Bottom-up growth offers precise control over the structure and geometry of semiconductor nanowires (NWs), enabling a wide range of possible shapes and seamless heterostructures for applications in nanophotonics and electronics. The most common vapor-liquid-solid (VLS) growth method features a complex interaction between the liquid metal catalyst droplet and the anisotropic structure of the crystalline NW, and the growth is mainly orchestrated by the triple-phase line (TPL). Despite the intrinsic mismatch between the droplet and the NW symmetries, its discussion has been largely avoided because of its complexity, which has led to the situation when multiple observed phenomena such as NW axial asymmetry or the oscillating truncation at the TPL still lack detailed explanation.
View Article and Find Full Text PDFGrounded in communication models of cultural competence, this study reports on the development and testing of the first module in a larger virtual reality (VR) implicit bias training for physicians to help them better: (a) recognize implicit bias and its effects on communication, patients, and patient care; (b) identify their own implicit biases and exercise strategies for managing them; and (c) learn and practice communicating with BIPOC patients in a culture-centered manner that demonstrates respect and builds trust. Led by communication faculty, a large, interdisciplinary team of researchers, clinicians, and engineers developed the first module tested herein focused on training goal (a). Within the module, participants observe five scenes between patient Marilyn Hayes (a Black woman) and Dr.
View Article and Find Full Text PDFEarly-life social experiences shape adult phenotype, yet the underlying behavioral mechanisms remain poorly understood. We manipulated early-life social experience in the highly social African cichlid fish Astatotilapia burtoni to investigate the effects on behavior and stress axis function in juveniles. Juveniles experienced different numbers of social partners in stable pairs (1 partner), stable groups (6 fish; 5 partners), and socialized pairs (a novel fish was exchanged every 5 days; 5 partners).
View Article and Find Full Text PDFObjective: Alcohol-related liver disease (ALD) is the most common cause of liver-related ill health and liver-related deaths in the UK, and deaths from ALD have doubled in the last decade. The management of ALD requires treatment of both liver disease and alcohol use; this necessitates effective and constructive multidisciplinary working. To support this, we have developed quality standard recommendations for the management of ALD, based on evidence and consensus expert opinion, with the aim of improving patient care.
View Article and Find Full Text PDFThe growth of transition-metal dichalcogenides (TMDCs) has been performed so far using most established thin-film growth techniques (e.g., vapor phase transport, chemical vapor deposition, molecular beam epitaxy, etc.
View Article and Find Full Text PDFWe report silicon nanowire (SiNW) growth with a novel Cu-In bimetallic catalyst using a plasma-enhanced chemical vapor deposition (PECVD) method. We study the structure of the catalyst nanoparticles (NPs) throughout a two-step process that includes a hydrogen plasma pre-treatment at 200 °C and the SiNW growth itself in a hydrogen-silane plasma at 420 °C. We show that the H-plasma induces a coalescence of the Cu-rich cores of as-deposited thermally evaporated NPs that does not occur when the same annealing is applied without plasma.
View Article and Find Full Text PDFPurpose: The Controlled Attenuation Parameter (CAP score) is based on ultrasonic properties of retropropagated radiofrequency signals acquired by Fibroscan (Echosens, Paris, France). Since ultrasound propagation is influenced by the presence of fat, CAP score was developed to quantify steatosis. The aim of this study was to delineate the accuracy of CAP in diagnosing hepatic steatosis, compared to the gold standard of liver biopsy.
View Article and Find Full Text PDFParallel nanomaterials possess unique properties and show potential applications in industry. Whereas, vertically aligned 2D nanomaterials have plane orientations that are generally chaotic. Simultaneous control of their growth direction and spatial orientation for parallel nanosheets remains a big challenge.
View Article and Find Full Text PDFA comparison was made between the image quality of a photon-counting CT (PCCT) and a dual-source CT (DSCT). The evaluation of image quality was performed using a Catphan CT phantom, and the physical metrics, such as the noise power spectrum and task transfer function, were measured for both PCCT and DSCT at three CT dose indices (1, 5 and 10 mGy). Polyenergetic and virtual monoenergetic reconstructions were used to evaluate the performance differences by simulating a Gaussian spot with a radius of 5 mm and calculating the detectability index.
