Background: Fanconi syndrome is a disorder of the proximal tubule that leads to malabsorption of various electrolytes and substances and is a common consequence of drug-induced nephrotoxicity. However, cases of dietary supplement-induced Fanconi syndrome are rare, and detailed reports on the evaluation of renal histology in patients with this syndrome are lacking.
Case Presentation: We present two cases of dietary supplement-induced Fanconi syndrome that was confirmed by kidney biopsy.
Phase imaging without a phase wrapping ambiguity is required for wide-axial-range 3D imaging in the fields of surface topography measurement and biomedical imaging. Although multicascade-linked synthetic-wavelength digital holography (MCL-SW-DH) using an optical frequency synthesizer (OFS) is a promising method to meet this requirement, the slow switching of multiple optical wavelengths in the OFS prevents rapid imaging. In the work described in this article, a line-by-line spectral-shaped electro-optics-modulator-based optical frequency comb (EOM-OFC) is used as a light source in MCL-SW-DH to achieve rapid image acquisition.
View Article and Find Full Text PDFWe construct a full-field phase-shifting terahertz digital holography (PS-THz-DH) system by use of a THz quantum cascade laser and an uncooled, 2D micro-bolometer array. The PS-THz-DH enables us to separate the necessary diffraction-order image from unnecessary diffraction-order images without the need for spatial Fourier filtering, leading to suppress the decrease of spatial resolution. 3D shape of a visibly opaque object is visualized with a sub-millimeter lateral resolution and a sub-µm axial resolution.
View Article and Find Full Text PDFWe proposed a refractive index (RI) sensing method with temperature compensation by using an optical frequency comb (OFC) sensing cavity including a multimode-interference (MMI) fiber, namely, the MMI-OFC sensing cavity. The MMI-OFC sensing cavity enables simultaneous measurement of material-dependent RI and sample temperature by decoding from the comb spacing frequency shift and the wavelength shift of the OFC. We realized the simultaneous and continuous measurement of RI-related concentration of a liquid sample and its temperature with precisions of 1.
View Article and Find Full Text PDFDigital holography (DH) is a promising method for non-contact surface topography because the reconstructed phase image can visualize the nanometer unevenness in a sample. However, the axial range of this method is limited to the range of the optical wavelength due to the phase wrapping ambiguity. Although the use of two different wavelengths of light and the resulting synthetic wavelength, i.
View Article and Find Full Text PDF