short radiation pulses. We summarize the objectives and plans of the UHDpulse project and present the 16 participating partners.

View Article and Find Full Text PDF

Purpose: ICRU Report 90 on Key Data for Ionizing-Radiation Dosimetry: Measurement Standards and Applications (2014) has reaffirmed the recommended value of the mean energy required to create an ion pair in air, W , to be 33.97(12) eV. The report also indicates that this "constant" of radiation dosimetry is energy independent above 10 keV, since there is no theoretical or experimental evidence to the contrary.

View Article and Find Full Text PDF

Purpose: To investigate the use of cylindrical chambers for electron beam dosimetry independent of energy by studying the variability of relative ion chamber perturbation corrections, one of the main concerns for electron beam dosimetry with cylindrical chambers.

Methods: Measurements are made with sets of cylindrical and plane-parallel reference-class chambers as a function of depth in water in 8 MeV and 18 MeV electron beams. The ratio of chamber readings for similar chambers is normalized in a high-energy electron beam and can be thought of as relative perturbation corrections.

View Article and Find Full Text PDF

Purpose: To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on long-term stability, (b) water calorimetry measurements to determine absorbed dose to water in high-energy beams for direct calibration of ion chambers, and (c) using measurements of chamber response relative to reference ion chambers, determination of beam quality conversion factors, k , for several ion chamber types.

Methods: Measurements are made in electron beams with energies between 8 MeV and 22 MeV from the NRC Elekta Precise clinical linear accelerator.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to experimentally examine the reliability of the gradient chamber alignment point (gCAP) determination method for accurately identifying water surface location with a range of ionization chambers (ICs).

Materials And Methods: Twelve cylindrical ICs were scanned from depth through a water surface into air using a customized high-accuracy scanning system which allows for accurate alignment of the IC with respect to the true water surface. Thirteen other cylindrical ICs and five parallel-plate ICs were scanned using a standard commercially available scanning system.

View Article and Find Full Text PDF

Purpose: International dosimetry protocols require measurements made with a vented ionization chamber to be corrected for the influence of air density by using the standard temperature-pressure correction factor. The effect of humidity, on the other hand, is generally ignored with the provision that the relative humidity (RH) is within certain limits (typically 20% to 80%). However, there is little experimental data in the published literature as to the true effect of humidity on modern reference-class ionization chambers.

View Article and Find Full Text PDF

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy.

View Article and Find Full Text PDF

Purpose: In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types.

Methods: A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations.

View Article and Find Full Text PDF

The aim of this project was to develop an absorbed dose to water primary standard for Ir-192 brachytherapy based on the Fricke dosimeter. To achieve this within the framework of the existing TG-43 protocol, a determination of the absorbed dose to water at the reference position, D(r0,θ0), was undertaken. Prior to this investigation, the radiation chemical yield of the ferric ions (G-value) at the Ir-192 equivalent photon energy (0.

View Article and Find Full Text PDF

An addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water in megavoltage photon beams is presented. This addendum continues the procedure laid out in TG-51 but new kQ data for photon beams, based on Monte Carlo simulations, are presented and recommendations are given to improve the accuracy and consistency of the protocol's implementation. The components of the uncertainty budget in determining absorbed dose to water at the reference point are introduced and the magnitude of each component discussed.

View Article and Find Full Text PDF

Purpose: This work presents the experimental extraction of the perturbation factor in megavoltage electron beams for three models of silicon diodes (IBA Dosimetry, EFD and SFD, and the PTW 60012 unshielded) using a plastic scintillation detector (PSD).

Methods: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6-, 12-, and 18-MeV clinical electron beams. They also measured depth-dose curves using the IBA Dosimetry, EFD and SFD, and the PTW 60012 unshielded diodes.

View Article and Find Full Text PDF

Purpose: This work presents the experimental extraction of the overall perturbation factor PQ in megavoltage electron beams for NACP-02 and Roos parallel-plate ionization chambers using a plastic scintillation detector (PSD).

Methods: The authors used a single scanning PSD mounted on a high-precision scanning tank to measure depth-dose curves in 6, 12, and 18 MeV clinical electron beams. The authors also measured depth-dose curves using the NACP-02 and PTW Roos chambers.

View Article and Find Full Text PDF

Purpose: Absorbed dose beam quality conversion factors (k(Q) factors) were obtained for 27 different types of ionization chamber. The aim was to obtain objective evidence on the performance of a wide range of chambers currently available, and potentially used for reference dosimetry, and to investigate the accuracy of the k(Q) calculation algorithm used in the TG-51 protocol.

Methods: Measurements were made using the 60Co irradiator and Elekta Precise linac facilities at the National Research Council of Canada.

View Article and Find Full Text PDF

Purpose: Verify experimentally the theoretical prediction of F. Tessier and I. Kawrakow [Med.

View Article and Find Full Text PDF

Purpose: The purposes of this study are to improve the accuracy of source and geometry parameters used in the simulation of large electron fields from a clinical linear accelerator and to evaluate improvement in the accuracy of the calculated dose distributions.

Methods: The monitor chamber and scattering foils of a clinical machine not in clinical service were removed for direct measurement of component geometry. Dose distributions were measured at various stages of reassembly, reducing the number of geometry variables in the simulation.

View Article and Find Full Text PDF