Background: The biological effects and clinical consequences of out-of-field radiation in peripheral organs can be difficult to determine, especially for low doses (0.1 Gy-1 Gy). In recent years, Monte Carlo (MC) methods have been proposed to more accurately predict nontarget doses.
View Article and Find Full Text PDFRep Pract Oncol Radiother
July 2024
A high-energy electron accelerator is used in the treatment of patients in the so-called intraoperative electron radiotherapy (IOERT). The work aimed to present the results of the validation of a new design of an electron beam applicator for use in IOERT. A novel solution was described along with the design optimization method based on Monte Carlo simulations.
View Article and Find Full Text PDFRep Pract Oncol Radiother
July 2024
Background: The purpose was to analyse the interrelations between planning and complexity metrics and gamma passing rates (GPRs) obtained from VMAT treatments and build the forecasting models for qualitative prediction (QD) of GPRs results.
Materials And Method: 802 treatment arcs from the plans prepared for the head and neck, thorax, abdomen, and pelvic cancers were analysed. The plans were verified by portal dosimetry and analysed twice using the gamma method with 3%|2mm and 2%|2mm acceptance criteria.
Background: Clinical audits are an important tool to objectively assess clinical protocols, procedures, and processes and to detect deviations from good clinical practice. The main aim of this project is to determine adherence to a core set of consensus- based quality indicators and then to compare the institutions in order to identify best practices.
Materials And Methods: We conduct a multicentre, international clinical audit of six comprehensive cancer centres in Poland, Spain, Italy, Portugal, France, and Romania as a part of the project, known as IROCATES (Improving Quality in Radiation Oncology through Clinical Audits - Training and Education for Standardization).
Aim: In the treatment of prostate cancer with radiation therapy, the addition of a simultaneous integrated boost (SIB) to the dominant intraprostatic lesions (DIL) may improve local control. In this study, we aimed to determine the optimal radiation strategy in a phantom model of prostate cancer using volumetric modulated arc therapy for stereotactic body radiotherapy (SBRT-VMAT) with a SIB of 1-4 DILs.
Methods: We designed and printed a three-dimensional anthropomorphic phantom pelvis to simulate individual patient structures, including the prostate gland.