Background: Endometriosis-related pain encompassing dysmenorrhea, dyspareunia, and chronic pelvic pain, reduces the quality of life in premenopausal women. Although treatment options for endometriosis alleviate this pain, approximately one-third of women still experience pain even after receiving treatment, indicating the need for novel approaches to pain relief in those women. The Angel Touch device (AT-04) is a portable magnetic fields irradiation device that incorporates a combination of mixed alternative magnetic fields at 2 kHz and 83.
View Article and Find Full Text PDFWe have introduced a nanometer-scale non-contact displacement sensing method that relies on phase-diversity optical digital coherent detection. In our prior work, we used a conventional setup involving a 90°optical hybrid, two balanced amplified photodetectors (BAPs), and a narrow-linewidth (NLW) laser, which is complex and costly. However, in this paper, we have streamlined the system configuration by employing alternating quadrature phase modulation (AQPM) reference light, implemented using a phase modulator and a BAP.
View Article and Find Full Text PDFWe conducted a phase Ib study to examine the safety of a combination of carbon-ion RT (CIRT) with durvalumab (MEDI4736; AstraZeneca) in patients with locally advanced cervical cancer. This was an open-label, single-arm study with a modified 3 + 3 design. Patients with newly diagnosed histologically proven locally advanced cervical cancer were enrolled.
View Article and Find Full Text PDFBackground: This study aimed to examine the effect of the HMGB1 peptide on Bronchopulmonary dysplasia (BPD)-related lung injury in a mouse model.
Results: HMGB1 peptide ameliorates lung injury by suppressing the release of inflammatory cytokines and decreasing soluble collagen levels in the lungs. Single-cell RNA sequencing showed that the peptide suppressed the hyperoxia-induced inflammatory signature in macrophages and the fibrotic signature in fibroblasts.
We experimentally demonstrated and quantitatively evaluated a non-contact nanometer-displacement measurement using phase-diversity optical digital coherent detection implemented by a 90 ° optical hybrid and a narrow-linewidth probe laser without fine-tuning of optical path length difference (OPD). Combined with a comb filter, the system exhibits 99.99% linearity detection with a scale and resolution of approximately 7 nm and 2 nm respectively, as well as a wideband vibration of 5.
View Article and Find Full Text PDF