Purpose: This study aims to investigate inter-image intra-observer variability of macular, and optic disc (ONH) microvasculature measurements of glaucomatous and normal subjects using Swept-Source Optical Coherence Tomography Angiography (OCT-A) (OCT Topcon ImageNet 6; DRI OCT Triton, Topcon Corporation, JAPAN) - based imaging data analysis and processing with a newly made quantitative approach.
Methods: A total of 20 glaucomatous and 20 healthy eyes underwent three OCT-A scanning of the ONH and macula. Macular and papillary and peripapillary vascular networks were calculated.
Purpose: To evaluate risk factors for failure of Microshunt in glaucoma patients.
Design: Multicenter retrospective cohort study.
Methods: The study included 220 eyes from 220 consecutive glaucoma patients undergoing Microshunt implantation at six glaucoma units.
Purpose: This study aimed to describe a rare case of bilateral choroidal effusion following a XEN45 implantation.
Case Report: An 84-year-old man with primary open-angle glaucoma underwent uneventful ab interno XEN45 device implantation in the right eye. The immediate postoperative period was complicated by hypotony and serous choroidal detachment, which were treated and resolved using steroids and cycloplegic drops.