Publications by authors named "Magnus Bath"

Purpose: We aim to investigate the localization, visibility, and measurement of lung nodules in digital chest tomosynthesis (DTS).

Approach: Computed tomography (CT), maximum intensity projections (CT-MIP) (transaxial versus coronal orientation), and computer-aided detection (CAD) were used as location reference, and inter- and intra-observer agreement regarding lung nodule size was assessed. Five radiologists analyzed DTS and CT images from 24 participants with lung , focusing on lung nodule localization, visibility, and measurement on DTS.

View Article and Find Full Text PDF

Purpose: Chest tomosynthesis (CTS) has a relatively longer acquisition time compared with chest X-ray, which may increase the risk of motion artifacts in the reconstructed images. Motion artifacts induced by breathing motion adversely impact the image quality. This study aims to reduce these artifacts by excluding projection images identified with breathing motion prior to the reconstruction of section images and to assess if motion compensation improves overall image quality.

View Article and Find Full Text PDF

The As Low As Reasonably Achievable (ALARA) principle includes taking into account economic and societal factors. To consider these factors, decision-aiding techniques such as cost-benefit analysis were introduced by the International Commission on Radiological Protection (ICRP) 50 y ago. Over the years, developments in health economics have led to new ways of deriving the concept of a value of a statistical life (VSL), which now is influencing the monetary value assigned to a unit of collective dose for radiological protection purposes (the α value) used in cost-benefit analyses.

View Article and Find Full Text PDF

Wearing lead aprons and thyroid collars for long periods of time has a subjective component: to balance the effective dose reduction with the effort of carrying a heavy load. Occupational radiation exposure has decreased dramatically in the last century within the health care system. During the same period the use of lead aprons and thyroid collars has also gone up.

View Article and Find Full Text PDF

Objective: There are several studies that show high defect rates of transducers in clinical use. The purpose of the present study was to investigate whether image quality and the risk for misdiagnosis is affected by using defective transducers.

Methods: Four defective transducers with varying degrees of defect severity, still in clinical use, were selected.

View Article and Find Full Text PDF

Purpose: We developed a method to visualize the image distortion induced by nonlinear noise reduction algorithms in computed tomography (CT) systems.

Approach: Nonlinear distortion was defined as the induced residual when testing a reconstruction algorithm by the criteria for a linear system. Two types of images were developed: a nonlinear distortion of an object () image and a nonlinear distortion of noise () image to visualize the nonlinear distortion induced by an algorithm.

View Article and Find Full Text PDF

Purpose: The aim of our study was to compare the image quality assessments of vascular anatomy between interventional radiographers and interventional radiologists using digital subtraction angiography (DSA) runs acquired during an interventional radiology procedure.

Approach: Visual grading characteristics (VGC) analysis was used to assess image quality by comparing two groups of images, where one group consisted of procedures in which radiation dose was optimized (group A, ) and one group where dose optimization was not performed (group B, ). The radiation dose parameters were optimized based on theoretical and empirical evidence to achieve radiation dose reductions during uterine artery embolization procedures.

View Article and Find Full Text PDF

This study sought to achieve radiation dose reductions for patients receiving uterine artery embolisation (UAE) by evaluating radiation dose measurements for the preceding generation (Allura) and upgraded (Azurion) angiography system. Previous UAE regression models in the literature could not be applied to this centre's practice due to being based on different angiography systems and radiation dose predictor variables. The aims of this study were to establish whether radiation dose is reduced with the upgraded angiography system and to develop a regression model to determine predictors of radiation dose specific to the upgraded angiography system.

View Article and Find Full Text PDF

The purpose of this study was to introduce a continuous quality improvement (CQI) program for radiation dose optimisation during uterine artery embolisation (UAE) and assess its impact on dose reduction and image quality. The CQI program investigated the effects of optimising radiation dose parameters on the kerma-area product (KAP) and image quality when comparing a 'CQI intervention' group (n = 50) and 'Control' group (n = 50). Visual grading characteristics (VGC) analysis was used to assess image quality, using the 'Control' group as a reference.

View Article and Find Full Text PDF

The aim of the present study was to demonstrate cases of cost-benefit analysis within healthcare, of how economic factors can be considered in occupational radiological protection, in agreement with the as low as reasonably achievable principle and present Swedish legislations. In the first part of the present study, a comparison of examples within health economics used by authorities and institutes in Sweden was made. The comparison focused on value of a statistical life, quality-adjusted life year, and monetary cost assigned to a unit of collective dose for radiation protection purposes (α-value).

View Article and Find Full Text PDF

Purpose: To develop a method to perform quality control (QC) of X-ray tubes and automatic exposure control (AEC) as a part of the QC of the radiographic and fluoroscopic X-ray system. Our aim is to verify the output from the X-ray tube by comparing the measured radiation output, or air kerma, to the theoretical output given the applied exposure settings and geometry, in addition to comparing the measured kV to the nominal kV. The AEC system for fluoroscopic and conventional X-ray systems is assessed by determining the absorbed dose to a homogenous phantom with different thicknesses.

