J Interv Card Electrophysiol
August 2020
Background: Warfarin is deemed safe compared to bridging with heparin in the peri-procedure setting while implanting cardiac devices. The timing of discontinuation and re-initiation of direct anticoagulant agents (DOACs) such as dabigatran, apixaban, and rivaroxaban in the peri-procedural setting in comparison to warfarin is not well studied.
Objective: We wanted to compare three DOAC agents with warfarin during cardiac device implantation.
J Interv Card Electrophysiol
April 2017
Purpose: In patients who undergo implantable cardiac defibrillator (ICD) implantation for primary prevention of sudden cardiac death (SCD), data is unclear whether their ICD generator needs to be replaced at end of life if their left ventricular ejection fraction (EF) improves. Despite improvement in EF, the underlying scar may represent a potential substrate for ventricular arrhythmias.
Methods: Data on 280 patients who underwent ICD implantation for primary prevention of SCD was obtained from two centers.
J Interv Card Electrophysiol
August 2014
Background: Pre- and postablation atrial fibrillation (AF) brain natriuretic peptide (BNP) levels were shown to predict increased recurrence of AF following ablation.
Objective: Our objective was to assess whether elevated BNP levels merely represent the presence of AF at the time of measurement or indeed the true recurrence of AF.
Methods And Results: In a prospective study of 88 patients undergoing AF ablation, BNP levels were measured immediately before, after, 24 h, and 4-6 months postablation.