In this work, a new method to determine and correct the linear drift for any crystalline orientation in a single-column-resolved high-resolution scanning transmission electron microscopy (HR-STEM) image, which is based on angle measurements in the Fourier space, is presented. This proposal supposes a generalization and the improvement of a previous work that needs the presence of two symmetrical planes in the crystalline orientation to be applicable. Now, a mathematical derivation of the drift effect on two families of asymmetric planes in the reciprocal space is inferred.
View Article and Find Full Text PDFFrom simple averaging to more sophisticated registration and restoration strategies, such as super-resolution (SR), there exist different computational techniques that use a series of images of the same object to generate enhanced images where noise and other distortions have been reduced. In this work, we provide qualitative and quantitative measurements of this enhancement for high-angle annular dark-field scanning transmission electron microscopy imaging. These images are compared in two ways, qualitatively through visual inspection in real and reciprocal space, and quantitatively, through the calculation of objective measurements, such as signal-to-noise ratio and atom column roundness.
View Article and Find Full Text PDFDuring image acquisition of crystalline materials by high-resolution scanning transmission electron microscopy, the sample drift could lead to distortions and shears that hinder their quantitative analysis and characterization. In order to measure and correct this effect, several authors have proposed different methodologies making use of series of images. In this work, we introduce a methodology to determine the drift angle via Fourier analysis by using a single image based on the measurements between the angles of the second Fourier harmonics in different quadrants.
View Article and Find Full Text PDFHigh-quality image reconstruction techniques allow the generation of high pixel density images from a set of low-resolution micrographs. In general, these techniques consist of two main steps, namely, accurate registration, and formulation of an appropriate forward image model via some restoration method. There exist a wide variety of algorithms to cope with both stages and depending on their practical applications, some methods can outperform others, since they can be sensitive to the assumed data model, noise, drift, etc.
View Article and Find Full Text PDFSuper-resolution (SR) software-based techniques aim at generating a final image by combining several noisy frames with lower resolution from the same scene. A comparative study on high-resolution high-angle annular dark field images of InAs/GaAs QDs has been carried out in order to evaluate the performance of the SR technique. The obtained SR images present enhanced resolution and higher signal-to-noise (SNR) ratio and sharpness regarding the experimental images.
View Article and Find Full Text PDF