This study evaluates the benefit of weekly delineation and peer review by a multidisciplinary team (MDT) of radiation oncologists (ROs), radiologists (RXs), and nuclear medicine (NM) physicians in defining primary and lymph node tumor volumes (GTVp and GTVn) for head and neck cancer (HNC) radiotherapy. This study includes 30 consecutive HNC patients referred for definitive curative (chemo)-radiotherapy. Imaging data including head and neck MRI, [18F]-FDG-PET and CT scan were evaluated by the MDT.
View Article and Find Full Text PDFObjective: To assess histopathological outcomes, as well as feasibility and safety of targeted microwave ablation (TMA) via the Trinity® system (KOELIS, La Tronche, France).
Patients And Methods: Prospective, single-institution, interventional Phase IIa study with an 'ablate-and-resect' design. In all, 11 patients diagnosed with localised prostate cancer (PCa) underwent TMA via the Trinity system under conscious sedation in an outpatient setting using a single transrectal TATO® 18-G antenna with different treatment regimens.
This study compares the readout-segmented echo-planar imaging (rsEPI) from the conventional single-shot EPI (ssEPI) diffusion-weighted imaging (DWI) for the discrimination of patients with clinically significant prostate cancer (csPCa) within the peripheral zone (PZ) using apparent diffusion coefficient (ADC) maps and pathology report from magnetic resonance imaging (MRI)-targeted biopsy. We queried a retrospective monocentric database of patients with targeted biopsy. csPCa patients were defined as an International Society of Urological Pathology grade group ≥ 2.
View Article and Find Full Text PDFPurpose: There is currently no consensus regarding the optimal number of multiparametric magnetic resonance imaging (MRI)-targeted biopsy (TB) cores and their spatial distribution within the MRI lesion. We aim to determine the number of TB cores and location needed to adequately detect csPCa.
Methods: We conducted a retrospective cohort study of 505 consecutive patients undergoing TB for positive MRI lesions defined by a PI-RADS score ≥ 3 between June 2016 and January 2022.
Purpose: Sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) is a black-blood 3D T1-weighted (T1w) magnetic resonance imaging (MRI) sequence that has shown robust performance for brain metastases detection. However, this could generate false positive results due to suboptimal blood signal suppression. For that reason, SPACE is used in our institution alongside a non-black-blood T1w sequence: volumetric interpolated breath-hold examination (VIBE).
View Article and Find Full Text PDF