Publications by authors named "M P Chougaonkar"

Results on optically stimulated luminescence (OSL) in LiCaAlF6:Eu(2+) are reported. Continuous wave OSL signal as recorded using blue (470 nm) stimulation was found to be ~31% that of standard phosphor lithium magnesium phosphate. The rate of OSL depletion for standard phosphor lithium magnesium phosphate is only three times less as compared with that of LiCaAlF6:Eu(2+).

View Article and Find Full Text PDF

In view of the importance of zero-dose background (null signal) in influencing the coefficient of variation in low-dose region, a technique for the estimation of the same from composite (gross) signal is developed for CaSO4:Dy-based personnel monitoring system being used in India. The technique is based on simple analysis of glow curves (GCs) of unexposed and exposed dosemeters, evolution of trend/model for the zero-dose curves, generation of simulation protocol for individual zero-dose curves, establishment of characteristics of GCs of exposed dosemeters and finally preparation of an algorithm to segregate the components from composite signal. The technique offers the separation of real-time background and gives superior results over other method of approximation of the background.

View Article and Find Full Text PDF

Quantitative estimate of the response of ionization chamber based pocket dosimeters (DRDs) to various beta sources was performed. It has been established that the ionization chamber based pocket dosimeters do not respond to beta particles having energy (Emax)<1 MeV and same was verified using (147)Pm, (85)Kr and (204)Tl beta sources. However, for beta particles having energy >1 MeV, the DRDs exhibit measureable response and the values are ~8%, ~14% and ~27% per mSv for natural uranium, (90)Sr/(90)Y and (106)Ru/(106)Rh beta sources respectively.

View Article and Find Full Text PDF

Properties such as high optically stimulated luminescent (OSL) sensitivity, ease of preparation and dose linearity over nine decades (µGy-kGy) make LiMgPO4:Tb, B (LMP) a unique phosphor for dosimetry applications. This led to the investigation of the beta response of highly sensitive LMP-based Teflon-embedded OSL discs for personnel monitoring applications. A PTB beta secondary standard calibration setup (BSS2), which contains three beta sources viz.

View Article and Find Full Text PDF

The observational evidence for radiation-induced health effects in humans comes largely from the exposures to high doses received over short periods of time. The rate of induction of any health risk at low doses and dose rates is estimated by extrapolation from observations at high doses. Effects of low dose/low dose rate could be done by the study of populations that have been exposed to slightly above-average natural radiation doses.

View Article and Find Full Text PDF