Publications by authors named "Maciej Budzanowski"

Laboratory of Individual and Environmental Dosimetry (LADIS) at the Institute of Nuclear Physics is the largest dosimetry service in Poland. Extremity ring dosimetry measurements are performed at LADIS laboratory for ˃20 years, with accredited procedure since 2002. According to the quality system based on PN-EN ISO/IEC 17025:2018-02 standard, Hp(0.

View Article and Find Full Text PDF

Background: In interventional radiology the highest radiation doses are usually recorded for both the medical staff and the patients. Interventional procedures with X-rays are implemented in a number of medical specializations. This paper concerns the exposure of interventional teams performing orthopedic procedures under X-rays control.

View Article and Find Full Text PDF

Background: Extended control of staff exposure in interventional radiology has been legally required over the last few years. This is determined by a number of factors, including the type of procedure, technical conditions and methodology. In orthopedic procedures fluoroscopy is used to control surgical reconstructions.

View Article and Find Full Text PDF

Stringent standards of hygiene must be applied in medical institutions, especially at operating blocks or during interventional radiology procedures. Medical equipment, including personal dosemeters that have to be worn by medical staff during such procedures, needs therefore to be sterilised. In this study, the effect of various sterilisation procedures has been tested on the dose response of extremity rings and of eye lens dosemeters in which thermoluminescent (TL) detectors (of types MTS-N and MCP-N, respectively) are used.

View Article and Find Full Text PDF

Individual dosimetry service based on thermoluminescence (TLD) detectors has started its activity at the Institute of Nuclear Physics (IFJ) in Krakow in 1965. In 2002, the new Laboratory of Individual and Environment Dosimetry (Polish acronym LADIS) was established and underwent the accreditation according to the EN-PN-ISO/IEC 17025 standard. Nowadays, the service is based on the worldwide known standard thermoluminescent detectors MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P), developed at IFJ, processed in automatic thermoluminescent DOSACUS or RE2000 (Rados Oy, Finland) readers.

View Article and Find Full Text PDF

Lithium fluoride thermoluminescence (TL) detectors, with different Li composition (Li-6 and Li-7) and various activators (LiF:Mg,Ti, LiF:Mg,Cu,P), are widely used for dosimetry in space. The primary radiation field in space is composed of fast electrons, protons and heavy charged particles (HCP). By its interaction with the structures of the spacecraft, this field may be modified inside the crew cabin.

View Article and Find Full Text PDF