Minimally invasive access cavities have been proposed in the last decade to reduce tooth tissue loss during endodontic treatment and mitigate compromised fracture resistance of endodontically treated teeth. Fracture resistance of molars with different types of access cavity design may be affected by restorative materials and aging. Insufficient literature data exist on the effect of cavity design and type of restorative materials on restorative aspects such as material adaptation or photo-polymerization in restricted access cavities.
View Article and Find Full Text PDFObjectives: To evaluate the effects of enhanced personal protective equipment (Enhanced_PPE) on student-operator's experience and restorative procedure.
Methods: Student-operators (N = 29 Year 3 dental students) performed Class II composite restorations (SimpliShade, Kerr) in typodont upper molars (OneDental) equipped with N95 respirators, full-face shields, disposable headwear and gowns (Enhanced_PPE) or surgical masks, protective glasses/goggles and non-disposable gowns (Standard_PPE) 2 weeks later. Cavity dimensions were measured on cone beam computed tomography images.
Objective: To measure degree of conversion (DC) of a flowable composite, microtensile bond strength (MTBS) to dentine in the snow-plow technique with/without preheating and temperature in the preheated composite.
Materials And Methods: For DC, snow-plow specimens of Filtek Ultimate Flowable (Flow) and Filtek Bulk Fill (Bulk) (3M) were prepared by light-curing composites simultaneously in standardized molds while in control groups light-curing was separate. DC of Flow was measured using micro-Raman spectroscopy.
Objectives: To answer the PICO(S) question: Is there a difference in clinical longevity between direct and indirect resin composite restorations placed on permanent posterior teeth?
Data: Randomized controlled clinical trials (RCTs) investigating direct and indirect resin composite restorations in posterior permanent teeth were considered.
Sources: Several electronic databases were searched, with no language or date restrictions. The revised Cochrane Collaboration's tool for assessing risk of bias (RoB-2) was used to analyze the studies; meta-analyses were run and the certainty of evidence was assessed by the GRADE tool.
This study aimed to (1) comparatively analyze properties of Sr- and Mg-substituted hydroxyapatite (HAP)-based dental inserts; (2) evaluate insert bonding to restorative materials, and (3) evaluate the effect of doped HAP inserts on fracture resistance (FR) of human molars with large occlusal restorations. By ion-doping with Sr or Mg, 3 insert types were obtained and characterized using XRD, SEM, Vickers hardness and fracture toughness. Shear bond strength (SBS) was determined between acid etched or unetched inserts and following materials: Maxcem cement (Kerr); Filtek Z250 (3M) bonded with Single Bond Universal (SBU; 3M) or Clearfil Universal (Cf; Kuraray).
View Article and Find Full Text PDFHigh elution and diffusion of 2-hydroxylethyl methacrylate (HEMA) and camphorquinone (CQ) through dentinal tubules may induce pulp injury and postoperative sensitivity. We aimed to investigate the melatonin protective effect in HEMA- and CQ-treated human dental pulp cells (hDPCs) as well as its relevance in a mechanism for postoperative sensitivity in diabetic patients. hDPCs were exposed to HEMA (5 mM) and/or CQ (1 mM) in the absence and presence of melatonin (MEL) (0.
View Article and Find Full Text PDFThe antioxidant activity and chemical stability of 6-amino-6-deoxy-L-ascorbic acid (D1) and -methyl-6-amino-6-deoxy-L-ascorbic acid (D2) were examined with ABTS and DPPH assays and compared with the reference L-ascorbic acid (AA). In addition, the optimal storing conditions, as well as the pH at which the amino derivatives maintain stability, were determined using mass spectrometry. Comparable antioxidant activities were observed for NH-bioisosteres and AA.
View Article and Find Full Text PDFMitochondrial neurogastrointestinal encephalomyopathy (MNGIE) is a rare disorder commonly diagnosed in later disease stages when it prominently manifests as malnutrition. We report on a female patient diagnosed with MNGIE at the age of 36. She was severely malnourished due to loss of resorptive surface after several surgical procedures, gastrointestinal dysmotility, and small intestinal bacterial overgrowth.
View Article and Find Full Text PDFArticle Title And Bibliographic Information: Bonding of Glass-Ionomer Cement and Adhesives to Silver Diamine Fluoride-treated Dentin: An Updated Systematic Review and Meta-Analysis. Fröhlich TT, Botton G, Rocha RO. J Adhes Dent.
View Article and Find Full Text PDFObjectives: To evaluate CIEDE2000/CIELAB differences in color (ΔE/ΔE), and translucency parameter (ΔTP/ΔTP), and gloss of gingiva-colored resin-based restorative materials upon staining/aging.
Materials And Methods: Disc-shaped, 10 mm in diameter, and 2-mm-thick samples (n = 5/group) were made from giomer (Beautifil II gingiva), oligomer-based (crea.lign GUM gel), CAD/CAM polymethyl-methacrylate-based (IvoBase CAD), PMMA-based (ProBase Hot), and dimethacrylate-based (SR Nexco Paste Gingiva).
