Publications by authors named "M Zapadlo"

In 2022, the International Council for Harmonisation released draft guidelines Q2(R2) and Q14, intending to specify the development and validation activities that should be carried out during the lifespan of an analytical technique addressed to assess the quality of medicinal products. In the present study, these recommendations were implemented in Capillary Electrophoresis method development for the quality control of a drug product containing trimecaine, by applying Analytical Quality by Design. According to the Analytical Target Profile, the procedure should be able to simultaneously quantify trimecaine and its four impurities, with specified analytical performances.

View Article and Find Full Text PDF

Although phototherapy (PT) is a standard treatment for neonatal jaundice, no validated clinical methods for determination of bilirubin phototherapy products are available. Thus, the aim of our study was to establish a such method for clinical use. To achieve this aim, a LC-MS/MS assay for simultaneous determination of Z-lumirubin (LR) and unconjugated bilirubin (UCB) was conducted.

View Article and Find Full Text PDF

A total of 196 out of 209 polychlorobiphenyl (PCB) congeners were resolved using GC×GC-TOFMS with a non-polar/ionic liquid column series consisting of poly(50%-n-octyl-50%-methyl)siloxane and (1,12-di(tripropylphosphonium)dodecane bis(trifluoromethansulfonyl)amide) in the first and second dimension, respectively. It has been found that 13 PCB congeners overlap in five doublets (CB12+CB13, CB62+CB75, CB70+CB76, CB97+CB125 and CB153+CB168) and one triplet (CB90+CB101+CB113). All toxic, "dioxin like" congeners were separated with no interferences from any PCB congener.

View Article and Find Full Text PDF

The orthogonality of three columns coupled in two series was studied for the congener specific comprehensive two-dimensional GC separation of polychlorinated biphenyls (PCBs). A non-polar capillary column coated with poly(5%-phenyl-95%-methyl)siloxane was used as the first ((1)D) column in both series. A polar capillary column coated with 70% cyanopropyl-polysilphenylene-siloxane or a capillary column coated with the ionic liquid 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethane-sulfonyl)imide were used as the second ((2)D) columns.

View Article and Find Full Text PDF

The non-modulated transfer (NMT) of the total effluent of the separation of polychlorinated biphenyls (PCBs) on two columns coupled in series has been studied. A non-polar poly(5%-phenyl-95%-methyl)siloxane column (40 m x 100 microm x 0.1 microm) and a polar 70%-cyanopropyl-polysilphenylene-siloxane column (4 m x 0.

View Article and Find Full Text PDF