Publications by authors named "Maarten van Wiechen"

Background: Trials comparing non-vitamin K oral anticoagulant (NOAC) versus antiplatelet-based strategies have shown a reduction of subclinical leaflet thrombosis at the cost of increased mortality and major-bleedings. NOACs were often combined with antiplatelet therapy.

Aims: The Rotterdam Edoxaban (REDOX) study aimed to evaluate the impact of edoxaban monotherapy on the incidence of hypo-attenuated leaflet thickening (HALT) and reduced leaflet motion (RLM) and to evaluate safety in terms of mortality, thromboembolic events and major bleeding.

View Article and Find Full Text PDF

New conduction disorders remain a frequent complication in current transcatheter aortic valve replacement (TAVR) era. Left bundle branch block (LBBB) occurs early in about 20-30 % of TAVR-patients, persists at 1 month in about 35-45 % of cases and will likely remain thereafter. Third-degree atrioventricular block (AV3B) affects approximately 15 % of patients.

View Article and Find Full Text PDF

Background: Large-bore arteriotomies can be percutaneously closed with suture-based or plug-based vascular closure device (VCD) strategies. The efficacy of both techniques remains controversial.

Aims: We conducted a meta-analysis of comparative studies between both VCD strategies, focusing on the most commonly applied VCDs (MANTA and ProGlide).

View Article and Find Full Text PDF

Background: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome.

Objectives: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV.

View Article and Find Full Text PDF

Background: Multislice computed tomography (MSCT) may reveal hypo-attenuated leaflet thickening (HALT) and/or reduced leaflet motion (RELM) in approximately 15 % of patients after transcatheter aortic valve replacement (TAVR). These supposedly thrombogenic phenomena may be associated with neurological events and increased transprosthetic gradients. It is unclear whether oral anticoagulant therapy -specifically a factor Xa inhibitor- could affect the incidence of HALT/RELM.

View Article and Find Full Text PDF

Objectives: To study the safety and feasibility of a restrictive temporary-RV-pacemaker use and to evaluate the need for temporary pacemaker insertion for failed left ventricular (LV) pacing ability (no ventricular capture) or occurrence of high-degree AV-blocks mandating continuous pacing.

Background: Ventricular pacing remains an essential part of contemporary transcatheter aortic valve implantation (TAVI). A temporary-right-ventricle (RV)-pacemaker lead is the standard approach for transient pacing during TAVI but requires central venous access.

View Article and Find Full Text PDF

Selecting patients with a high chance of endured benefit from transcatheter aortic valve implantation (TAVI) is becoming relevant with changing indications and increasing number of TAVI being performed. The aim of our study was to investigate the association of the multidimensional prognostic index (MPI) based on a comprehensive geriatric assessment (CGA) on survival. The TAVI Care & Cure program is a prospective, observational registry of patients referred for TAVI at the Erasmus MC University Medical Center.

View Article and Find Full Text PDF

Aims: To elucidate the frequency and clinical impact of left atrial appendage thrombus (LAAT) in patients set for transcatheter aortic valve implantation (TAVI).

Methods And Results: All patients undergoing TAVI between January 2014 and June 2020 with analysable multislice computed tomography (MSCT) for LAAT were included. Baseline and procedural characteristics were collected, pre-procedural MSCT's were retrospectively analysed for LAAT presence.

View Article and Find Full Text PDF

Importance: Transcatheter aortic valve replacement (TAVR) failure is often managed by an urgent implantation of a supplementary valve during the procedure (2-valve TAVR [2V-TAVR]). Little is known about the factors associated with or sequelae of 2V-TAVR.

Objective: To examine the incidence, causes, and outcomes of 2V-TAVR.

View Article and Find Full Text PDF

This article provides supplementary tables and figures to the research article: Frequency, Impact and Predictors of Access Complications with Plug-Based Large-Bore Arteriotomy Closure - A patient level meta-analysis [1]. The data provide insight in the type and management of access complications related to the plug-based MANTA vascular closure device (VCD) for large-bore catheter-based cardiovascular interventions. Since MANTA is mostly used in transcatheter aortic valve replacement (TAVR) procedures, this article also contains a sub-group analysis on TAVR procedures using contemporary valve-platforms.

View Article and Find Full Text PDF

Background The need for new permanent pacemaker implantation (PPI) after Transcatheter Aortic Valve Implantation (TAVI) remains a critical issue. Membranous Septum (MS) length is associated with PPI after TAVI. The aim of this study was to identify different MS thresholds for the contemporary THV-platforms.

View Article and Find Full Text PDF

Background/purpose: The MANTA is a dedicated plug-based large-bore vascular closure device (VCD) providing safe hemostasis in most patients, but data on the clinical impact and mechanisms of MANTA related complications are limited. This study sought to determine the frequency, impact and predictors of MANTA-related access complications.