View Article and Find Full Text PDFBackground: Medical devices in the United States can be FDA approved either by the premarket notification (510(k)) or premarket approval process (PMA). Applications for PMA are more intensive than 510(k). This study aims to compare the recall rates of 510(k) and PMA General and Plastic Surgery (Surgery) devices and to educate physicians about potential flaws in the approval process.
View Article and Find Full Text PDFLancet Gastroenterol Hepatol
March 2023
Sample preparation on cryo-EM grids can give various results, from very thin ice and homogeneous particle distribution (ideal case) to unwanted behavior such as particles around the "holes" or complexes that do not entirely correspond to the one in solution (real life). We recently run into such a case and finally found out that variations in the 3D reconstructions were systematically correlated with the grid batches that were used. We report the use of several techniques to investigate the grids' characteristics, namely TEM, SEM, Auger spectroscopy and Infrared Interferometry.
View Article and Find Full Text PDFWe used in situ transmission electron microscopy (TEM) to observe the dynamic changes of Si nanowires under electron beam irradiation. We found evidence of structural evolutions under TEM observation due to a combination of electron beam and thermal effects. Two types of heating holders were used: a carbon membrane, and a silicon nitride membrane.
View Article and Find Full Text PDFThis study was aimed to examine the clinical utility and impact of the 2016 Banff criteria for acute antibody-mediated rejection (acute AMR) in patients with liver transplantation. Among adult patients with donor-specific antibody (DSA) assays performed between 2015 and 2020, cases with proved DSA (mean fluorescent index >2000) and matched liver biopsy available were reviewed. Among 55 patients identified, 28 (51%) had class I DSA, 45 (82%) had class II DSA and 18 (33%) had both.
View Article and Find Full Text PDFBackground: The Baveno VI consensus identifies patients with compensated advanced chronic liver disease (cACLD) who can safely avoid screening endoscopy. However, concordance in clinical practice with this guidance is unknown. We audited clinical practice and the provision of transient elastography (TE) aiming to identify potential cost savings and benefits.
View Article and Find Full Text PDFIn and Sn are the type of catalysts which do not introduce deep level electrical defects within the bandgap of germanium (Ge). However, Ge nanowires produced using these catalysts usually have a large diameter, a tapered morphology, and mixed crystalline and amorphous phases. In this study, we show that plasma-assisted vapor-liquid-solid (PA-VLS) method can be used to synthesize Ge nanowires.
View Article and Find Full Text PDFLiver transplant is a life-saving treatment with 1-year and 5-year survival rates of 90% and 70%, respectively. However, organ demand continues to exceed supply, such that many patients will die waiting for an available organ. This article reviews for the general gastroenterologist the latest developments in the field to reduce waiting list mortality and maximise utilisation of available organs.
View Article and Find Full Text PDFWhen Si nanowires (NWs) have diameters below about 10 nm, their band gap increases as their diameter decreases; moreover, it can be direct if the material adopts the metastable diamond hexagonal structure. To prepare such wires, we have developed an original variant of the vapor-liquid-solid process based on the use of a bimetallic Cu-Sn catalyst in a plasma-enhanced chemical vapor deposition reactor, which allows us to prevent droplets from coalescing and favors the growth of a high density of NWs with a narrow diameter distribution. Controlling the deposited thickness of the catalyst materials at the sub-nanometer level allows us to get dense arrays (up to 6 × 10 cm) of very-small-diameter NWs of 6 nm on average (standard deviation of 1.
View Article and Find Full Text PDFActa Crystallogr A Found Adv
September 2021
Quasicrystals have special crystal structures with long-range order, but without translational symmetry. Unexpectedly, carousel-like successive flippings of groups of atoms inside the ∼2 nm decagonal structural subunits of the decagonal quasicrystal AlCrFeSi were directly observed using in situ high-temperature high-resolution transmission electron microscopy imaging. The observed directionally successive phason flips occur mainly clockwise and occasionally anticlockwise.
View Article and Find Full Text PDF