Publications by authors named "M Sapag Hagar"

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Background: This study aimed to determine whether artificial intelligence (AI)-based automated assessment of left atrioventricular coupling index (LACI) can provide incremental value above other traditional risk factors for predicting mortality among patients with severe aortic stenosis (AS) undergoing coronary CT angiography (CCTA) before transcatheter aortic valve replacement (TAVR).

Methods: This retrospective study evaluated patients with severe AS who underwent CCTA examination before TAVR between September 2014 and December 2020. An AI-prototype software fully automatically calculated left atrial and left ventricular end-diastolic volumes and LACI was defined by the ratio between them.

View Article and Find Full Text PDF

: To validate the automated quantification of cardiac chamber volumes and myocardial mass on non-contrast chest CT using cardiac MR (CMR) as a reference. : We retrospectively included 53 consecutive patients who received non-contrast chest CT and CMR within three weeks. A deep learning model created cardiac segmentations on axial soft-tissue reconstructions from CT, covering all four cardiac chambers and the left ventricular myocardium.

View Article and Find Full Text PDF

New formyl indole derivatives based on thiobarbituric acid were designed for targeting parasitological applications. The new compounds (5-((1H-indol-3-yl)methylene)-2-thioxodihydropyrimidine-4,6(1H,5H)-dione (3a), and 5-((1-benzyl-1H-indol-3-yl)methylene)-2-thioxodihydropyrimidine-4,6(1H,5H)-dione (3b) were synthesized as thioxodihydropyrimidine derivatives via aldol condensation reaction. The structures of the synthesized compounds were confirmed based on their spectral data via FT-IR, H and C NMR spectral characterization.

View Article and Find Full Text PDF

Rationale And Objectives: The purpose of this study was to explore intra-individual differences in pericoronary adipose tissue (PCAT) fat attenuation index (FAI) between photon-counting detector (PCD)- and energy-integrating detector (EID)-CT.

Material And Methods: Patients were prospectively enrolled for a PCD-CT research scan within 30 days of EID-CT. Both acquisitions were reconstructed using a Qr36 kernel at 0.

View Article and Find Full Text PDF