Interferon-induced transmembrane protein 3 (IFITM3) is a restriction factor that limits viral pathogenesis and exerts poorly understood immunoregulatory functions. Here, using human and mouse models, we demonstrate that IFITM3 promotes MyD88-dependent, TLR-mediated IL-6 production following exposure to cytomegalovirus (CMV). IFITM3 also restricts IL-6 production in response to influenza and SARS-CoV-2.
View Article and Find Full Text PDFThis article was originally published Online First without open access. After publication it was discovered that the author had ordered open access during the production process. The incorrect license was assigned to this paper due to a technical error.
View Article and Find Full Text PDFThis gamma scintigraphy imaging study was the first to assess pulmonary and extrathoracic deposition and regional lung deposition patterns of a radiolabelled long-acting muscarinic antagonist/long-acting β-agonist fixed-dose combination glycopyrronium/formoterol fumarate dihydrate (GFF) 14.4/10μg (equivalent to glycopyrrolate/formoterol fumarate 18/9.6μg), delivered by pressurized metered dose inhaler (pMDI) using novel co-suspension delivery technology.
View Article and Find Full Text PDFTo ensure consistency of clinical outcomes, orally inhaled therapies must exhibit consistent delivered dose and aerosol properties at the time of manufacturing, throughout storage, and during various patient-use conditions. Achieving consistency across these scenarios has presented a significant challenge, especially for combination products that contain more than one drug. This study characterized the delivered dose and aerosol properties of glycopyrrolate/formoterol fumarate metered dose inhaler (GFF MDI; Bevespi Aerosphere™).
View Article and Find Full Text PDFJ Appl Clin Med Phys
November 2015
The purpose of this study was to show that the nominal peak tube voltage potential (kVp) and measured half-value layer (HVL) can be used to generate energy spectra and fluence profiles for characterizing a computed tomography (CT) X-ray source, and to validate the source model and an in-house kV X-ray dose computation algorithm (kVDoseCalc) for computing machine- and patient-specific CT dose. Spatial variation of the X-ray source spectra of a Philips Brilliance and a GE Optima Big Bore CT scanner were found by measuring the HVL along the direction of the internal bow-tie filter axes. Third-party software, Spektr, and the nominal kVp settings were used to generate the energy spectra.
View Article and Find Full Text PDF