Atrial fibrillation (AF) is the most common sustained arrhythmia and carries an increased risk of stroke and heart failure. Here we investigated how the immune infiltrate of human epicardial adipose tissue (EAT), which directly overlies the myocardium, contributes to AF. Flow cytometry analysis revealed an enrichment of tissue-resident memory T (T) cells in patients with AF.
View Article and Find Full Text PDFBackground: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology.
Methods: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection.
Background: To date, there are no randomized, double-blinded clinical trials comparing catheter ablation to DC cardioversion (DCCV) with medical therapy in patients with persistent atrial fibrillation (PersAF). Conducting a large-scale trial to address this question presents considerable challenges, including recruitment, blinding, and implementation. We conducted a pilot study to evaluate the feasibility of conducting a definitive placebo-controlled trial.
View Article and Find Full Text PDFBackground: Mechanisms sustaining persistent atrial fibrillation (AF) remain unclear.
Objectives: The study sought to evaluate both the clinical outcomes and response to ablation of potential drivers in patients with recurrent persistent AF recurrence following pulmonary vein isolation (PVI).
Methods: A total of 100 patients with persistent AF of <2 years' duration underwent cryoballoon PVI (ECGI phenotyping of persistent AF based on driver burden and distribution to predict response to pulmonary vein isolation).
Background: There is a paucity of data comparing vitamin K antagonists (VKAs) to direct oral anticoagulants (DOACs) at the time of cardiac implantable electronic device (CIED) surgery. Furthermore, the best management of DOACs (interruption vs continuation) is yet to be determined.
Objectives: This study aimed to compare the incidence of device-related bleeds and thrombotic events based on anticoagulant type (DOAC vs VKA) and regimen (interrupted vs uninterrupted).
Aims: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
September 2023
Background: Hypoxia-ischemia predisposes to atrial arrhythmia. Atrial ATP-sensitive potassium channel (K) modulation during hypoxia has not been explored. We investigated the effects of hypoxia on atrial electrophysiology in mice with global deletion of K pore-forming subunits.
View Article and Find Full Text PDFIntroduction: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI).
Methods: Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF.
Introduction: The Heliostar™ ablation system is a novel RF balloon ablation technology with an integrated three-dimensional mapping system. Here, we describe our early experience and procedural outcomes using this technology for atrial fibrillation catheter ablation.
Methods: We sought to comprehensively assess the first 60 consecutive patients undergoing pulmonary vein isolation using the novel HELISOTAR™ RF balloon technology including procedural outcomes.
Introduction: Markers predicting atrial fibrillation (AF) termination and freedom from AF/atrial tachycardia (AT) has been proposed. This study aimed to evaluate the role of novel coronary sinus (CS) electrogram characteristics in predicting the acute ablation response and freedom from AF/AT during follow-up.
Methods: Patients undergoing ablation for persistent AF as part of the Stochastic Trajectory Analysis of Ranked signals mapping study were included.
Aim: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon.
Methods And Results: This prospective multi-centre study included patients that underwent cryoablation for AF.
Aims: Cardiac tamponade is a high morbidity complication of transseptal puncture (TSP). We examined the associations of TSP-related cardiac tamponade (TRCT) for all patients undergoing left atrial ablation at our center from 2016 to 2020.
Methods And Results: Patient and procedural variables were extracted retrospectively.
Objectives: Diagnosing atrial fibrillation (AF) in patients following Cryptogenic stroke (CS) has therapeutic implications that can reduce the risk of further strokes. However, it's indolent and paroxysmal nature makes this challenging. Prolonged rhythm monitoring using implantable loop recorders (ILRs) can significantly increase the AF detection rate in the clinical trial paradigm.
View Article and Find Full Text PDFObjectives: The purpose of this study was to assess the performance and limitations of low-voltage zones (LVZ) localization by optimized late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) scar imaging in patients with cardiac implantable electronic devices (CIEDs).
Background: Scar evaluation by LGE-CMR can assist ventricular tachycardia (VT) ablation, but challenges with electroanatomical maps coregistration and presence of imaging artefacts from CIED limit accuracy.
Methods: A total of 10 patients underwent VT ablation and preprocedural LGE-CMR using wideband imaging.
Background: The risk factors for developing pacing induced left ventricular dysfunction (LVD) in patients with high burden of right ventricular pacing (RVP) is poorly understood. Therefore, in the present study, we aimed to assess the determinants of pacing induced LVD.
Methods: Our data were retrospectively collected from 146 patients with RVP > 40% who underwent generator change (GC) or cardiac resynchronization therapy (CRT) upgrade between 2016 and 2019 who had left ventricular ejection fraction (EF) ≥50% at initial implant.
J Cardiovasc Electrophysiol
March 2022
Introduction: Ethanol ablation (EA) is an alternative option for subjects with ventricular arrhythmias (VAs) refractory to conventional medical and ablative treatment. However, data on the efficacy and safety of EA remain sparse.
Methods: A systematic literature search was conducted.
Aim: Implantable loop recorders (ILRs) are now routinely implanted for long-term cardiac monitoring in the clinical setting. The aim of this study was to examine the real-world performance of these devices focusing on the management changes made in response to ILR-recorded data.
Methods And Results: This was a single-centre, prospective observational study of consecutive patients undergoing ILR implantation.
Eur Heart J Qual Care Clin Outcomes
September 2021
BACKGROUNDEpicardial adipose tissue (EAT) directly overlies the myocardium, with changes in its morphology and volume associated with myriad cardiovascular and metabolic diseases. However, EAT's immune structure and cellular characterization remain incompletely described. We aimed to define the immune phenotype of EAT in humans and compare such profiles across lean, obese, and diabetic patients.
View Article and Find Full Text PDFAims: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). Data on the efficacy of catheter ablation of AF in HCM patients are sparse.
Methods And Results: Observational multicentre study in 137 HCM patients (mean age 55.
IEEE J Sel Top Quantum Electron
January 2021
Small form-factor sensors are widely used in minimally invasive intravascular diagnostic procedures. Manufacturing complexities associated with miniaturizing current fiber-optic probes, particularly for multi-parameter sensing, severely constrain their adoption outside of niche fields. It is especially challenging to rapidly prototype and iterate upon sensor designs to optimize performance for medical devices.
View Article and Find Full Text PDF: Most biomedical research has focused on sampling COVID-19 patients presenting to hospital with advanced disease, with less focus on the asymptomatic or paucisymptomatic. We established a bioresource with serial sampling of health care workers (HCWs) designed to obtain samples before and during mainly mild disease, with follow-up sampling to evaluate the quality and duration of immune memory. : We conducted a prospective study on HCWs from three hospital sites in London, initially at a single centre (recruited just prior to first peak community transmission in London), but then extended to multiple sites 3 weeks later (recruitment still ongoing, target n=1,000).
View Article and Find Full Text PDF