Suture-mediated closure device and Figure-of-Eight suture are commonly used to achieve hemostasis after use of large bore venous access. Although both methods of closure are commonly used in clinical practice, a head-to-head comparison in a controlled setting has not been performed. Patients presenting to a single center for elective left atrial appendage occlusion or transcatheter edge-to-edge mitral valve repair were randomized to large bore venous closure using the Perclose ProGlide suture-based closure or a Figure-of-Eight suture closure.
View Article and Find Full Text PDFJ Vector Borne Dis
November 2023
Background & Objectives: Malaria is the most common parasitic infection in children and the most common cause of mortality by vector-borne disease in tropical countries. In these endemic countries there is limited published literature on the clinical profile and severity of Plasmodium vivax malaria in children. We highlight the clinical presentations and severity of malaria in children belonging to Uttar Pradesh, North India Methods: This observational study was conducted in a tertiary care hospital, in Moradabad, western Uttar Pradesh, India.
View Article and Find Full Text PDFBackground: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies.
Objectives: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis.
Methods: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected.
Background: Left atrial appendage (LAA) occlusion is an alternative therapy to oral anticoagulants to reduce stroke risk in patients with nonvalvular atrial fibrillation (NVAF). The Amulet IDE trial compared the Amplatzer™ Amulet™ occluder (Abbott) with the Watchman™ 2.5 device (Boston Scientific) for LAA occlusion in patients with NVAF.
View Article and Find Full Text PDFBackground: Low ejection fraction (EF) and low flow as determined by an echocardiographic stroke volume index (SVi) <35 mL/m are associated with low transvalvular gradients and increased mortality in both severe aortic stenosis (AS) and post-transcatheter aortic valve replacement (TAVR). Absence of an elevated echocardiographic transaortic gradient post-TAVR is considered a marker of procedural success despite the absence of data on its impact on mortality.
Objectives: The authors sought to examine the association of invasive and echocardiographic gradients post-TAVR with all-cause mortality in relation to flow and EF.
Background: Transesophageal echocardiogram (TEE) is the preferred imaging modality to guide transcatheter left atrial appendage closure (LAAC). Intracardiac echocardiography (ICE) has evolved as a less invasive alternative to TEE. Several observational studies have shown similar success rates and perioperative complications between TEE and ICE for LAAC.
View Article and Find Full Text PDFBackground: Post-operative atrial fibrillation (POAF) is common after aortic valve replacement (AVR) and is associated with worse outcomes. We performed a meta-analysis of randomized controlled trials comparing Surgical Aortic Valve Replacement (SAVR) and Transcatheter Aortic Valve Replacement (TAVR) for incidence of POAF at 30 days.
Methods: We searched databases from 1/1/1990 to 1/1/2020 for randomized studies comparing TAVR and SAVR.
We present a rare case of iatrogenic pneumopericardium, pneumoperitoneum, and pericarditis after emergency pericardiocentesis for pericardial tamponade. The patient had profound bowel distention at the time of the procedure that led to iatrogenic pericardioperitoneal fistula formation along with transverse colon perforation, which manifested later after pericardial drain removal. This condition required repeat pericardiocentesis, laparoscopic colon repair, a long course of antibiotics, and an eventual pericardial window.
View Article and Find Full Text PDFJ Invasive Cardiol
December 2021
MitraClip is approved for treatment of both degenerative and functional mitral regurgitation (MR). The landmark trials for this device included only patients with A2P2 location of MR. Initial commercial experience showed A2P2 location was associated with higher technical success as compared with non-A2P2 location.
View Article and Find Full Text PDFBackground: Percutaneous closure of the left atrial appendage (LAA) is an alternative to chronic oral anticoagulation to reduce stroke risk in patients with nonvalvular atrial fibrillation. The Amulet IDE trial (Amplatzer Amulet Left Atrial Appendage Occluder IDE Trial) was designed to evaluate the safety and effectiveness of the dual-seal mechanism of the Amulet LAA occluder compared with the Watchman device.
