The historical restriction of magnetic resonance imaging (MRI) for patients with cardiac implantable electronic devices (CIEDs) has been lifted by certified MRI-conditional systems in recent years. Mixed-brand CIED systems consisting of a generator from one manufacturer and at least one lead from another manufacturer are not certified for MRI. We evaluated the temporal trend in the prevalence of mixed-brand systems in the era of MRI-conditional systems.

View Article and Find Full Text PDF

Artificial Intelligence (AI) applications and Machine Learning (ML) methods have gained much attention in recent years for their ability to automatically detect patterns in data without being explicitly taught rules. Specific features characterise the ECGs of patients with Brugada Syndrome (BrS); however, there is still ambiguity regarding the correct diagnosis of BrS and its differentiation from other pathologies. This work presents an application of Echo State Networks (ESN) in the Recurrent Neural Networks (RNN) class for diagnosing BrS from the ECG time series.

View Article and Find Full Text PDF

Background: Mitral isthmus (MI) conduction block is a fundamental step in anatomical approach treatment for persistent atrial fibrillation (PeAF). However, MI block is hardly achievable with endocardial ablation only. Retrograde ethanol infusion (EI) into the vein of Marshall (VOM) facilitates MI block.

View Article and Find Full Text PDF

Background: The best ablation treatment for persistent atrial fibrillation (PeAF) patients is still debated. The vein of Marshall (VOM) seems to be a promising target for ablation and could be combined with a linear set of ablation lesions. The aim of our study is to evaluate the incidence of AF recurrences in a PeAF population treated with a comprehensive ablation approach consisting of VOM ethanol infusion (EI), pulmonary vein isolation (PVI), a left atrial (LA) roofline, a mitral line (guided by the newly formed lesion after alcohol infusion into the VOM and validated by pacing), and a cavotricuspid isthmus line.

View Article and Find Full Text PDF

Background: Most recent cardiac implantable electronic devices (CIEDs) can safely undergo a cardiovascular magnetic resonance (CMR) scan under certain conditions, but metal artifacts may degrade image quality. The aim of this study was to assess the overall diagnostic yield of CMR and the extent of metal artifacts in a multicenter, multivendor study on CIED patients referred for CMR.

Methods: We analyzed 309 CMR scans from 292 patients (age 57 ± 16 years, 219 male) with an MR-conditional pacemaker ( = 122), defibrillator (n = 149), or loop recorder (n = 38); CMR scans were performed in 10 centers from 2012 to 2020; MR-unsafe implants were excluded.

View Article and Find Full Text PDF