Publications by authors named "M Osimani"

Purpose: To evaluate the short-term outcomes of rotator cuff repair in the presence of a greater tuberosity cyst (GTC) using a transosseous repair technique.

Methods: This study included patients who underwent arthroscopic rotator cuff tear repair with a transosseous technique and were evaluated clinically and by postoperative magnetic resonance imaging (MRI) after 1 year. The inclusion criteria were based on the results of preoperative MRI and were as follows: patients identified as having a repairable full-thickness rotator cuff tear associated with the presence of cystic changes at the tendon insertion site of the greater tuberosity, defined as a GTC involving the footprint area of the torn tendon (supraspinatus and/or infraspinatus tendons).

View Article and Find Full Text PDF

Introduction: Different surgical techniques (open and arthroscopic) have been described for the treatment of post-traumatic recurrent anterior instability. The aim of the surgery is to restore when possible, normal shoulder anatomy by repairing the underlying pathology responsible for the instability. Sometimes other surgical techniques are indicated.

View Article and Find Full Text PDF

 The aim of the present retrospective study is to describe the results obtained at 2-year follow-up by using a porcine dermis-derived collagen membrane implanted as augmentation to treat large rotator cuff tears.  Thirty-five patients in total were included according to the following criteria: large or massive rotator cuff tear, confirmed during surgery, measuring between 3 and 5 cm in width and stage 1 to 2 fatty infiltration documented at magnetic resonance imaging (MRI). Patients underwent arthroscopic repair of the cuff augmented by the implantation of a porcine dermal collagen membrane.

View Article and Find Full Text PDF

Background: Tear recurrence is considered the main complication of a rotator cuff repair. The best arthroscopic technique has not yet been established. The aim of the present study was to evaluate, from a clinical and a radiological standpoint, the all-arthroscopic transosseous rotator cuff repair with cortical lateral augmentation, performed in the setting of a revision surgery.

View Article and Find Full Text PDF

All-arthroscopic anchorless transosseous suture techniques combine the advantages of the open transosseous repair with the benefits of arthroscopic technique. However, all the techniques described until now are very complex, difficult to reproduce and associated with an increased surgical time. The authors developed a novel all-arthroscopic anchorless transosseous suture technique easy to perform and to reproduce.

View Article and Find Full Text PDF