Methods: Patients with nonvalvular atrial fibrillation at increased risk of stroke were randomly assigned (1:1) to undergo percutaneous implantation of a LAA occluder with the Amulet occluder or Watchman device.
Despite more than 80% of interventional operators reporting one or more orthopedic injuries attributed to the X-ray laboratory, there has been limited adoption of various strategies and equipment to minimize these injuries. A comprehensive review of these methods to reduce musculoskeletal strain is lacking in the current literature, and is essential in order to ensure a long, healthy, and productive interventional career.
View Article and Find Full Text PDFWe describe a patient with recurrent embolic strokes who was found to have a persistent left superior vena cava draining into a pulmonary vein. Transcatheter placement of a vascular plug resulted in successful occlusion of the superior vena cava. Repeat bubble study on follow-up imaging was negative for a right-to-left shunt.
View Article and Find Full Text PDFBackground: In India, huge mortality occurs due to cardiovascular diseases (CVDs) as these diseases are not diagnosed in early stages. Machine learning (ML) algorithms can be used to build efficient and economical prediction system for early diagnosis of CVDs in India.
Methods: A total of 1670 anonymized medical records were collected from a tertiary hospital in South India.
The authors describe a patient with hypertrophic cardiomyopathy with concomitant left ventricular outflow tract obstruction and aortic stenosis. Detailed haemodynamic assessment of the serial lesions was performed. Alcohol septal ablation resulted in a significant reduction of gradients across the left ventricular outflow tract.
View Article and Find Full Text PDFBackground: The modes of failure of coronary polymer-jacketed guidewires have received limited study.
Methods: We queried the Manufacturer and User Facility Device Experience (MAUDE) database between January 2011 and December 2020 for reports on coronary polymer-jacketed guidewires and retrieved 254 reports.
Results: The most common failure mode was failure of the guidewire to cross (36.
Catheter Cardiovasc Interv
November 2021
Background: There is a paucity of literature on safety and efficacy of various transseptal puncture (TSP) needles.
Objectives: To assess the reported mechanisms of failure, complications, and outcomes among the most frequently used transseptal needles in the United States.
Methods: We queried the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database between January 2011 and January 2021 for reports on the most commonly used transseptal needles: NRG (Baylis Medical, Montreal, Canada), and BRK (St.
Catheter Cardiovasc Interv
February 2022
Background: There is limited data on complications associated with the use of coronary embolic protection devices (EPDs).
Methods: We queried the Manufacturer and User Facility Device Experience database between November 2010 and November 2020 for reports on coronary EPDs: Spider FX (Medtronic, Minneapolis, MN) and Filterwire EZ (Boston Scientific, Natick, MA).
Results: We retrieved 119 reports on coronary EPD failure (Spider FX n = 33 and Filterwire EZ n = 86), most of which (78.
The cardiovascular and renal systems share an intimate physiological relationship, wherein a perturbance in one system may have an adverse effect on the other. Since the burden of renal disease increases with age, there is a considerable interest in the pathophysiology of kidney disease in the geriatric patient population. This review will explore the physiological dynamics behind the increased susceptibility to kidney disease in this population.
View Article and Find Full Text PDFBackground: Transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) is an increasingly prevalent treatment in patients who are intermediate or high risk for surgical intervention. In nonagenarian patients undergoing TAVR, symptomatic relief and quality of life (QoL) outcomes have not been well established. This study explores these outcomes in this patient population that has been underrepresented in landmark clinical trials.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
August 2021
Objective: To evaluate the impact of COVID-19 pandemic migitation measures on of ST-elevation myocardial infarction (STEMI) care.
Background: We previously reported a 38% decline in cardiac catheterization activations during the early phase of the COVID-19 pandemic mitigation measures. This study extends our early observations using a larger sample of STEMI programs representative of different US regions with the inclusion of more contemporary data.