The stability of miconazole in various diluents and polyvinyl chloride (PVC) containers was determined and the release of diethylhexyl phthalate (DEHP) from PVC bags into intravenous infusions of miconazole was measured. An injection formulation (80 ml) containing a 1% solution of miconazole with 11.5% of Cremophor EL was added to 250-ml PVC infusion bags containing 5% glucose injection or 0.
View Article and Find Full Text PDFA rapid isocratic technique was developed for the analysis of three cephalosporins: cefaloridine, cefuroxime and ceftazidime in parenteral solutions using high-performance liquid chromatography (HPLC) with UV detection and C18 column. The availability and compatibility of drugs from solutions infused via plastic infusion bags through plastic administration sets have been examined. No significant drugs loss was observed during the simulated infusions (n = 4) for 1 h using PVC infusion bags and administration sets.
View Article and Find Full Text PDFJ Clin Pharm Ther
April 1994
The availability and compatibility of drugs from solutions infused via PVC infusion bags through PVC administration sets have been examined. No significant drug loss was observed during simulated infusions using PVC infusion bags and administration sets over time periods used in hospitals (cisplatin, 2 h; carboplatin, 1 h). The stability of carboplatin was studied in 5% dextrose.
View Article and Find Full Text PDFJ Pharm Biomed Anal
January 1994
A rapid isocratic technique was developed for the analysis of cephamandole nafate and cephamandole in parenteral solutions using high-performance liquid chromatography (HPLC) with UV detection and C18 column. The availability and compatibility of drugs from solutions infused via plastic infusion bags through plastic administration sets have been examined. No significant drugs loss was observed during simulated infusions (n = 4) for 1 h using PVC infusion bags and administration sets.
View Article and Find Full Text PDFA rapid isocratic technique was developed for the analysis of four anthracyclines (doxorubicin, epirubicin, daunorubicin and pirarubicin) in parenteral solutions using high pressure liquid chromatography (HPLC) with fluorescence detection and a C18 Hypersil ODS column. The availability and compatibility of these drugs from solutions infused via PVC infusion bags through PVC administration sets have been examined. No significant drug loss was observed during simulated infusions (n = 4) for 24 h using PVC infusion bags and administration sets.
View Article and Find Full Text PDF