Publications by authors named "M G E Oldhoff"

Background: In acetabular fracture surgery, understanding the biomechanical behaviour of fractures and implants is beneficial for clinical decision-making about implant selection and postoperative (early) weightbearing protocols. This study outlines a novel approach for creating finite element models (FEA) from actual clinical cases. Our objectives were to (1) create a detailed semi-automatic three-dimensional FEA of a patient with a transverse posterior wall acetabular fracture and (2) biomechanically compare patient-specific implants with manually bent off-the-shelf implants.

View Article and Find Full Text PDF

Purpose: There is a debate whether corrective osteotomies of the distal radius should be performed using a 3D work-up with pre-contoured conventional implants (i.e., of-the-shelf) or patient-specific implants (i.

View Article and Find Full Text PDF

Purpose: A substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures.

Methods: In three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made.

View Article and Find Full Text PDF
Article Synopsis
  • Clinical trials indicate that baricitinib is an effective oral treatment for moderate-to-severe atopic dermatitis, though there's limited data from everyday clinical use.
  • A multicenter study assessed the treatment's effectiveness and safety over 16 weeks in 51 adults, using various outcome measurements at multiple check-ins.
  • Despite some positive outcomes, a significant number of patients (43.2%) stopped treatment due to ineffectiveness or side effects, highlighting the variability in effectiveness and safety in this patient group.
View Article and Find Full Text PDF

This study aims to develop a three-dimensional (3D) measurement for acetabular fracture displacement, determine the inter- and intra-observer variability, and correlate the measurement with clinical outcome. Three-dimensional models were created for 100 patients surgically treated for acetabular fractures. The ‘3D gap area’, the 3D surface between all the fracture fragments, was developed.

View Article and Find Full Text PDF