View Article and Find Full Text PDF

Imaging optimisation can benefit from combining structured data with qualitative data in the form of audio and video recordings. Since video is complex to work with, there is a need to find a workable solution that minimises the additional time investment. The purpose of the paper is to outline a general workflow that can begin to address this issue.

View Article and Find Full Text PDF

Denoising reconstruction techniques can introduce nonlinear properties into computed tomography (CT) systems. These nonlinear algorithms introduce distortion which affects the assessment of the resolution of the system. The purpose of the present study was to decouple and investigate amplitude modulation and waveform distortion in reconstruction algorithms in CT.

View Article and Find Full Text PDF

Purpose: To evaluate two chest tomosynthesis (CTS) scoring systems for cystic fibrosis (CF), one system developed by Vult von Steyern et al. (VvS) and one system based on the Brody scoring system for high-resolution computed tomography (HRCT) (modified Brody (mB)). Brody scoring of HRCT was used as reference.

View Article and Find Full Text PDF

The purpose of the present work was to evaluate the use of resampling statistical methods for analysis of visual grading data-implemented in the software VGC Analyzer-by comparing the reanalyzed results from previously performed visual grading studies with the results calculated by gold standard receiver operating characteristic (ROC) methodology, Obuchowski-Rockette (OR)-Dorfman-Berbaum-Metz (DBM) multiple-readers and multiple-case (MRMC) and by analysis of simulated visual grading data where the true distribution was presumed to be known. The reanalysis was performed on two multiple-reader studies with non-paired data and paired data, respectively. The simulation study was performed by simulating a large number of visual grading characteristics (VGC) studies and by analyzing the statistical distribution of null hypothesis (H0) rejection rate.

View Article and Find Full Text PDF

In contrast to optical colonoscopy, computed tomography colonography (CTC) has the ability to reveal pathology outside of the colon. While identification of colorectal lesions at CTC requires only limited radiation dose, the detection of abnormalities in extracolonic soft tissue requires more radiation. The purpose of this study was to investigate the influence of ultra-low-dose (ULD) CTC on the detection and characterisation of extracolonic findings.

View Article and Find Full Text PDF

Purpose: The high incidence of defective ultrasound transducers in clinical practice has been shown in several studies. Recently, a novel method using only stored images for automatic detection of defective transducers was presented. The method makes it possible to remotely monitor many transducers at the same time and send a notification when a defective transducer is found.

View Article and Find Full Text PDF

ViewDEX (Viewer for Digital Evaluation of X-ray Images) is an image viewer compatible with Digital Imaging and Communications in Medicine (DICOM) that has been especially designed to facilitate image perception and observer performance studies within medical imaging. The software was first released in 2004 and since then a continuous development has been ongoing. One of the major drawbacks of previous versions of ViewDEX has been that they have lacked functionality enabling the possibility to evaluate multiple images and/or image stacks simultaneously.

View Article and Find Full Text PDF

Purpose: This study attempted to develop a method to measure the applied recursive filtration and to determine the noise reduction of four different fluoroscopic systems. The study also attempted to elucidate the importance of considering the recursive filter for quality control tests concerning signal-to-noise ratio (SNR) or image quality. The vendor's settings for recursive filtration factor (β) are, unfortunately, often not available.

View Article and Find Full Text PDF

Rationale And Objectives: To evaluate the effect of reduction in effective dose on the reproduction of anatomical structures in chest tomosynthesis (CTS).

Materials And Methods: Twenty-four CTS examinations acquired at exposure settings resulting in an effective dose of 0.12 mSv for an average sized patient were included in the study.

View Article and Find Full Text PDF
Article Synopsis
  • Digital tomosynthesis (DTS) may serve as a low-cost, low-dose alternative to computed tomography (CT) for monitoring incidental solid pulmonary nodules.
  • A study involving 106 participants compared DTS and CT for measuring solid nodules; findings showed significant variability in size measurements and volume changes between the two methods.
  • The study concluded that measurement variability limits the reliability of DTS in detecting size changes in small solid nodules compared to CT.
View Article and Find Full Text PDF

Purpose: A contrast-detail phantom such as CDRAD is frequently used for quality assurance, optimization of image quality, and several other purposes. However, it is often used without considering the uncertainty of the results. The aim of this study was to assess two figure of merits (FOM) originating from CDRAD regarding the variations of the FOMs by dose utilized to create the x-ray image.

View Article and Find Full Text PDF

The objective of the present study was to study the effect of adaptive image processing (GOP processing) on the visibility of anatomical structures in direct digital panoramic images. The study comprised panoramic images of 50 consecutive adult individuals aged 18-60 years. Nine dentists working with dental radiology compared the structural image quality of all standard-processed and GOP-processed panoramic images for six anatomical structures, using a six-point scale for visual grading characteristics analysis.

View Article and Find Full Text PDF

Objective: The objective of the present study was to study the effect of adaptive image processing on the visibility of anatomical structures in storage phosphor plate (SPP) panoramic images.

Materials And Methods: Three hundred SPP panoramic X-ray radiographs of children and adolescents were used. The radiographs were post-processed using general operator processor (GOP) technology, resulting in both a standard-processed and a GOP-processed radiograph.

View Article and Find Full Text PDF