Noise exposure is a distinct hazard during hand-held concrete grinding activities, and its assessment is challenging because of the many variables involved. Noise dosimeters were used to examine the extent of personal noise exposure while concrete grinding was performed with a variety of grinder sizes, types, accessories, and available dust control methods. Noise monitoring was conducted in an enclosed area covering 52 task-specific grinding sessions lasting from 6 to 72 minutes.
View Article and Find Full Text PDFConcrete grinding exposes workers to unacceptable levels of crystalline silica dust, known to cause diseases such as silicosis and possibly lung cancer. This study examined the influence of major factors of exposure and effectiveness of existing dust control methods by simulating field concrete grinding in an enclosed workplace laboratory. Air was monitored during 201 concrete grinding sessions while using a variety of grinders, accessories, and existing dust control methods, including general ventilation (GV), local exhaust ventilation (LEV), and wet grinding.
View Article and Find Full Text PDFJ Occup Environ Hyg
October 2007
The effectiveness of wet grinding (wet dust reduction method) and ventilated grinding (local exhaust ventilation method, LEV) in reducing the levels of respirable crystalline silica dust (quartz) and respirable suspended particulate matter (RSP) were compared with that of uncontrolled (no dust reduction method) conventional grinding. A field laboratory was set up to simulate concrete surface grinding using hand-held angle grinders in an enclosed workplace. A total of 34 personal samples (16 pairs side-by-side and 2 singles) and 5 background air samples were collected during 18 concrete grinding sessions ranging from 15-93 min.
View Article and Find Full Text PDFStudies of the indoor air quality of restaurants have rarely focused on ventilation system performance in relation to air pollutants and climatic factors. This study was conducted in eight restaurants to examine this issue by determining the ventilation flow rates and the levels of carbon dioxide (CO2), ambient temperature, and relative humidity during at least one complete shift of serving a meal. The mean values of number of dining patrons, ventilation flow rates, and the levels of CO2, ambient temperature, and relative humidity were not significantly different in the nonsmoking dining rooms and the smoking dining rooms.
View Article and Find Full Text PDF