Publications by authors named "M P Carlson"

Background And Purpose: Prior investigations have noted the presence of peritumoral hyperintense signal (a "halo") around vestibular schwannomas on postcontrast 3D T2 FLAIR images. This study evaluated this phenomenon in a cohort of patients undergoing stereotactic radiosurgery.

Materials And Methods: A retrospective review was completed of consecutive patients with presumed vestibular schwannomas undergoing stereotactic radiosurgery.

View Article and Find Full Text PDF

Cyanobacterial distributions are shaped by abiotic factors including temperature, light and nutrient availability as well as biotic factors such as grazing and viral infection. In this study, we investigated the abundances of T4-like and T7-like cyanophages and the extent of picocyanobacterial infection in the cold, high-nutrient-low-chlorophyll, sub-Antarctic waters of the southwest Pacific Ocean during austral spring. Synechococcus was the dominant picocyanobacterium, ranging from 4.

View Article and Find Full Text PDF

Objective: To analyze the use of electrical field imaging (EFI) in the detection of extracochlear electrodes in cochlear implants (CI).

Study Design: Retrospective cohort study.

Setting: Tertiary academic medical center.

View Article and Find Full Text PDF

Background: A lateral extra-articular tenodesis (LET) is increasingly being utilized to augment an anterior cruciate ligament reconstruction because it has been shown to reduce the risk of postreconstruction graft failure or recurrent rotatory instability. Various femoral fixation techniques are available, including the use of an interference screw, staple, or suture anchor.

Purpose: To determine and compare the biomechanical properties of an LET graft when using an interference screw, staple, or suture anchor for the femoral fixation for a modified Lemaire LET.

View Article and Find Full Text PDF

Purpose: To compare the performance of the photon-counting detector (PCD)-CT versus a state-of-the-art energy-integrating detector (EID)-CT to identify segments of the inferior tympanic canaliculus (Jacobsons nerve) and the mastoid canaliculus (Arnolds nerve).

Materials & Methods: Patients were prospectively recruited to undergo temporal bone CT on both EID-CT (Siemens Somatom Force) and PCD-CT (Siemens NAEOTOM Alpha) scanners under an IRB-approved protocol. Three neuroradiologists reviewed cases by consensus comparing the ability to identify the proximal, mid, and distal segments of the inferior tympanic canaliculus/Jacobsons nerve and mastoid canaliculus/Arnolds nerve on each scanner using 5-point Likert scales (with 1 indicating EID is far superior to PCD, 3 indicating they are equivalent, and 5 indicating PCD is far superior to EID).

View Article and Find Full Text PDF