Neurointervention
November 2024
Purpose: The direct aspiration first pass technique (ADAPT) is an effective and safe endovascular treatment for distal medium vessel occlusions (DMVOs). We evaluated technical features and initial results of a novel reperfusion catheter (REDTM 62) used for frontline aspiration thrombectomy of M2 occlusions in acute ischemic stroke patients. Appropriate aspiration catheters are crucial for a successful ADAPT maneuver; however, the selection of catheters suitable for smaller-sized vessels is scarce compared to the ones for large vessel occlusions.
View Article and Find Full Text PDFBackground: Data on impact of COVID-19 vaccination and outcomes of patients with COVID-19 and acute ischemic stroke undergoing mechanical thrombectomy are scarce. Addressing this subject, we report our multicenter experience.
Methods And Results: This was a retrospective analysis of patients with COVID-19 and known vaccination status treated with mechanical thrombectomy for acute ischemic stroke at 20 tertiary care centers between January 2020 and January 2023.
Purpose: We report our initial experience with endovascular embolization of intracranial aneurysms using this new self-expanding open-cell stent system (pEGASUS stent system) with the antithrombogenic hydrophilic polymer coating.
Materials And Methods: We retrospectively reviewed all patients treated with stent-assisted coiling or the Woven EndoBridge device using the pEGASUS stent system between September 2022 and June 2023. Demographic, clinical, and angiographic data were analyzed as well as short-term follow-up, including procedural complication rates and aneurysmal occlusion rates using the Raymond-Roy occlusion classification (RROC).
J Neurol Surg A Cent Eur Neurosurg
July 2024
Treatment of vertebral artery aneurysms can be challenging due to the unusual vascular anatomy or unfeasibility of traditional endovascular techniques. We describe a novel approach for endovascular treatment of a ruptured intracranial vertebral artery aneurysm with bilateral vertebral artery occlusions and hypoplasia of the posterior communicating arteries. Successful coil embolization was performed using a collateral pathway for microcatheterization via anastomosis between the deep cervical artery and the vertebral artery.
View Article and Find Full Text PDFBackground And Purpose: The new p64 flow diverter with hydrophilic polymer coating (HPC) was designed to reduce thrombogenicity. To date, it is unclear how antithrombogenic surface modifications affect neoendothelialization and thrombus formation in patients with unruptured intracranial aneurysms. The purpose of this study was to evaluate the safety and effectiveness of the p64MW-HPC in the treatment of unruptured aneurysms of small to giant size and of both the anterior and posterior circulation.
View Article and Find Full Text PDF