Publications by authors named "M L Cozzella"

Peptide receptor therapy with Lu-labelled somatostatin analogues is a promising tool in the management of patients with inoperable or metastasized neuroendocrine tumours. The aim of this work was to perform accurate activity quantification of Lu in complex anthropomorphic geometry using advanced correction algorithms. Acquisitions were performed on the higher Lu photopeak (208keV) using a Philips IRIX gamma camera provided with medium-energy collimators.

View Article and Find Full Text PDF

Over the last years (177)Lu has received considerable attention from the clinical nuclear medicine community thanks to its wide range of applications in molecular radiotherapy, especially in peptide-receptor radionuclide therapy (PRRT). In addition to short-range beta particles, (177)Lu emits low energy gamma radiation of 113keV and 208keV that allows gamma camera quantitative imaging. Despite quantitative cancer imaging in molecular radiotherapy having been proven to be a key instrument for the assessment of therapeutic response, at present no general clinically accepted quantitative imaging protocol exists and absolute quantification studies are usually based on individual initiatives.

View Article and Find Full Text PDF

In 2011 the joint research project Metrology for Radioactive Waste Management (MetroRWM)(1) of the European Metrology Research Programme (EMRP) started with a total duration of three years. Within this project, new metrological resources for the assessment of radioactive waste, including their calibration with new reference materials traceable to national standards will be developed. This paper gives a review on national, European and international strategies as basis for science-based metrological requirements in clearance and acceptance of radioactive waste.

View Article and Find Full Text PDF

The effect of radon diffusion and distribution between a (226)Ra matrix and the top air gap inside sample containers for gamma-ray spectrometry was studied. Containers filled at almost 100% or just 70% of total capacity yielded correction factors of about 7% and 20% respectively. Applying these correction factors allowed activity values calculated from (226)Ra or radon decay products to agree within 2%.

View Article and Find Full Text PDF

A (177)Lu primary standard was developed at the ENEA-INMRI in the frame of an international comparison organized by BIPM and piloted by NIST (USA). The CIEMAT/NIST method with (3)H standard source as tracer was used for standardizing a solution of (177)Lu. The activity value was compared also with the measurements of the same mother solution carried out by the 4πγ integral counting method.

View Article and Find Full Text PDF