This study investigated differences in colour (ΔE) and translucency parameter (ΔTP) of nanofilled/microhybrid composites and a glass-ionomer cement following immersion in bioflavonoid (Citrox)- or chlorhexidine-based mouth rinses. Sixty disc-shaped specimens (N = 5/group) of Filtek Supreme (3M), Gradia Anterior (GC) and Fuji IX (GC) were exposed to Citrox/0.2%CHX (Perio+0.
View Article and Find Full Text PDFObjectives: This retrospective study evaluated the factors influencing the clinical failure of noncarious cervical lesion (NCCL) restorations.
Methods: Patients were routinely treated by undergraduate or postgraduate students and randomly received a clinical recall evaluation. A retrospective study was performed with two experienced calibrated examiners to evaluate NCCL restorations, including the critical parameters of retention, caries, marginal discoloration, and marginal integrity.
Background: The outbreak of COVID-19 pandemic in 2020 has dramatically changed teaching approach in dental schools due to the switch to distance learning and the lack of practice training in direct contact with patients with possible impact on clinical skills of students. The aim of the study was to assess the level of the 2020 final year dental students' self-confidence in performing different dental procedures through specially designed questionnaire and compare it to self-confidence of the 2019 final year students.
Materials And Methods: An anonymous questionnaire consisting of 40 questions regarding self-confidence level in performing 40 different dental procedures and based on five points Likert-like scale was distributed during November 2020 to final year dental students whose studies were disrupted by the COVID-19 pandemic lockdown in one semester.
The objective of this work was to measure and correlate the degree of conversion (DC), mechanical properties and monomer elution from self-, dual- and light-cured core composites. Five samples of each of the following materials were prepared for each test: Clearfil (Core, Photo Core, Automix), Bisco (Core-Flo, Light-Core and Bis-Core). DC was determined using FTIR, compressive and flexural strength and modulus of elasticity using a universal testing machine and microhardness using Vickers hardness.
View Article and Find Full Text PDFObjectives: This systematic review and meta-analysis evaluated the effects of non-thermal atmospheric plasma (NTAP) treatment on dentin wetting and adhesive-dentin bond strength.
Data/sources: This report followed the PRISMA 2020 statement. Two reviewers conducted literature search of MEDLINE, Web of Science and Scopus databases up to the end of November 2020.
The aim of this study was to compare color changes, surface roughness and gloss of a microhybrid and nanohybrid composite whitened in a simulated in-office or at-home procedure using 40% hydrogen peroxide or 16% carbamide peroxide, respectively. CIELab coordinates were measured before, during and after treatment using VITA EasyShade V (VITA) and ∆E calculated. Surface roughness was measured using a surface roughness tester (SJ210; Mitutoyo).
View Article and Find Full Text PDFHereditary angioedema (HAE) attacks are caused by excessive activation of the contact system. Understanding how the contact system is activated in HAE, especially in patients with normal C1 inhibitor (HAEnCI), is essential to effectively treat this disease. Contact system activation involves the cleavage of several proteins including Factor XII (FXII), high molecular weight kininogen (HK), prekallikrein, sgp120 (ITIH4) and C1 inhibitor (C1-INH) before the subsequent generation of bradykinin that mediates HAE.
View Article and Find Full Text PDFThe majority of the drugs which target membrane-embedded protease γ-secretase show an unusual biphasic activation-inhibition dose-response in cells, model animals, and humans. Semagacestat and avagacestat are two biphasic drugs that can facilitate cognitive decline in patients with Alzheimer's disease. Initial mechanistic studies showed that the biphasic drugs, and pathogenic mutations, can produce the same type of changes in γ-secretase activity.
View Article and Find Full Text PDFObjective: To analyze the effects of factors 'composite,' 'medium,' and 'time' on color, translucency, and sorption/solubility of sculptable universal composites for enamel layering upon immersion in colored beverages.
Materials And Methods: Disk-shaped specimens, 10 mm in diameter and 2 mm thick (n = 5/group), of ultrafine, hybrid composite Essentia (GC), microhybrid Gaenial Anterior (GC), nanofilled Filtek Ultimate Enamel and Body ( 3M ESPE) were immersed in red wine, coffee, or distilled water for 15 days. CIELab color coordinates were measured and CIEDE2000 (∆E ) and Translucency Parameter differences (∆TP ) were calculated.
Introduction: Open pores between endodontic sealer and root canal walls present potential niches for bacterial growth and migration pathways. The aim was to assess the internal and external porosity of calcium silicate-based sealers and to ascertain the long-term effect of storage in simulated body fluid on sealer porosity.
Methods: Sixteen single-rooted teeth were filled with gutta-percha and 1 of 4 root canal sealers: BioRoot RCS, EndoSequence BC, MTA Fillapex, or AH Plus.