Publications by authors named "M Tonetto"

Article Synopsis
  • High ventilation relative to carbon dioxide output (V̇/V̇CO) leads to breathing difficulties and exercise limitations in chronic obstructive pulmonary disease (COPD) patients.
  • A study tested the effectiveness of oral sildenafil in improving exercise tolerance and reducing dyspnea in COPD patients, comparing it to a placebo after conducting cardiopulmonary exercise tests.
  • Results showed that sildenafil (both 50 mg and 100 mg doses) did not significantly enhance respiratory function or reduce exertional dyspnea in these patients, indicating it may not be a beneficial treatment option for this condition.
View Article and Find Full Text PDF

Objective: To assess interobserver agreement among radiologists regarding the current Fleischner Society diagnostic criteria for usual interstitial pneumonia (UIP) patterns on computed tomography (CT).

Materials And Methods: Using the Fleischner Society criteria for UIP CT patterns, five raters, working independently, categorized the high-resolution CT (HRCT) scans of 44 patients with interstitial lung disease who underwent lung biopsy. The raters also evaluated the presence, extent, and distribution of the most relevant imaging findings, as well as indicating their level of confidence in the most likely diagnosis and in up to three diagnostic hypotheses.

View Article and Find Full Text PDF

Background: This study aimed to evaluate the bond strength and internal adaptation of customized glass fiber posts using Bulk Fill flowable composite resins (BF) and conventional composite resin.

Material And Methods: Fifty bovine teeth were randomly divided (n=10) according to the following groups: G1 (control): glass fiber posts were adapted to the root canal and luted with Rely-X ARC cement (3M® ESPE); G2: fiber posts smaller than the root canal diameter were customized using Filtek™ Z350 XT (3M® ESPE) conventional composite resin, and luted similarly to Group 1. G3: posts were customized with Tetric N-Ceram Bulk Fill composite resin (Ivoclar Vivadent AG), G4: posts were customized with Filtek™ Bulk Fill Flow (3M® ESPE), and G5: posts were customized with SureFil SDRTM flow (DENTSPLY), respectively.

View Article and Find Full Text PDF

Objective: To evaluate the diagnostic accuracy of the Radiological Society of North America (RSNA) classification system for coronavirus disease 2019 (COVID-19) pneumonia compared to pre-pandemic chest computed tomography (CT) scan images to mitigate the risk of bias regarding the reference standard.

Materials And Methods: This was a retrospective, cross-sectional, diagnostic test accuracy study. Chest CT scans, carried out from May 1 to June 30, 2020, and from May 1 to July 17, 2017, were consecutively selected for the COVID-19 (positive reverse transcription-polymerase chain reaction [RT-PCR] for severe acute respiratory syndrome coronavirus 2 result) and control (pre-pandemic) groups, respectively.

View Article and Find Full Text PDF

Introduction: The purpose of this study was to evaluate the effect of brown and green propolis on bond strength of the fiberglass posts to root canal dentin, and to compare it with conventional endodontic irrigants.

Methods And Materials: Sixty bovine teeth were selected, decoronated and randomly distributed into six groups (=10), according to the irrigation solution: 0.9% saline solution (Control); 2% chlorhexidine (CHX); 5% malic acid (MA); 0.

View Article and Find Full Text PDF