Methods/materials: This patient-level meta-analysis included data from 2 medical device approval studies and 1 post-approval registry.

View Article and Find Full Text PDF

Introduction: We aimed to compare conduction dynamics and need for permanent pacemaker implantation (PPI) after CoreValve, Evolut R and PRO (transcatheter aortic valve replacement (TAVR)).

Methods: Patients were stratified based on conduction at baseline; Cohort A had normal conduction, Cohort B had conduction abnormalities including atrioventricular (AV)-block, fascicular block or complete bundle branch block. Three different dynamic QRS-patterns were defined: stable QRS-duration, transient QRS-prolongation and persistent QRS-prolongation.

View Article and Find Full Text PDF

Background: The MANTA vascular closure device (VCD) is dedicated to large bore access closure and associated with favorable results in selected study populations. Anatomical predictors for access site complications are lacking.

Aim: To evaluate MANTA in a real-world population and identify predictors for vascular complications.

View Article and Find Full Text PDF
Article Synopsis
  • Surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) are both treatments for aortic stenosis, and this study aimed to compare TAVR performed on failed transcatheter valves (TAV-in-TAV) versus surgical valves (TAV-in-SAV).
  • Data from 434 TAV-in-TAV and 624 TAV-in-SAV procedures were analyzed after matching 330 patients from both groups, focusing on procedural success, safety, and 30-day and 1-year mortality rates.
  • Results showed that TAV-in-TAV had higher procedural success rates (72.7% vs. 62.4%) and better aortic valve area and
View Article and Find Full Text PDF

Objectives: This study sought to test the superiority in terms of efficacy and safety of a dedicated plug-based vascular closure device (VCD) during transcatheter aortic valve replacement (TAVR) over a suture-based VCD.

Background: Vascular complications after TAVR are relevant and often associated with VCD failure.

Methods: The MASH (MANTA vs.

View Article and Find Full Text PDF

Background: The axillary artery is an alternative route for patients with comorbidities and unfavorable femoral arteries who need transcatheter aortic valve replacement (TAVR). Simplified trans-axillary transcatheter aortic valve replacement (TAx-TAVR) implies a completely percutaneous approach under local anesthesia and arteriotomy closure with vascular closure techniques. Herein, we report on early experience with simplified TAx-TAVR under local anesthesia.

View Article and Find Full Text PDF

Aims: The aim of this study was to investigate the total amount, size and heterogeneity of debris captured among different transcatheter valve types and while repositioning.

Methods And Results: A total of 328 patients who underwent transcatheter aortic valve implantation (TAVI) with the SENTINEL cerebral embolic protection (CEP) at our centre were eligible. Histopathological and semiquantitative analysis of captured debris was performed and data were entered into our prospective database.

View Article and Find Full Text PDF

Background: The optimal antithrombotic therapy after transcatheter aortic valve implantation (TAVI) is unsettled. Short and longer-term thromboembolic and bleeding risk post TAVI remain high. Non-vitamin K oral anticoagulant drugs (NOAC) may be attractive after TAVI but the implications of prolonged NOAC in this setting require further research.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) brings symptom relief and improvement in health-related quality of life (HRQoL) in the majority of patients treated for symptomatic, severe aortic stenosis. However, there is a substantial group of patients that do not benefit from TAVI. The aim of this study is to investigate the impact of frailty on HRQoL 1 year after TAVI.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail.

Objectives: The authors sought to examine outcomes following redo-TAVR.

View Article and Find Full Text PDF

Background: In aortic stenosis, valvulo-arterial impedance (Zva) estimates the overall left ventricular afterload (valve and arterial component). We investigated the association of Zva (≥5 versus <5 mm Hg mL m) on quality of life (QOL) and exercise performance (EP) ≥1 year after transcatheter aortic valve replacement (TAVR).

Methods: The study population consists of 250 TAVR patients in whom baseline Zva and follow-up QOL was prospectively assessed using EuroQOL-5-dimensions instruments; EP was assessed in 192 patients who survived ≥1 year after TAVR using questionnaires related to daily activities.

View Article and Find Full Text PDF

Contemporary state of the art percutaneous coronary intervention techniques offer treatment strategies and solutions to an increasing number of patients with heart failure and complex coronary artery disease. Percutaneous mechanical circulatory support is intended to alleviate the mechanical and energetic workload imposed to a failing ventricle by reducing left ventricle pressures and volumes and potentially also increasing coronary blood flow. The PulseCath iVAC2L is a transaortic left ventricular assist device that applies a pneumatic driving system to produce pulsatile forward flow.

View Article and Find Full Text PDF