Pathways for microplastics to aquatic ecosystems include agricultural runoff, urban runoff, and treated or untreated wastewater. To better understand the importance of each pathway as a vector for microplastics into waterbodies and for mitigation, we sampled agricultural runoff, urban stormwater runoff, treated wastewater effluent, and the waterbodies downstream in four regions across North America: the Sacramento Delta, the Mississippi River, Lake Ontario, and Chesapeake Bay. The highest concentrations of microplastics in each pathway varied by region: agricultural runoff in the Sacramento Delta and Mississippi River, urban stormwater runoff in Lake Ontario, and treated wastewater effluent in Chesapeake Bay.
View Article and Find Full Text PDFDiel-cycling hypoxia is widespread in shallow portions of estuaries and lagoons, especially in systems with high nutrient loads resulting from human activities. Far less is known about the effects of this form of hypoxia than deeper-water seasonal or persistent low dissolved oxygen. We examined field patterns of diel-cycling hypoxia and used field and laboratory experiments to test its effects on acquisition and progression of Perkinsus marinus infections in the eastern oyster, Crassostrea virginica, as well as on oyster growth and filtration.
View Article and Find Full Text PDFUnlabelled: Articular cartilage defects have been addressed using microfracture, abrasion chondroplasty, or osteochondral grafting, but these strategies do not generate tissue that adequately recapitulates native cartilage. During the past 25 years, promising new strategies using assorted scaffolds and cell sources to induce chondrocyte expansion have emerged. We reviewed the evolution of autologous chondrocyte implantation and compared it to other cartilage repair techniques.
View Article and Find Full Text PDFClin Orthop Relat Res
May 2001
Increasing tibiofemoral articular conformity theoretically increases articular contact area and reduces contact stresses in total knee arthroplasty. Fixed-bearing knee designs possess relatively low tibiofemoral conformity, in part to allow tibiofemoral rotation without generating excessive stresses at the articulation or the implant-bone interface. This study analyzed knee kinematics of mobile-bearing designs in a closed chain dynamic knee extension model in posterior cruciate-retaining design with high- and low tibiofemoral conformity and posterior cruciate-substituting designs with and without rotational constraint.
View Article and Find Full Text PDFClin Orthop Relat Res
November 2000
Rotating platform mobile bearing knee implants allow for increased tibiofemoral articular conformity without restricting axial rotation. In the current study, the effect of rotating platform knee replacement with and without posterior cruciate ligament substitution on knee kinematics was investigated. Five knees were implanted sequentially implanted with standard (fixed) bearings and then with rotating platform prostheses, each in posterior cruciate retaining and substituting designs.
View Article and Find Full Text PDF